MX-2100/2104
Installation and Operation Manual
Appendix B Alarms
Configuration Error
Messages
B-15
ERROR 59
CONFLICT BETWEEN GROUPS DESTINATION
You are selecting a time slot group that is already connected (KVF.5 and KVF.6
cards).
ERROR 60
FRAGMENTATION IN FRAME
MX-2100 can not use the full free frame space for current configuration.
ERROR 201
ML SPEEDS SHOULD BE THE SAME
The main link data rates configured on two MX-2100 connected in a link must be
equal.
ERROR 202
ML TIMINGS SHOULD BE DIFFERENT
The timing modes of two MX-2100 connected in a link must be different. In
particular, do not select the INT source at both ends of a link when KML.5, KML.6,
KML.7, or KML.8 modules are used.
ERROR 203
LOCAL AND REM SLOTS OR PARAMETERS NOT COMPATIBLE
<
parameter name>
The values assigned to the specified parameter in two MX-2100 connected in a
link are incompatible.
ERROR 204
LOCAL AND REM MUX ML MODES NOT COMPATIBLE
Incorrect main link configuration of MX-2100 connected in a link:
•
For drop & insert configuration, check that the main link mode for the
dropping MX-2100 is dual-link, and that the other units are configured for
single link.
•
For other configurations check that identical modes are used at both ends.
ERROR 205
ML-B
>
ML-A PRIORITY SHOULD EQUAL ML-A>ML-B PRIORITY
Select identical priorities for switching between the two links.
ERROR 206
FRAME ALLOCATION TYPE (AUTO-MANUAL) SHOULD BE THE SAME
The frame allocation mode of two MX-2100 connected in a link must be identical
and correct parameters must be selected:
•
For automatic allocation, check the modules in the local and remote units
have compatible offsets and parameters.
•
For normal allocation, check that connected channels have compatible
parameters.
ERROR 207
INCOMPLETE FRAME ALLOCATION
Check your manual frame bit allocation and correct.
ERROR 208
CONNECTED MUXES CANNOT BE BOTH REMOTE
Make sure that one of the MX-2100 units connected in a link is defined as local,
and the other as remote.