Mounting Installation Plate
Ensure that the wall is strong enough to withstand the weight
of the unit. Otherwise, it is necessary to reinforce the wall
with plates, beams or pillars.
Use the level gauge for horizontal mounting, and fix it with
5 suitable screws for (5)WM09/10/15J/JR and 7 suitable
screws for WM20/25J/JR.
In case the rear piping draws out, drill a hole 65mm in
diameter with a cone drill, slightly lower on the outside
wall (see figure).
Through
the wall
hole
Ø 65mm
Recommended mounting plate
retention spots (7 spots in all)
190
173
61
310
61
Drain hose
position
Gas pipe end
Liquid pipe end
48
45
580
1065
219
40
40
91
45
Inside
Caulking
Outside
Wall embedded pipe
(Field supply)
Wall hole cover
(Field supply)
Wall embedded pipe
(Field supply)
Ø 65
Mounting plate
Water Drainage Piping
The indoor drain pipe must be in a downward gradient for
smooth drainage. Avoid situations that are likely to cause
water to leak.
End
dipped
into
water
Water
leaking
Water
leaking
Water
leaking
Wrong
Wrong
Wrong
Drain
Water Drainage
Mounting
plate
Clip
Mark (rear side)
Bottom frame
Front grille
How To Attach The Indoor Unit
Hook the claws of the bottom frame to the mounting plate.
How To Remove The Indoor Unit
Push up the marked area (at the lower part of the front grille)
to release the claws.
Mount The Unit Onto The Installation Plate
Hook the indoor unit onto the upper portion of the
installation plate (Engage the two hooks at the rear top of
the indoor unit with the upper edge of the installation plate).
Ensure that the hooks are properly seated on the
installation plate by moving it to the left and right.
Mounting plate
Interconnecting
wires
Hang indoor unit’s hook here.
Wire guide
When stripping the
ends of interconnecting
wires in advance, bind
right ends of wires with
insulating tape.
Mounting plate
fixing screw
Through
the wall
hole
Ø 65mm
Drain
hose
position
Recommended mounting plate
retention spots (5 spots in all)
Use tape measure as shown.
Position the end of a tape measure
at
Gas pipe end
Liquid pipe end
Recommended Mounting Plate Retention Spots
And Dimensions
166
184
181.7
55.5
54.5
153.8
263
51.9
800
45.9
42.2
288
42.2
45.9
Hole with cone drill
Water
Retention
All dimensions are in mm
Correct
Mounting plate
Mounting plate
fixing screw
WM20/25J/JR
(5)WM09/10/15J/JR
WM20/25J/JR
(5)WM09/10/15J/JR
All dimensions are in mm
1 IM-WMJ-1207(2)_EN
11/20/09, 4:32 PM
8
Содержание R08019031289A
Страница 19: ...MEMO 1 IM WMJ 1207 2 _EN 11 20 09 4 32 PM 18...
Страница 37: ...LE M MO 2 IM WMJ 1207 2 _FR 11 20 09 4 32 PM 18...
Страница 55: ...MITTEILUNG 3 IM WMJ 1207 2 _DE 11 20 09 4 33 PM 18...
Страница 73: ...PROMEMORIA 4 IM WMJ 1207 2 _IT 11 20 09 4 33 PM 18...
Страница 91: ...EL MEMOR NDUM 5 IM WMJ 1207 2 _ES 11 20 09 4 34 PM 18...
Страница 92: ...6 1 K 5 WMJ A A B C H I B F E J G G L D B K M A 5 WM09 10 15J JR 65 F 5 6 IM WMJ 1207 2 _RU 11 20 09 4 34 PM 1...
Страница 95: ...6 4 CTOPO HO OFF H MAH E 1 1 PE PE EH E 6 IM WMJ 1207 2 _RU 11 20 09 4 34 PM 4...
Страница 96: ...6 5 R410A 1 1975 1 1 2 1 2 1 2 2 3 4 C 5 6 2 6 IM WMJ 1207 2 _RU 11 20 09 4 35 PM 5...
Страница 98: ...6 7 50 A 1 2 4 5 6 3 50 30 y ox c 6 IM WMJ 1207 2 _RU 11 20 09 4 35 PM 7...
Страница 106: ...6 15 1 2 2 3 4 4 5 FRONT K a CTOPO HO 1 3 2 4 K a 6 IM WMJ 1207 2 _RU 11 20 09 4 35 PM 15...
Страница 107: ...6 16 1 2 2 3 c CTOPO HO 40 C 1 40 104 F 2 3 1 40 104 F 2 6 IM WMJ 1207 2 _RU 11 20 09 4 35 PM 16...
Страница 108: ...6 17 2 30 C 86 F 3 4 1 3 2 3 4 5 6 7 6 IM WMJ 1207 2 _RU 11 20 09 4 35 PM 17...
Страница 109: ...M TKA 6 IM WMJ 1207 2 _RU 11 20 09 4 35 PM 18...
Страница 127: ...NOT NOT NOT NOT NOT 7 IM WMJ 1207 2 _TR 11 20 09 4 36 PM 18...
Страница 130: ...d c 0 IM WMJ 1207 2 _AR 11 20 09 4 43 PM 18...