12
A
B
C
D
E
A
B
C
D
15°
E
F
A
B
C
D
E
30°
F
2 - INSTALLATION INSTRUCTIONS
TECHNICAL CHARACTERISTICS
Have the efficiency of the flue checked by an authorised technician.
The flue must be sealed against flue gasses, in a vertical direction without narrowing, be made with materials impermeable to smoke,
condensation, thermally insulated and suitable to resist normal mechanical stress over time (we recommend fireplaces made of A/316
or refractory material with insulated round section double chamber). Be suitably insulated externally to avoid condensation and reduce
smoke cooling. It should be separated from combustible or flammable materials with an air gap or insulating materials: check the distance
specified by the manufacturer of the fireplace according to EN1443. The chimney opening must be in the same room as the appliance,
or at most in the adjoining room, and have a soot and condensation collection chamber beneath the opening, and be accessible via a
watertight metal hatch.
FLAT ROOF
ROOF AT 15°
ROOF AT 30°
A = 0.50 metres
B = DISTANCE > 2 metres
C = DISTANCE < 2 metres
D = O.50 metres
E = TECHNICAL VOLUME
A = MIN. 1.00 metres
B = DISTANCE > 1.85 metres
C = DISTANCE < 1.85 metres
D = 0.50 metres above highest
point
E = 0.50 metres
F = REFLUX ZONE
A = MIN. 1.30 metres
B = DISTANCE > 1.50 metres
C = DISTANCE < 1.50 metres
D = 0.50 metres ABOVE
HIGHEST POINT
E = 0.80 metres
F = REFLUX ZONE
FIGURE 2
FIGURE 3
FIGURE 4