EN
FUNCTIONS
Screen where you may execute the advanced functions of the stove. Browse using the keys
and select by pressing OK. Press
HOME
to go back to the main menu
The menu consists of the following:
AUTO MODE:
To set the MANUAL or AUTOMATIC operating mode
ECO STOP:
The ECO STOP menu allows you to set and/or modify an activation delay (min) and a
re-ignition hysteresis (C°). ECO is an automatic mode with the only difference that if the
set temperature is reached and remains so for the time (in minutes) that was selected
from the delayed activation MENU (value ranging between 5 and 30 minutes), the
product switches off and remains on stand-by until the room temperature drops below
the desired temperature (hysteresis frequency ranges between 2 and 5 minutes). The
product is then switched on again.
If the room is not sufficiently insulated, flame modulation does not allow the set tem-
perature to stay satisfied for the time set and the product will not switch off.
NOTE: It is recommended to use the ECO mode only in well-insulated rooms in order to
prevent start-up and shutdown from occurring within short periods of time.
SLEEP MODE:
The SLEEP mode allows to quickly set the time at which the product must switch off. This
function is only available in MAN and AUTO mode. To disable SLEEP mode, simply enter
regulation and bring the countdown to zero.
CHRONOTHERMOSTAT:
Select this operating mode to switch the product on and off automatically. The programs
are freely programmable for each 1/2 hour of the day on three different temperature
indicators (T1-T2-T3) and in different ways for each day of the week.
THE CHRONOTHERMOSTAT
In the chronothermostat menu you may set:
•
CHRONO ON/OFF
•
T1 / T2 / T3: to set the on and off and regulation temperatures
•
DAYS: To set the days of the week on which the stove must switch on/off and at which temperatures (T1/T2/T3)
5-OPERATION