Page 14
93075
April 2014
4069 RT
4069 RT
Operating Instructions & Function Tests
Starting Engine from Lower Control Panel
Be sure that the upper and lower EMERGENCY STOP Switches are reset.
•
Upper Control Box:
Turn Engine Start Switch to RUN.
•
Lower Control Box:
Turn key switch to BASE.
• Press and hold the START button - release the button when the engine starts.
•
Cold Start:
press and hold the GLOW button as indicated in the Preheat table.
• With the GLOW Button held, press and hold the START Button until the engine
starts.
• Release both buttons once the engine starts.
• To protect the starter motor, power will cut off to the starter circuit when the starter
motor has run continuously for approximately 15 seconds without starting the
engine. The Starter Circuit Cutout indicator light will turn on and power to the starter
circuit will cut out for 30 seconds.
ART_2404 R1
ART_3035
ART_3189 R1
ART_3212
Preheat Table
Ambient Temperature
Preheat Time
Above 50°F (10°C)
5 Seconds
50°F to 23°F (10°C to –5°C)
10 Seconds
Below 50°F (–5°C)
20 Seconds
20 Seconds = Limit of Continuous Use