Measurement Operation

First check on 9V battery, then turn rotary switch to
the measuring position. If the low battery, “       ” sign.
will be displayed on LCD panel. Nearly to “       ” sign
on the meter front panel terminal input which alarm
not exceed the testing voltage and current input value
limitation.

A. DC/ AC Voltage Measurement 

6HH¿JXUH

¿JXU

e

. In each range, the meter has an input impedance

of

This loading effect can cause measurement

errors in high impedance circuits. If the circuit
impedance is less than or equal to

the error is

QHJOLJLEOHRUOHVV

2. Press SELECT to switch AC or DC voltage
measurement.
3. The display value of AC measurement is effective
value of sine wave( average

YDOXH

4. The

mV AC range can obtain only under

manual mode.
Note:
To avoid possibly damages to the meter, please do

QRWDWWHPSWWRLQSXWKLJKHUWKDQ

V.

To avoid electrical shock, please pay attention during
the high voltage measurement.

B. Capacitor Measurement

87%RQO

y

¿JXUH

¿JXUH

. The

0

eter will display a

¿

xed value as below which

is the

0

eter internal fixed distributed capacitance

value. To ensure accuracy when measuring a small
value of capacitance, the tested value must subtract
this value, REL mode can help on that.
2. It is normal to take several seconds to obtain a
stable reading when testing a high value capacitor.
3. To avoid possibly damages to the meter, please do
not attempt to input higher than

9

DC and 33V rms

AC.

7.

%

attery in meter: 9V

F22 or NEDA

4 or

,(&/5
'H¿FLHQF\RI%XLOWLQ%DWWHU\/&'GLVSOD\³´
3URGXFWVL]HPPîPPîPP
1HW

Weight:

$ERXWJEDWWHU\LQFOXGH

&RQIRUP&(

Button function and auto power off

HOLD

 button

Press HOLD to enter and exit hold mode in any mode 
except frequency measurement. 
2.

SELECT

 button

Press

SELECT

button to select the alternate

functions including AC/DC voltage, AC/DC current,
auto and manual ranging, frequency and duty cycle.
Used as REL function button under resistance
measurement.
3. AUTO POWER OFF
To preserve battery life, the

0HWHU

automatically goes

into a “sleep” mode if you do not press any button for
around

5 minutes. The

0

eter can be activated by

pressing any button, then returns to the display for
the function selected previously. To disable the sleep
mode function, press SELECT button while turning on
the meter.

%8==(5

The buzzer phonate go with every time button be
effectual pressed. When the meter will auto power off
in

minutes the buzzer beeps 5 times.

%HIRUH

power

off there will be a long time buzzer beeps.

87$%&'2SHUDWLQJ0DQXDO

UT136A/B/C/D

Handheld Digital Multimeter

                  Operating Manual

Safety Information

0

eter UT

$%

/C/D complies with the standard

IEC/EN

, in pollution degree 2, overvoltage

category (CAT II

V

and double insulation. Use

the meter only as

VSHFL¿HG

in this operating manual,

otherwise the protection provided by the meter may
be impaired.

.

%

efore using the meter inspect the case. Do not

use the meter if it is damaged or the case (or part
of the

FDVH

is removed. Look for cracks or missing

plastic. Pay attention to the insulation around the
connections.
2. Inspect the test leads for damaged insulation or
exposed metal. Replace damaged test leads with
identical model number or electrical specifications
before using the meter.
3. Replace the battery as soon as the battery
indicator “        ” Appears. With a low battery, the
meter might produce false readings that can lead to
electric shock and personal injury.
4. When measurement is on / off against the correct
testing position.
5. Do not apply more that the rated voltage, as
marked on the meter in order to avoid possible
electric shock or personal injury and avoid possible
damage to the meter.

. Do not change the measuring range during the

testing as it causes to damage the meter.
7. When each measurement has been completed,
disconnect between the test leads and the circuit
under test connection, then turn the meter power
off and remove the test leads away form the input
terminals of the meter.
8. When the meter working at an effective voltage
over

V in DC and 3

Vrms in AC, special care

should be taken.
9. Do not use or store the meter in an environment of
high temperature and humidity. The performance of
the meter may deteriorate after dampened.

. The internal circuit of the meter shall not be

altered at will to avoid damage of the meter and any
accident.

. Soft cloth and mild detergent should be used to

clean the surface of the meter when servicing. No
abrasive and solvent should be used to prevent the
surface of the meter from corrosion, damage and
accident.

International Electrical Symbols

Double Insulated

Grounding

'H¿FLHQF\RI%XLOWLQ%DWWHU\

W

DUQLQJ5HIHUWRWKH2SHUDWLQJ0DQXDO

$&$OWHUQDWLQJ&XUUHQW

'&'LUHFW&XUUHQW

Conforms to Standards of European Union

2YHUDOO6SHFL¿FDWLRQ

.

0

aximum voltage between any terminals and

grounding. Refer to different range input protection
voltage.
2.

A terminal:

A H

9

Fast Type Ceramic Fuse

ĭ[PP

3. mA terminal:

.5 A H

V Fast Type Ceramic

)XVHĭ[PP
0D[LPXPGLVSOD\
2SHUDWLQJWHPSHUDWXUH

ć̚

ć˄

32

̧̚

̧˅

  

Relative Humidity

:

ć̚

ć

EHORZ”

,

ć̚

ć

”

6WRULQJWHPSHUDWXUH

ć̚

ć

̧̚

̧

5.  Electromagnetism:
Under

V/m emission:

%

est Total Accuracy= Spec

L¿

c

$FFXUDF\0HDVXUHPHQW
2YHU9PHPLVVLRQGRQRWKDYHDQ\VSHFL¿FLQGH[
(OHYDWLRQ

:

̚

P

C. DC/AC Current Measurement

VHH¿JXUH

¿JXUH

.

Press SELECT to switch AC or DC current measurement

2.Turn off power to the circuit before the connection
between the test leads across with the object being
measured.
3. Selecting the correct terminal input and turn the
rotary switch to select the measuring function.  In case
of no any idea on the value input of the current, just
simply test from the high value to low one.
4.

Fuses are located on mA and

A terminal input.

Never attempt the test lead connect to any circuits
especially on the power supply terminal and may be
hurt.

5. For the safety purpose, less than

seconds is

for each measurement duration and keep

minutes

duration for next measurement during the current
measurement over 5A.

D. Resistance Measurement

VHH¿JXUH

¿JXUH

. The LCD displays “OL” indicating open

circuit for

the tested resistor or the resistor value is higher than
the maximum range of the meter.
2. To maintain the resistance measurement accuracy,
discount circuit power and discharge all the high
voltage capacitors during the measuring resistance.
3. The test leads cause

.

ȍ

~

.2

ȍ

resistance

variation during the measurement, In order to obtain
precision readings in

ORZUHV

istance measurement.

Need to make the short circuit on the test leads and
mark the measurement value which show on LCD
display. Then deduct this variation value on the
measurement value which come the meter.
4. If

ȍ

reading with shortened test leads is not less

than or equal to

.5

ȍ

, check for loose test leads,

incorrect function selection or others.
5. For

KLJKUH

sistance measurement greater than

it is normal to take several seconds to obtain a

stable reading with short test leads for measurement.

Do not input higher than DC

9

and AC

9

rms

voltage to prevent any damage and accident.

E. Diodes Measurement 

VHH¿JXUH

¿JXUH

Disconnect circuit power and discharge all the high

voltage capacitors before measuring resistance.
2. Place the red test lead on the component’s anode
and place the back test lead on the component’s
cathode, a good diode should still produce a forward
voltage drop reading of

~

mV. The LCD

displays “OL” indicating

RSHQ

circuit for the tested

diodes or the testing the diodes with polarity.
3.

7KHRSHQFLUFXLWIRUGLRGHVLV

V.

4. Do not input higher than DC

9

and AC

9

rms

voltage to prevent any damage and accident. 

F. Continuity Measurement

VHH¿JXUH