Troubleshooting
EP800AD (Acrobat™ HPU)
Open/Close Switch Not
Functioning
Main Circuit Breaker
Trips
Check power to
solenoids per switch position. This can
be done with a volt meter at the plug that supplies the solenoids
power, and should read 24V when switch is in corresponding
Open/Close position.
No:
• Check open/close switch and wiring per
.
If the main breaker trips let the unit cool for 3 minutes and try to
reset. Does it trip after reset?
Yes:
• If the main breaker trips immediately upon resetting, visually inspect
wiring inside electrical box for damage or a shorting condition.
Check solenoid resistance, solenoid should read around 34 (+/- 5)
Ohms.
• If the resistance is less, this indicates a shorted fault. If the resistance is
more, this indicates an open fault and the solenoid should be replaced.
Refer to
section for more information
Inspect/Check all fuses.
• If all fuses check out properly this indicates a fault in either the EMI
filter, main breaker, or the wiring between the main breaker and fuses
Check solenoid retention nut for proper torque.
No:
• Loosen nut and re-torque to correct value of 4 - 5 ft-lbs (5.4 - 6.8
Nm).
Yes:
• Replace the cartridge valve.
Содержание Acrobat EP800AD
Страница 2: ......
Страница 13: ...Machine Specifications 2 3 Machine Specifications EP800AD Acrobat HPU This page was intentionally left blank...
Страница 40: ...Electrical 6 11 Electrical EP800AD Acrobat HPU This page was intentionally left blank...
Страница 64: ...Previous Revisions 8 7 Previous Revisions EP800AD Acrobat HPU Hydraulic Schematic Revision 1 and 2...
Страница 71: ...Notes 10 1 Notes EP800AD Acrobat HPU NOTES Notes...
Страница 72: ......