MX-2100/2104
Installation and Operation Manual
Appendix B Alarms
Alarm Messages
B-7
Table B-1. LCD Alarm Messages (Cont.)
Code Message - LCD
Message - Terminal
Alarm
Type
Description
59
EXE ERR RAT
EXECIVE ERR RATIO,
SLOT i
State
The error rate detected on the frame
synchronization bits is high (as defined
by ITU-T Rec. G.732), and may indicate
hardware problems or defective
connections
60
CRC-4 ERROR
CRC-4 ERROR, SLOT i
Event
The main link module reports the
detection of a CRC error
61
B.R.G FAIL
SFIFO B.R.G FAIL,
SLOT i
State
The baud rate generator of the specified
module failed. Replace the module
62
SFIFO SLIP
SFIFO SLIP, SLOT i
Event
The KML.7 module installed in the
specified slot reports that a slip occurred
in the SFIFO
63
INT CLK USE
INTERNAL CLOCK IN
USE, SLOT i
State
The internal oscillator has been selected
as a timing reference sources, as a result
of simultaneous failure of both the
master and fallback clock sources
64
DP – DIAL FAIL
DP CYCLE DIAL FAILED Event
The dial-out cycle failed, and the redial
attempts stopped until a new alarm
reported
65
DP PRI CALL FAIL
DP PRIMARY CALL
FAILED
Event
The call setup attempts to the primary
dial-out directory number failed
66
DP ALT.CALL FAIL
DP ALTERNATE CALL
FAILED
Event
The call setup attempts to the alternate
dial-out directory number failed
67
FRAMER CARD FAIL FRAMER CARD FAILED State
The master KVF.5 module failed
68
MGMT P IS LOP ML-i MGMT PORT IS
LOOPED ML-i
State
Management port is looped and cannot
communicate with the remote MX-2100
due to loopback activation on main link
A or B
69
MGMT DOWN ML-i MGMT PORT IS DOWN
ML-i
State
MX-2100 cannot communicate to the
remote MX-2100 via in-band
management channel in main link A
or B
70
AGETS SAM NET
AGENTS WITH SAME
NAME IN NET
Event
There is an agent with the same name in
the network
71
TAK SNMP MMI
CONTOLR TAKEN BY
SNMP MMI
Event
MX-2100 is controlled by SNMP
management station
72
TAK TERM MMI
CONTOLR TAKEN BY
TERM MMI
Event
MX-2100 is controlled by ASCII terminal
73
TAK LCD MMI
CONTOLR TAKEN BY
LCD MMI
Event
MX-2100 is controlled by LCD