MX-2100/2104
Installation and Operation Manual
Appendix F Command Set Description
Commands
F-15
2. Change parameters as follows:
Bring the cursor to the beginning of the first field to be changed by
pressing the space bar.
To change the selected field, press F or B to scroll among the available
selections. When the desired selection is displayed, press the space bar
to move to the next field.
3. After the desired parameter values are selected, press ENTER
The second line of the database flip time definition screen is displayed:
HH:MM
FLIP TIME TO DATABASE 2 :
00:00
4. Define the second flipping time.
To disable the switching between the two databases, select NA for all the four
fields. You should always select NA if the switched backup database is ALTERNATE
(see DEF ML CALL command).
5. After the desired values are selected, press ENTER key to end.
MX-2100 displays the time and date fields, followed by the MX-2100
prompt.
DEF DP
Purpose
Define the communication parameters of the dial-out port.
The communication parameters depend on the KCL.2 module version:
•
For KCL.2 modules with RS-232 interfaces, this command is used to define the
communication parameters of the dial-out port, select its operating mode
(network management access port or dial-out), and when applicable, control
the use of the call-out function. The communication parameters of the dial-out
port can be different from the communication parameters of the CONTROL
port, which are selected by means of the
DEF SP
command.
•
For KCL.2 modules with Ethernet interfaces, there is only the
ROUTING_PROTOCOL
field.
Format
DEF DP
Note