47
14-ALARMS
Technical Dept. - All rights reserved - Reproduction is prohibited
A13
Electronic control unit overheating
The structure is too hot because the product has been
used for too long at the maximum power or there is
poor ventilation. When the stove is sufficiently cold,
press button B on the control panel or OFF on the remote
control to cancel alarm A13. Once the alarm is cancelled,
the product can be switched on normally.
A14
Faulty air flow rate sensor
This alarm does not block the stove, just a warning is
displayed. Contact an authorised service centre to have
the component replaced.
SER
Routine maintenance warning after 2000
hours of operation
When this flashing message appears upon start-up
it indicates that the preset operating hours before
maintenance is due have elapsed and that an MCZ
qualified technician must be contacted for maintenance.
Exiting the alarm conditions
Follow the procedure described below to restore normal stove operation after an alarm has been triggered:
• Put selector D on the rear emergency panel on OFF for a few seconds, until the 3 digit alarm identity code disappears. The red LED
stops flashing and the sound signal is silenced by performing the steps below.
• Put selector D back in the REMOTE position, to control the operation of the stove via the remote control.
• Switch off the remote control and switch it on again if one wants to restart the stove.