18
RD6
ATTACHMENT 1
–
Special function
Value
Application
Note
0
no special function (normal output)
1
flash symetric
time base (0,1s / value)
2
flash asymetric short ON (1:4)
time base (0,1s / Value) is for the
long value
3
flash a symetric long ON (4:1)
4
Photographer flash
time base (0,25s / value)
5
monoflop (automatic switch off)
time base (0,1s / value)
6
switch on delayed
time base (0,1s / value)
7
firebox
8
TV flickering
9
petroleum flickering
10
flourescent tube
11
defective flourescent tube
12
alternating flash to paired output
in combination with second output
(e.g. A1 & A2, A3 & A4)
13
US strobelight
14
US double strobelight
15
US marslight
time base (0,1s / value)
16
US ditch light
in combination with second output
(e.g. A1 & A2, A3 & A4), 1
st
output
normal light, 2
nd
ditch light function
17
sodium lamp
18
welding light
use with blue led
+32
add switch off delayed
add value to function
+64
add switch on delayed
add value to function
+128
invers
add value to function