2 - INSTALLATION INSTRUCTIONS
FOREWORD
The installation position must be chosen according to the room, to the smoke extraction system, to the chimney flue. Check with local
authorities whether there are any restrictive regulations in force regarding the combustion air inlet, the smoke outlet system, the
flue or the chimney cap. The manufacturer declines all responsibility in the event of installations that do not comply with the laws in
force, incorrect room air exchange, electrical connection non-compliant with the standards and inappropriate use of the appliance. The
installation must be carried out by a qualified technician, who must issue a declaration of conformity of the system to the purchaser and
will assume full responsibility for final installation and consequent good operation of the product.
In particular one must ensure that:
• there is a suitable combustion air inlet and smoke outlet in compliance with the type of product installed
• other stoves or devices installed do not cause depression in the room where the product is installed (for sealed appliances only, a
maximum of 15 Pa of depression in the room is allowed)
• when the product is switched on there is no reflux of smoke in the room
• fumes extraction takes place in total safety (sizing, smoke seal, distances from flammable materials..).
We especially recommend to check the data tags of the flue for the safety distances that must be observed in presence
of combustible materials and the type of insulating material to be used. These indications must be followed strictly to
prevent serious harm to people and the integrity of the home.
The installation of the appliance must ensure easy access to
clean the appliance itself, the smoke outlet pipes and the flue.
It is forbidden to install the stove in rooms with a fire hazard.
Installation in studio flats, bedrooms and bathrooms is only allowed with sealed or closed appliances equipped with
suitable combustion air ducting directly outside. Always maintain adequate distance and protection in order to prevent
the product from coming into contact with water.
In the event there are several appliances installed, the external air inlet must be sized accordingly.
MINIMUM DISTANCES
It is recommended to install the stove detached from any walls and/or furniture, with a minimum clearance to allow effective aeration of
the appliance and a good distribution of heat in the room.Observe distances from flammable or heat-sensitive objects (sofas, furniture,
wood panelling, etc..) as specified below. The front distance from flammable materials must be at least as set out in the product’s technical
data table.
If particularly delicate objects are present, such as furniture, curtains or sofas, increase the stove clearance accordingly.
If the floor is made of wood, it is recommended to fit a floor protection sheet in compliance with the Standards in
force in the country of installation.
FLUX HYDRO
Distance from flammable material (see p.18)
back = 1 cm
side = 2 cm (MIN. 30 cm to open the door)
If the floor is made of combustible material, it is recommended to use protection made of non-combustible material (steel, glass...) that
also protects the front from falling combusted material during cleaning operations.
The appliance must be installed on a floor with adequate load capacity.
If the existing construction does not meet this requirement, one must take appropriate measures (for example a load distribution plate).