MX-2100/2104
Installation and Operation Manual
Appendix F Command Set Description
Commands
F-35
The terminal displays the current value of the BERT counter of the
specified channel. The BERT count range is 0 through 65535. If the
maximum value is reached, the counter holds this value until cleared (see
next command option).
2. To display the current value of the BER counter, and then clear the counter,
type:
DSP BERT i:j /C <ENTER>
3. For continuous monitoring of the BER test running on the selected channel,
type:
DSP BERT i:j <ENTER>
4. To stop the monitoring, press BREAK or CTRL-C.
DSP CH CON
Purpose
Display the configuration of all the connected channels, i.e., all the channels for
which a main link bandwidth allocation has been defined, even if not actually
used.
Format
DSP CH CON
Use
•
Type:
DSP CH CON <ENTER>
The connected channels configuration table is displayed. A typical screen is
shown below:
ML
SPEED
CONTROL
SIGNALS
CH.
A:1 ML-A 9.6KBPS LOCAL
CH. A:2
ML-A
19.2KBPS
LOCAL
.
.
.
.
.
.
.
.
.
.
.
.
COMP A:*
ML-B
9.6KBPS
N/A
The display fields are explained below:
•
CH i:j
- Lists the channel identification.
For modules for which there are no configurable channels, e.g., for KLS.2
modules, only the composite data can be displayed; in this case, the display
shows COMP i:*.
•
ML
- Indicates the main link to which the channel is currently connected.
•
SPEED
- Shows the channel data rate, in kbps.