Programmable Thermostat 

MH6-HP

 

 

 

                                                                   

Introduction                                                       

 

MH6-HP  programmable  thermostat  is  a  Z-Wave  Plus  enabled  device  for  indoor  temperature 

control.  It  is  mainly  applied  to  heat  pump  system  for  heating/cooling,  with  3  modes  easily 

switchable: Schedule, Hold and Holiday. The device is of high reliability and practicability, and it 

can  support  up  to  3H/2C  system.  This  product  can  be  included  and  operated  in  any  Z-Wave 

network  with  other  Z-Wave  certified  devices  from  any  other  manufacturers.  All  non-battery 

operated nodes within the network will act as repeaters regardless of vendor to increase reliability 

of the network. 

 

Features

 

 

Elegant design with 4.3” LCD display 

 

Individual programming Schedules:   

                  7 days*4 time periods   

 

Tempered glass panel with   

                  Capacitive touch buttons 

 

 

NTC thermistor 

 

Built-in Z-Wave module   

 

                                                            Specification                                                         

Power supply

  AC24V, 50/60Hz 

Power dissipation

2W 

Dimension: 136*94*26mm   

Output: <1A (Resistant load) 

Temperature range: 41ºF -99ºF (5

  -37

)   

Display accuracy: ±0.5 ºC 

Wiring: Terminals 

Installation dimension: 60mm / 82mm (hole pitch)                                                     

 

 

                                                         

                                                               

  Safety Information   

                                                   

To protect yourself and others from danger and to protect the device from damage, please read the 

safety information before using it. 

Important!   

 

A qualified electrician with the understanding of wiring diagrams and knowledge of electrical 

safety should complete installation following the instructions. 

 

Before installation, please confirm the real voltage complying with the device’s specification. 

Cut off any power supply to secure the safety of people and device.   

 

During installation, protect the device from any physical damage by dropping or bumping. If 

happens, please contact the supplier for maintenance. 

Содержание MH6-HP

Страница 1: ...d glass panel with Capacitive touch buttons NTC thermistor Built in Z Wave module Specification Power supply AC24V 50 60Hz Power dissipation 2W Dimension 136 94 26mm Output 1A Resistant load Temperatu...

Страница 2: ...id damage Avoid overexertion during operation to protect device from mechanical damage Read all instructions and documentation and save for future reference Installation Wiring CAUTION Cut off power s...

Страница 3: ...Cool output Compressor output heat pump G Fan output C 24VAC common Connect only when AC power Y2 Cool output 2 2nd stage compressor output heat pump W2 AUX Heat output 2 Auxiliary heat output heat pu...

Страница 4: ...ack to the temperature setting interface displays and temperature value flashing then press or to modify the value press F or wait for the delay time end return back to normal display Local time can n...

Страница 5: ...ps and Heat on disappears from screen Note Aux heat stops and AUX disappears when temp difference is less than 2 2nd heat stops when temp difference is less than 1 Cool Changeover valve keep open Room...

Страница 6: ...tting Press to save and enter schedule setting for the following day Under the time setting mode when the time is set to the current schedule will be disabled and it will follow the previous time sett...

Страница 7: ...ly back to normal work until the sensor circuit is normal again Z Wave operation Adding Removing of Z Wave network In normal display press hold to enter interface for adding or removing of Z Wave netw...

Страница 8: ...es Restoring Factory Settings 1 Remove the device out from Z Wave network can restore factory setting 2 Configure the parameter 10 in secret menu can restore the factory setting also Please use this p...

Страница 9: ...ype 1 1H 1C Differential 0 5 1 1 5 2 1 0 2 Temperature calibration 10 10 0 0 3 Temperature setting upper limit 0 37 37 0 Upper limit value lower limit value 4 Temperature setting lower limit 0 37 5 0...