background image

                                                                                                                                User Manual

 

 

     

 

6

 

 

Schedule

 

 

        Any icon from 

  stands  for  one  time  period, and there are 4 periods  can be set in 

one day.   

 

Under the time setting mode, press 

 

to enter into time setting interface, the time parameter 

of cooling or heating mode can be set. Press 

  then 

switch among 

7 days 

 

5+2 days

 

 

a whole week:

 [ 

MON

TUE

WED

THU→FRI→SAT→SUN→

MON TUE WED THU FRI

SAT SUN

MON  TUE  WED  THU  FRI  SAT  SUN

 

]. 

When  setting  the  parameters,  press  F  to  exit  to  the 

modify interface, then get back to the temperature setting interface. 

       

 

1.  Press 

flashes

 

then  press 

 

or 

  to  change  the  time  (changes  in  15  minutes  at  a 

time); 

 

2.  After  completed  the  time  setting,  Press

  to  switch  to  the  temperature  setting,  setting 

temperature flash and press 

  or 

  to modify the setting temperature. 

 

3. After finished the above steps, press 

  to switch to 2

st

 period of Monday and repeat item 

1  and  2  steps,  then  complete  4  periods  of  Monday  setting.  Press 

  to  save  and  enter 

schedule setting for the following day.   

 

Under  the  time  setting  mode,  when  the  time  is  set  to  -  -

-  -,  the  current  schedule  will  be 

disabled, and it will follow the  previous time setting  until enter into the  next schedule. If 4 

period of a day is - - -

- --, then it will run the last schedule by default. 

The below table is the time parameter setting in different modes: 

(Factory Default)

 

 

 

 

 

 

 

 

 

Notes: Cooling and Auto mode use the same setting schedule.

 

 

 

Hold 

This  mode  comes  after  “

Schedule

”  by  pressing 

F

.  In  this  mode,  device  will  keep  a  constant 

temperature until next change. 

 

“Hold” 

&  “

 

display  and  temperature  value  flashing.  Press 

 

or 

 

can  change 

the value, and press 

F

 to save the setting; 

 

Press 

  can set system state;   

 

Press 

  can set fan mode.

 

 

 

Hold Until (Holiday) 

This  mode comes after  “

Hold

”  by pressing 

F

  again. In this  mode, device will  follow the setting 

temperature and lasting days when users are out for a holiday. And then back to follow 

Schedules

 

after the holiday. 

Periods 

Time 

Parameters 

Heating 

Cooling/ Auto 

06:00 

21.0℃ 

25.5℃ 

08:00 

16.5℃ 

29.5℃ 

18:00 

21.0℃ 

25.5℃ 

22:00 

16.5℃ 

28.0℃ 

Содержание MH6-HP

Страница 1: ...d glass panel with Capacitive touch buttons NTC thermistor Built in Z Wave module Specification Power supply AC24V 50 60Hz Power dissipation 2W Dimension 136 94 26mm Output 1A Resistant load Temperatu...

Страница 2: ...id damage Avoid overexertion during operation to protect device from mechanical damage Read all instructions and documentation and save for future reference Installation Wiring CAUTION Cut off power s...

Страница 3: ...Cool output Compressor output heat pump G Fan output C 24VAC common Connect only when AC power Y2 Cool output 2 2nd stage compressor output heat pump W2 AUX Heat output 2 Auxiliary heat output heat pu...

Страница 4: ...ack to the temperature setting interface displays and temperature value flashing then press or to modify the value press F or wait for the delay time end return back to normal display Local time can n...

Страница 5: ...ps and Heat on disappears from screen Note Aux heat stops and AUX disappears when temp difference is less than 2 2nd heat stops when temp difference is less than 1 Cool Changeover valve keep open Room...

Страница 6: ...tting Press to save and enter schedule setting for the following day Under the time setting mode when the time is set to the current schedule will be disabled and it will follow the previous time sett...

Страница 7: ...ly back to normal work until the sensor circuit is normal again Z Wave operation Adding Removing of Z Wave network In normal display press hold to enter interface for adding or removing of Z Wave netw...

Страница 8: ...es Restoring Factory Settings 1 Remove the device out from Z Wave network can restore factory setting 2 Configure the parameter 10 in secret menu can restore the factory setting also Please use this p...

Страница 9: ...ype 1 1H 1C Differential 0 5 1 1 5 2 1 0 2 Temperature calibration 10 10 0 0 3 Temperature setting upper limit 0 37 37 0 Upper limit value lower limit value 4 Temperature setting lower limit 0 37 5 0...

Отзывы: