background image

x

H

25

5-MUSA STOVE ASSEMBLY

Technical Dept. - All rights reserved - Reproduction is prohibited

•  Remove the other two screws “x” from under the front top “G”.

The top “H” can then be lifted and placed on the ground until the steel sides will be installed.

Содержание MUSA 2.0

Страница 1: ...INSTALLATION GUIDE EN PELLET STOVE MUSA 2 0 Comfort Air 14 Instructions in English...

Страница 2: ...SSEMBLY 22 6 REMOVING THE BACK FOR MAINTENANCE 28 7 CONNECTIONS TO ADDITIONAL DEVICES 29 8 ELECTRICAL CONNECTION 31 9 LOADING THE PELLETS 32 10 FIRST START UP 33 11 REMOTE CONTROL MAX 35 12 EMERGENCY...

Страница 3: ...for the system installed By system one means Stove Chimney Air inlet REVISIONSTOTHE PUBLICATION The content of this manual is strictly technical and the property of MCZ Group Spa No part of this manua...

Страница 4: ...hopper The instructions provided in this manual must always be complied with to ensure the product and any electronic appliances connected to it are used correctly and accidents are prevented This ap...

Страница 5: ...duct with the door open or the glass broken The doors covers on the appliance must remain closed when it is not used The product must be powered by an electrical system that is equipped with an effect...

Страница 6: ...he surface on which the weight of the product willrestandprovidesuitableinsulationifitismadeofflammablematerial e g wood fitted carpet or plastic Live electrical parts only power the product once it h...

Страница 7: ...attested by a document to serve as proof of purchase invoice and or receipt that shows the name of the vendor and the date on which the purchase was made forwarding of the completed certificate of gu...

Страница 8: ...maintenance performed by an authorised technician or qualified personnel will result in the loss of the warranty Also excluded from this guarantee are parts subject to normal wear such as gaskets glas...

Страница 9: ...ut authorisation Allpartsmustbereplacedwithoriginalspareparts WARNINGS FORTHE CORRECT DISPOSAL OFTHE PRODUCT The owner is the sole party responsible for demolishing and disposing of the product This m...

Страница 10: ...To ensure good combustion the pellets must be stored in a dry place and protected from dirt Pellets are usually supplied in 15 kg bags therefore storing them is very convenient Good quality pellets gu...

Страница 11: ...he integrity of the home The installation of the appliance must ensure easy access to clean the appliance itself the smoke outlet pipes and the flue It is forbidden to install the stove in rooms with...

Страница 12: ...in force SMOKE FLUE The flue or chimney is of great importance for the proper operation of a solid fuel burning heating appliance with natural draught as modern heating appliances have high efficiency...

Страница 13: ...d reduce smokecooling Itshouldbeseparatedfromcombustibleorflammablematerialswithanairgaporinsulatingmaterials checkthedistance specified by the manufacturer of the fireplace according to EN1443 The ch...

Страница 14: ...rectly dimensioned in accordance with the general method of calculation of UNI EN13384 1 or other proven efficiency methods Below is a list of some flues available on the market Steel chimney AISI 316...

Страница 15: ...of the system CHIMNEY The chimney is a crucial element for the heating appliance to work properly we recommend a wind proof chimney A see Figure 7 The area of the opening for smoke extraction must be...

Страница 16: ...e a depression in the room Make sure that with all appliances on the pressure drop between the room and the outside does not exceed the value of 4 Pa also for Oyster appliances if the combustion air h...

Страница 17: ...1 accessible 90 bend 6 5 metres Maximum length with 3 accessible 90 bends 4 5 metres Maximum number of accessible 90 bends 3 Horizontal sections minimum incline 3 4 metres Use smoke ducts with a diam...

Страница 18: ...ar the minimum safety distances from combustible materials The previous rules also apply for holes made in walls 2 Oldflue minimumpipe 100mmwiththeinclusionof an external access door for chimney clean...

Страница 19: ...16 1094 550 60 50 60 80 480 303 200 180 195 180 275 17 3 DRAWINGS ANDTECHNICAL FEATURES Technical Dept All rights reserved Reproduction is prohibited DRAWINGS AND CHARACTERISTICS DIMENSIONS OF MUSA 2...

Страница 20: ...and size 3 40 mm Pellet hourly consumption Min 0 9 kg h Max 3 3 kg h Autonomy At min 30 h At max 8 h Heatable volume m3 301 40 344 35 401 30 Combustion air inlet 50 mm Smoke outlet 80 mm Air intlet 80...

Страница 21: ...over and handle the majolica parts with care The stoves are delivered in a single package with ceramic panels or steel sides packaged together with the structure and placed on top or at the side Open...

Страница 22: ...4 UNPACKING Remove the Suite Club Musa stoves from the pallet by removing the two screws u and the plate s from the stove foot There are four brackets s REMOVING THE FASTENING BRACKETS SUITE CLUB MUSA...

Страница 23: ...the connecting pipe If the stove needs to be connected to an outlet pipe which goes through the rear wall to connect to the flue take utmost care to make sure that the joint is not forced If the stove...

Страница 24: ...ricalparts onlypowertheproductonceithasbeenfullyassembled The Musa stove is supplied with the steel sides separate and the cast iron top already mounted on the structure Therefore assemble the sides b...

Страница 25: ...k 23 5 MUSA STOVE ASSEMBLY Technical Dept All rights reserved Reproduction is prohibited Remove the top as follows lift the hopper cover remove the two screws k...

Страница 26: ...G 24 5 MUSA STOVE ASSEMBLY Remove the front top G...

Страница 27: ...SSEMBLY Technical Dept All rights reserved Reproduction is prohibited Remove the other two screws x from under the front top G The top H can then be lifted and placed on the ground until the steel sid...

Страница 28: ...nsert the two hooks y on the structure of the stove in holes j at the bottom of the side secure the side above to the stove using two screws o Once assembly of the two sides is completed position the...

Страница 29: ...MBLY Technical Dept All rights reserved Reproduction is prohibited Thensecurethetop H withthetwoscrews x tothestructure positiontheuppertop G andsecureitwiththetwoscrews k andclose the hopper cover se...

Страница 30: ...ust be performed on a component of the stove the rear panel can be removed if the distances from the walls allow it otherwise the maintenance can be performed by removing the side of the stove To remo...

Страница 31: ...b Wi Fi Interface N using the holes on the back of the product and follow the instructions on the product chosen USB SOCKET ThereisaUSBsocketonthebackofthestove ifasoftwareupdateisrequired theceramic...

Страница 32: ...he two rear vents see image below Remove the vents as follows remove the two screws V extract vent B remove grid G channel the air If you do not wish to channel the air the hot air may be let out thro...

Страница 33: ...nyotherpartofthestove STOVE POWER SUPPLY After connecting the power cable to the back of the stove turn the switch to I or ON The stove is then powered Thereisafuseboxalsointheswitchblocknexttothepowe...

Страница 34: ...f Whenloading donotletthepelletbagcomeintocontactwithhotsurfaces Neverremovetheprotectiongridinsidethehopper No other type of fuel other than pellets is to be inserted into the hopper in compliance wi...

Страница 35: ...the product can be operated in safe mode via the rear emergency panel In this configuration the stove can only operate in manual mode and with the possibility to choose between 3 power levels SWITCHI...

Страница 36: ...as mentioned air the room The smoke and smell of paint will disappear after about an hour of operation however they are not harmful in any case The boiler will be subject to expansion and contraction...

Страница 37: ...the battery compartment cover When the remote control is powered it automatically prompts to set the time The remote control has a special icon on the display to indicate when the batteries are almost...

Страница 38: ...tart to flash Confirm this data to exit the settings NOTE each time the remote control is powered the time is reset and the display automatically enters the time setting mode C F setting Only with the...

Страница 39: ...lly set to a minimum when the set temperature value is reached if the bars are all full the stove is on flame power 5 if only one bar is full the stove is on flame power 1 If the ventilation is MANUAL...

Страница 40: ...by until the room temperature drops 2 degrees below the desired temperature and in any case for at least 5 minutes from the last shutdown The product is then switched on again Figure 4 If the room is...

Страница 41: ...n 5 ventilation remains set on 3 for silent operation as it is in automatic mode In products with 2 or 3 room fans comfort air models via key D one can scroll and set the speed of the individual fans...

Страница 42: ...confirm NO AIR FUNCTION SF The NO AIR function allows the stove to operate at the minimum power throughout the night with no room ventilation This function is only available in AUTO and MAN mode not i...

Страница 43: ...ime slots display By pressing key D at any time one exits the time slot editing mode saving all variations confirmed with key E up to that time and one goes back to the time slot display condition Whi...

Страница 44: ...wing functions OFF Stove switched off manually without remote control REMOTE Stove controlled exclusively from the remote control ON Stove switched on manually without the remote control E Three posit...

Страница 45: ...ted ASSEMBLY OF CONTROL PANEL ANTENNA Take the antenna A from the bag containing the instructions Screw the antenna A clockwise on screw V near the control panel until the mobile part is positioned up...

Страница 46: ...fan stops the circuit board promptly blocks the supply of pellets and the alarm is displayed GEAR MOTOR BREAKAGE If the gear motor stops the product switches off and the relative alarm is signalled TE...

Страница 47: ...er being empty Enable the function as follows Set the first selector to OFF Set the second selector to MED Make sure that OFF appears on the display because this function can only be activated with th...

Страница 48: ...reshold The structure overheats due to reduced heat dissipation The structure is too hot because the product has been used for too long at the maximum power or there is poor ventilation When the produ...

Страница 49: ...Routine maintenance warning after 2000 hours of operation When this flashing message appears upon start up it indicates that the preset operating hours before maintenance is due have elapsed and that...

Страница 50: ...on When the product is sufficiently cold press button B on the control panel or OFF on the remote control to cancel alarm A03 Once the alarm is cancelled the product can be switched on normally If A04...

Страница 51: ...t is fundamental to guarantee that the product is installed in compliance with standards in force Furthermore it is of the utmost importance to respect the following simple rules Every time the brazie...

Страница 52: ...uality pellets DAILY ORWEEKLY CLEANING PERFORMED BYTHE USER Brazier cleaning Before ignition always clean the T brazier and remove any ash or incrustation from it that might obstruct the air flow hole...

Страница 53: ...eramic glass with a dry brush or if it is very dirty spray a little specific detergent and clean with a cloth ATTENTION Do not use abrasive products and do not spray the glass cleaning product on the...

Страница 54: ...byanauthorisedandskilledtechniciansothateven thesealscanbereplaced CLEANINGTHE EXCHANGER Open the stove door remove the brazier and the ash pan Then remove the inside of the firebox starting from the...

Страница 55: ...ovethetop A andthefirstceramic C ontherightandleftsideofthestove seethespecificpagesinthismanual toremovetheceramics Thenremovethetwoscrews r theseal S andtheplate T andcleanthelateralwallsofthefirebo...

Страница 56: ...zontalsectionsofthesmokeduct For information on periodically cleaning the flue contact a skilled chimney sweep Check the seal of the ceramic fibre gaskets on the door of the stove If necessary order n...

Страница 57: ...closureensuresacorrectsealingaction withthe papersheet test andthatwhenthedoorisclosed theclosingblock X in the figure does not protrude from the sheet metal to which it is secured For some products i...

Страница 58: ...fusebox cover with a screwdriver and replace the fuses if necessary 3 15 A delayed seek assistance from an authorised and qualified technician CHECKINGTHE INTERNAL COMPONENTS ATTENTION The internal el...

Страница 59: ...he hopper with pellets The pellets are not fed See the previous anomaly The pellet temperature safety probe has been triggered Let the product cool down restore the thermostat until the lockout is off...

Страница 60: ...cleaning of the combustion chamber and the smoke duct Check the condition of the door gaskets Damp or unsuitable pellets Change the type of pellets Faulty smoke evacuation motor Check the motor and r...

Страница 61: ...temperature probe Checktheprobeandreplaceitifnecessary Faulty or malfunctioning control panel Check the panel and replace if necessary The product does not switch on No power supply Check that the pl...

Страница 62: ...CER 4 SMOKETEMPERATURE PROBE 5 SOFTWARE UPDATE USB 6 MODBUS COMMUNICATION FOR MODEM WI FI ETC 7 EMERGENCY PANEL 8 HOPPER OVERLOAD CUT OUT 9 AIR FAN 1 10 GEAR MOTOR 11 SMOKE FAN 12 SPARK PLUG 13 SWITCH...

Страница 63: ......

Страница 64: ...16 12 2015 REV 4 8901517400 MCZ GROUP S p A Via La Croce n 8 33074Vigonovo di Fontanafredda PN ITALY Telephone 39 0434 599599 r a Fax 39 0434 599598 Internet www mcz it e mail mcz mcz it...

Отзывы: