17
RD6
CV-Table
S = Default, L = Loco address, S = Switch address, LS = Loco and switch address usable
20
A1 switch address high
0
S
1
–
2048
switch output 1, if address smaller 256 easy
programm CV21 = desired address!
21
A1 switch address low
1
S
22
A1 function key for loco
command (F0
–
F68)
1
L
0
–
68
only active, if cv14 = 0. Control over CV1 loco
address and f-keys
23
A1 special function
0
S
see attachment 1
24
A1 time for special function
5
S
1
–
255
time base (0,1s / value)
25
A2 switch address high
0
S
1
–
2048
switch output 2, if address smaller 256 easy
programm CV26 = desired address!
26
A2 switch address low
2
S
27
A2 function key for loco
command (F0
–
F68)
2
L
0
–
68
only active, if cv14 = 0. Control over CV1 loco
address and f-keys
28
A2 special function
0
LS
see attachment 1
29
A2 time for special function
5
LS
1
–
255
time base (0,1s / value)
30
A3 switch address high
0
S
1
–
2048
switch output 3, if address smaller 256 easy
programm CV31 = desired address!
31
A3 switch address low
3
S
32
A3 function key for loco
command (F0
–
F68)
3
S
0
–
68
only active, if cv14 = 0. Control over CV1 loco
address and f-keys
33
A3 special function
0
LS
see attachment 1
34
A3 time for special function
5
LS
1
–
255
time base (0,1s / value)
35
A4 switch address high
0
S
1
–
2048
switch output 4, if address smaller 256 easy
programm CV36 = desired address!
36
A4 switch address low
1
S
37
A4 function key for loco
command (F0
–
F68)
4
L
0
–
68
only active, if cv14 = 0. Control over CV1 loco
address and f-keys
38
A4 special function
0
LS
see attachment 1
39
A4 time for special function
5
LS
1
–
255
time base (0,1s / value)
40
A5 switch address high
0
S
1
–
2048
switch output 5, if address smaller 256 easy
programm CV41 = desired address!
41
A5 switch address low
2
S
42
A5 function key for loco
command (F0
–
F68)
5
L
0
–
68
only active, if cv14 = 0. Control over CV1 loco
address and f-keys
43
A5 special function
0
LS
see attachment 1
44
A5 time for special function
5
LS
1
–
255
time base (0,1s / value)
45
A6 switch address high
0
S
1
–
2048
switch output 6, if address smaller 256 easy
programm CV46 = desired address!
46
A6 switch address low
3
S
47
A6 function key for loco
command (F0
–
F68)
6
L
0
–
68
only active, if cv14 = 0. Control over CV1 loco
address and f-keys
48
A6 special function
0
LS
see attachment 1
49
A6 time for special function
5
LS
1
–
255
time base (0,1s / value)