Introduction
The air-cooled mini chillers form part of a complete integrated water hydronic system with the
chiller water fan coil units. The range of capacity from 30,000 Btu/hr to 150,000 Btu/hr (8.79 –
43.96 KW) makes them suitable for various applications:
-
Office
Rooms
-
Private
Houses
-
Business
Rooms
-
Club, Pubs, Coffee Houses
-
Hotels
-
Restaurants
-
Process
Cooling
The advantages of using these chillers are:
1. Due to its compact design, the mini-chillers require a smaller space for installation.
The design also allows for flexibility in design to meet various types of application
requirements.
2. The amount of refrigerant used is small compared with other split and multi-split direct
expansion systems, i.e. they are more environmental friendly.
3. There is no necessity to use cooling towers.
4. No refrigerant is used in the occupied space.
5. The usage of water as the cooling medium allows for excellent load variability with minimal
system complexity as against equivalent VRV systems.
6. Ability to have long piping distances.
A water hydronic system can be classified as a close or open system.
Definition
: A close water system is one with no more than one point of interface with a
compressible gas or surface.
[ASHRAE handbook: 1996
System &
Equip.]
The basic design of the mini-chiller is for a close system. However, a modification for an open
system is possible.
The close hydronic system will consist of the following fundamental components:
a. Source
b. Load
c. Expansion Tank
d. Pump
e. Distribution System
Introduction Page
1
Содержание AC 40A
Страница 1: ...AM MAC ...
Страница 153: ...Appendix 1 ...
Страница 154: ...Appendix 2 Appendix 2 ...
Страница 157: ...GRAPH OF PRESSURE DROP VS FLOW FOR VARIOUS C V RATINGS Appendix 5 1 ...
Страница 158: ......
Страница 159: ...Water Capacity Graph Appendix 5 2 ...
Страница 160: ...CHART 3 FRICTION LOSS FOR CLOSED PIPING SYSTEMS Appendix 6 1 ...
Страница 161: ...CHART 4 FRICTION LOSS FOR OPEN PIPING SYSTEMS Appendix 6 2 ...
Страница 162: ...CHART 5 FRICTION LOSS FOR CLOSED AND OPEN PIPING SYSTEMS Appendix 6 3 ...
Страница 168: ...Appendix 8 Appendix 8 ...
Страница 169: ...Appendix 8 1 ...
Страница 170: ...Appendix 8 2 ...
Страница 171: ...Appendix 8 3 ...
Страница 172: ...Appendix 8 4 ...
Страница 173: ...Appendix 8 5 Appendix 8 5 ...
Страница 174: ...Appendix 8 6 Appendix 8 6 ...
Страница 175: ...Appendix 8 7 Appendix 8 7 ...
Страница 176: ...Appendix 9 ...
Страница 178: ...Appendix 11 1 Appendix 11 1 ...
Страница 179: ...Appendix 11 2 Appendix 11 2 ...
Страница 180: ...Appendix 13 ...
Страница 181: ...Appendix 13 1 ...
Страница 182: ...Appendix 14 Appendix 14 ...
Страница 183: ...Appendix 15 1 Appendix 15 1 ...
Страница 186: ...Appendix 17 Appendix 17 ...
Страница 187: ...Appendix 18 ...
Страница 188: ...CE20DW CE25DW Note PRESSURE DROP CORRECTION FACTOR 1 2947 0 0021 EWTºF Appendix 19 ...
Страница 189: ... 2003 McQuay International 603 55194922 www mcquayup com ISO 9002 REGISTERED ...