background image

                                                                                                                                User Manual

 

 

     

 

2

 

 

Keep  the  device  away  from  acid-base  and  other  corrosive  solids,  liquids,  gases,  to  avoid 

damage.   

 

Avoid overexertion during operation, to protect device from mechanical damage. 

 

Read all instructions and documentation and save for future reference. 

 

                                                    Installation & Wiring                                                   

CAUTION: Cut off power supply at circuit breaker or fuse before installation to avoid fire, shock 

or death!

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Wiring diagram 
 
 
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 

Содержание MH6-HP

Страница 1: ...d glass panel with Capacitive touch buttons NTC thermistor Built in Z Wave module Specification Power supply AC24V 50 60Hz Power dissipation 2W Dimension 136 94 26mm Output 1A Resistant load Temperatu...

Страница 2: ...id damage Avoid overexertion during operation to protect device from mechanical damage Read all instructions and documentation and save for future reference Installation Wiring CAUTION Cut off power s...

Страница 3: ...Cool output Compressor output heat pump G Fan output C 24VAC common Connect only when AC power Y2 Cool output 2 2nd stage compressor output heat pump W2 AUX Heat output 2 Auxiliary heat output heat pu...

Страница 4: ...ack to the temperature setting interface displays and temperature value flashing then press or to modify the value press F or wait for the delay time end return back to normal display Local time can n...

Страница 5: ...ps and Heat on disappears from screen Note Aux heat stops and AUX disappears when temp difference is less than 2 2nd heat stops when temp difference is less than 1 Cool Changeover valve keep open Room...

Страница 6: ...tting Press to save and enter schedule setting for the following day Under the time setting mode when the time is set to the current schedule will be disabled and it will follow the previous time sett...

Страница 7: ...ly back to normal work until the sensor circuit is normal again Z Wave operation Adding Removing of Z Wave network In normal display press hold to enter interface for adding or removing of Z Wave netw...

Страница 8: ...es Restoring Factory Settings 1 Remove the device out from Z Wave network can restore factory setting 2 Configure the parameter 10 in secret menu can restore the factory setting also Please use this p...

Страница 9: ...ype 1 1H 1C Differential 0 5 1 1 5 2 1 0 2 Temperature calibration 10 10 0 0 3 Temperature setting upper limit 0 37 37 0 Upper limit value lower limit value 4 Temperature setting lower limit 0 37 5 0...