2 - INSTALLATION INSTRUCTIONS

FOREWORD

The installation position must be chosen according to the room, to the smoke extraction system, to the chimney flue. Check with local 

authorities whether there are any restrictive regulations in force regarding the combustion air inlet, the smoke outlet system, the 

flue or the chimney cap. The manufacturer declines all responsibility in the event of installations that do not comply with the laws in 

force, incorrect room air exchange, electrical connection non-compliant with the standards and inappropriate use of the appliance. The 

installation must be carried out by a qualified technician, who must issue a declaration of conformity of the system to the purchaser and 

will assume full responsibility for final installation and consequent good operation of the product. 

In particular one must ensure that:

•  there is a suitable combustion air inlet and smoke outlet in compliance with the type of product installed

•  other stoves or devices installed do not cause depression in the room where the product is installed (for sealed appliances only, a 

maximum of 15 Pa of depression in the room is allowed)

•  when the product is switched on there is no reflux of smoke in the room

•  fumes extraction takes place in total safety (sizing, smoke seal, distances from flammable materials..).

We especially recommend to check the data tags of the flue for the safety distances that must be observed in presence 

of combustible materials and the type of insulating material to be used. These indications must be followed strictly to 

prevent serious harm to people and the integrity of the home.

 The installation of the appliance must ensure easy access to 

clean the appliance itself, the smoke outlet pipes and the flue. 

It is forbidden to install the stove in rooms with a fire hazard. 

Installation in studio flats, bedrooms and bathrooms is only allowed with sealed or closed appliances equipped with 

suitable combustion air ducting directly outside. Always maintain adequate distance and protection in order to prevent 

the product from coming into contact with water.

In the event there are several appliances installed, the external air inlet must be sized accordingly.

MINIMUM DISTANCES

It is recommended to install the stove detached from any walls and/or furniture, with a minimum  clearance to allow effective aeration of 

the appliance and a good distribution of heat in the room.Observe distances from flammable or heat-sensitive objects (sofas, furniture, 

wood panelling, etc..) as specified below. The front distance from flammable materials must be at least as set out in the product’s technical 

data table.

If particularly delicate objects are present, such as furniture, curtains or sofas, increase the stove clearance accordingly.

If the floor is made of wood, it is recommended to fit a floor protection sheet in compliance with the Standards in 

force in the country of installation.

FLUX HYDRO

Distance from flammable material (see p.18)

back = 1 cm

side = 2 cm (MIN. 30 cm to open the door)

If the floor is made of combustible material, it is recommended to use protection made of non-combustible material (steel, glass...) that 

also protects the front from falling combusted material during cleaning operations.

The appliance must be installed on a floor with adequate load capacity.

If the existing construction does not meet this requirement, one must take appropriate measures (for example a load distribution plate).

Содержание FLUX HYDRO

Страница 1: ...INSTALLATION GUIDE EN Instructions in English PELLET STOVE FLUX HYDRO PART 1 REGULATIONS AND ASSEMBLY...

Страница 2: ...TS II INTRODUCTION 1 1 WARNINGS AND WARRANTY CONDITIONS 2 2 INSTALLATION INSTRUCTIONS 8 3 DRAWINGS AND TECHNICAL CHARACTERISTICS 18 4 UNPACKING 20 5 POSITIONING 21 6 PANEL REMOVAL 24 7 HYDRAULIC CONNE...

Страница 3: ...talled By system one means Stove Chimney Air inlet REVISIONSTOTHE PUBLICATION The content of this manual is strictly technical and the property of MCZ Group Spa No part of this manual may be translate...

Страница 4: ...omplied with to ensure the product and any electronic appliances connected to it are used correctly and accidents are prevented This appliance can be used by children aged from 8 years and above and p...

Страница 5: ...ccumulated unburned pellets in the burner after each failed start up must beremovedbeforelightingagain Checkthattheburneriscleanandpositioned properly before lighting again Shut the stove down in the...

Страница 6: ...en contact the competent authorities The product and the cladding must be stored in a dry place and must not be exposed to weathering It is recommended not to remove the feet that support the product...

Страница 7: ...g page for a period of 2 two years from the date of purchase attested by a document to serve as proof of purchase invoice and or receipt that shows the name of the vendor and the date on which the pur...

Страница 8: ...d on an annual basis by an authorised technician or qualified personnel will result in the loss of the warranty Also excluded from this guarantee are parts subject to normal wear such as gaskets glass...

Страница 9: ...ut authorisation Allpartsmustbereplacedwithoriginalspareparts WARNINGS FORTHE CORRECT DISPOSAL OFTHE PRODUCT The owner is the sole party responsible for demolishing and disposing of the product This m...

Страница 10: ...rolandmaintenance forthermochemical power at the firebox lower than 35kW UNI TS 11278 general technical regulation for the choice of smoke duct flue UNI 10847 2000 Smoke extractor systems for liquid a...

Страница 11: ...bout 18 months of seasoning whereas that of pellets is 4 9 kW kg To ensure good combustion the pellets must be stored in a dry place and protected from dirt Pellets are usually supplied in 15 kg bags...

Страница 12: ...integrity of the home The installation of the appliance must ensure easy access to clean the appliance itself the smoke outlet pipes and the flue It is forbidden to install the stove in rooms with a f...

Страница 13: ...operation of a solid fuel burning heating appliance with natural draught as modern heating appliances have high efficiency with cooler flue gasses and consequently less draught it is therefore essent...

Страница 14: ...uldbeseparatedfromcombustibleorflammablematerialswithanairgaporinsulatingmaterials checkthedistance specified by the manufacturer of the fireplace according to EN1443 The chimney opening must be in th...

Страница 15: ...ordancewiththegeneralmethodofcalculationofUNIEN13384 1or other proven efficiency methods Below is a list of some flues available on the market Steel chimney AISI 316 with doublechamberinsulatedwith ce...

Страница 16: ...a crucial element for the heating appliance to work properly we recommend a wind proof chimney A see Figure 7 The area of the opening for smoke extraction must be at least double the cross section of...

Страница 17: ...s for example electric fan for stale air extraction kitchen hood other stoves etc which could cause cause depression intheroom Onemustverifythat withalltheequipmenton thepressuredropbetweentheroomandt...

Страница 18: ...stallation and verify that it is compatible with the product and installation characteristics The temperature class of the smoke duct must exceed operating temperatures of the appliance It is prohibit...

Страница 19: ...ct the data tags on the flue in particular the minimum safety distances from combustible materials The previous rules also apply for holes made in walls 2 Oldflue minimumpipe 100mmwiththeinclusionof a...

Страница 20: ...18 279 8 1111 83 709 197 357 73 80 48 989 1119 973 279 989 75 99 3 DRAWINGS ANDTECHNICAL CHARACTERISTICS DRAWINGS AND CHARACTERISTICS FLUX HYDRO DIMENSIONS dimensions in mm...

Страница 21: ...er 0 02 mbar 2 Pa Smoke mass 9 8 g sec Hopper capacity 33 litres Type of pellet fuel Pellet diameter 6 8 mm and size 3 40 mm Pellet hourly consumption Min 1 kg h Max 3 3 kg h Autonomy At min 21 h At m...

Страница 22: ...osenarea makingsureitcomplieswiththerequirements Thestovebodyorunitmustalwaysbekeptinavertical positionwhenhandled andhandledusingcartsonly Payparticularattentiontothedooranditsglass protectingthemfro...

Страница 23: ...ements for installation the minimum clearance in front of the product to allow suitable access for cleaning maintenance etc must be 400 mm the minimum permissible distance between the back of the prod...

Страница 24: ...MENT The underside of the stove is fitted with adjustable feet Use a spanner to unscrew the feet to adjust the length and make the structure stable TURNTHEFEETCLOCKWISETOLOWERTHEPRODUCT TURNTHEFEETANT...

Страница 25: ...hether to extract the smoke from the rear or the top of the product The product arrives set up with the outlet at the back if you wish to connect the outlet to the top proceed as follows Remove cap H...

Страница 26: ...24 A A B D C 6 PANEL REMOVAL COVERING KIT The covering of the stove is composed of lateral side 2 pieces right front side 1 piece left front side 1 piece central side 1 piece screws...

Страница 27: ...ide and at the top screw the self tapping screw g onto the magnet f panel B D place the supplied felt pad e onto the screw g to avoid vibrations and noise during operation of the stove In order to eas...

Страница 28: ...that wire x of the panel is aligned with wire y of the top of the structure Affix panels B and D with the three screws i l m Before applying the panels also on the inside towards the hearth place the...

Страница 29: ...central panel C ensuring that slot n enters the panel at joint o of the structure Verify the alignment between the three panels B C D If the alignment is satisfactory proceed with fixing the side pan...

Страница 30: ...L Adjustment of the central panel C Loosen the three screws p and lower or raise the stopper q where the central panel C is to be applied Once the correct alignment has been found definitively apply t...

Страница 31: ...erved Reproduction is prohibited Applying side panels Panel D and the left one B were previously affixed to the structure from the outside by way of screws l m n now you must complete the application...

Страница 32: ...l panel Both side front panels B and D having been fixed into place you may proceed with applying panel C Open the door of the stove insert the panel in its place as previously explained and fix it to...

Страница 33: ...duction is prohibited Applying side panels A In order to install the side panels A proceed as follows Lift the top W or Z Insert panel A in track t The side panels close by means of a magnet previousl...

Страница 34: ...l the top T can come out of the slot at the top Attention Thisoperationmustbecarriedoutwithoutthecoveringpanelsofthestoveandwiththetwosidepanelsopen OPENING CLOSING THE DOOR OF THE FIREBOX ATTENTION T...

Страница 35: ...e electronic board you must open the side panel remove the two screws p and lower the window If it is necessary to connect external cables to the appliance feed the cables through the hole F on the ba...

Страница 36: ...e stove and pour in the pellets Automatic Loading with remote tank of 100 200 or 400 kg optional see accessories At the back of the stove remove the knockout hole U and attach the duct V for the addit...

Страница 37: ...vent of failed ignitions What to do in the event of alarms in particular those generated when the appliance runs out of fuel How to maintain the appliance correctly and the importance of carrying out...

Страница 38: ...pply 3 4 M E SYSTEM EMPTYING 1 2 F A2 HEATINGWATER RETURN 3 4 M IMPORTANT CLEANTHEENTIRESYSTEMBEFORECONNECTINGTHESTOVE INORDERTOREMOVEALLRESIDUEANDDEPOSITS Alwaysinstallshuttersinthesystemleadingtothe...

Страница 39: ...orised centres product is recommended this provides long term protection of heating systems against corrosion and calcium build up It prevents the corrosion of the metal parts of the appliance i e the...

Страница 40: ...escale especiallyinthe domesticwaterheatexchanger 25 French Installationofawatersoftener ifwaterhardnessexceeds25 French Fillingthesystemwithtreatedwater demineralised Possiblyprovidingananti condensa...

Страница 41: ...ectrical wall socket The main switch must only be activated to switch the stove on otherwise it is advisable to keep it switched off Itisrecommendedtodisconnectthepowercablewhenthestoveisnotused STOVE...

Страница 42: ...m configuration by the room temperature probe located at the back of the appliance see img by the external thermostat by the temperature of the water in the boiler or by the NTC probes ELECTRICAL CONN...

Страница 43: ......

Страница 44: ...REV 0 8901506100 12 01 2015 Via La Croce n 8 33074Vigonovo di Fontanafredda PN ITALY Telephone 39 0434 599599 r a Fax 39 0434 599598 Internet www mcz it e mail info red mcz it...

Отзывы: