MDS 05-4457A01, Rev. A
MDS NETio Installation & Operation Guide
19
NOTE:
It will take about 5-10 seconds for the NETio modules to be
ready for operation after power is connected.
Invisible place holder
Figure 2-2. DC Power Input for NETio Modules
The modules must be used only with negative-ground
systems. Make sure the polarity of the power source
is correct. The module is protected from reverse
polarity by an internal diode and on-board fuse.
2.3 SET BASIC CONFIGURATION OF
THE NETio BASE MODULE
The following instructions give a summary of the basic settings for a
NETio Base Module.
NOTE:
All NETio configuration can be performed over-the-air
through an MDS entraNET AP. Section
2.5
explains the menu
selection needed. If this method is used, the Network Address
and Unit ID must be set in each Base Module first.
Quick Start
Step #2:
Start a HyperTerminal session to
COM1
on the Base Module, and log
into NETio. Proceed to Section
2.3.1
.
Console Terminal
Connection
The NETio Base Module is configured using a PC running Hyper Ter-
minal or a console terminal (see
Figure 2-3
). Connect a PC to the NETio
Base Module’s
COM1
port and establish a HyperTerminal session using
the following parameters: 19200 bps, 8 bits, no parity, one stop bit
(8N1), flow control disabled, VT100 emulation.
The COM1 port uses an RJ-45 connector. A DB9 to RJ-45 adaptor with
cable is supplied with each NETio Base Module.
NOTE:
The
exact
parameters given above must be used for console
terminal communication. Improper settings are a common
cause of difficulty.
+ –
PRIMARY POWER
• Nominal 13.8 Vdc @ 600 mA
(Range: 6-30 Vdc)
• Negative Ground Only
• Terminal 01 is Positive (+)
• Terminal 02 is Negative (-)
CAUTION
POSSIBLE
EQUIPMENT
DAMAGE
Содержание NETio Series
Страница 2: ......
Страница 10: ...2 MDS NETio Installation Operation Guide MDS 05 4457A01 Rev A...
Страница 22: ...14 MDS NETio Installation Operation Guide MDS 05 4457A01 Rev A...
Страница 54: ...46 MDS NETio Installation Operation Guide MDS 05 4457A01 Rev A...
Страница 68: ...60 MDS NETio Installation Operation Guide MDS 05 4457A01 Rev A...
Страница 80: ...72 MDS NETio Installation Operation Guide MDS 05 4457A01 Rev A...
Страница 84: ...76 MDS NETio Installation Operation Guide MDS 05 4457A01 Rev A...