background image

xi

Contents

Appendix H

Manual Configuration of the Initial IP Settings

Manually Configure the Maintenance IP Port using the 
Command Line Interface  .............................................................. H-1
Update UltraNet ConfigManager with the Manual 
Configurations  ................................................................................ H-3

Appendix I

Using the Spantree Portfast Command for Cisco Routers

Issuing the Spantree Portfast Command  ...................................... I-1

Appendix J

Configuration Worksheets

Configuration Worksheets  .............................................................. J-1

IP Configuration Worksheet..................................................... J-2
ATM WAN Configuration Worrksheet ................................... J-4

Содержание ULTRANET EDGE 3000

Страница 1: ...UltraNet Edge Storage Router 3000 Release 3 2 User Guide P N 620 000248 030 REV A...

Страница 2: ...F MERCHANTIBILITY AND FITNESS FOR A PARTICULAR PURPOSE In no event shall McDATA Corporation be liable for a incidental indirect special or consequential damages or b any damages whatsoever resulting f...

Страница 3: ...onfigurations 2 6 FC SCSI Tape Pipelining 2 6 Valid Hardware Interface Configurations 2 7 Fibre Channel Card Dependencies 2 8 FC SCSI E_port Configurations 2 8 FC SCSI F_port Configurations 2 9 FC SCS...

Страница 4: ...apter 5 Configuring an E_Port Extension over an Ethernet WAN Configuring a 1x1 Ethernet Wide Area Network 5 1 Gathering the IP Addresses 5 2 Starting UltraNet ConfigManager 5 3 Adding Nodes for an Eth...

Страница 5: ...ATM Circuit 7 11 Creating a Data Path 7 24 Delivering the Configured Network 7 30 Setting the Delivery Properties 7 30 Delivery Wizard 7 31 Deliver Network 7 33 Viewing Logs 7 34 Chapter 8 Configuring...

Страница 6: ...thernet WAN Configuration 9 11 Setting the Initial Configuration 9 13 Setting the License Information 9 16 Adding an IP Circuit 9 18 Creating a Data Path for Fibre Channel Device Extension Interfaces...

Страница 7: ...r Software 11 15 Chapter 12 Hardware Maintenance Front and Rear View of UltraNet Edge 3000 Chassis 12 2 Replacing the UltraNet Edge 3000 Chassis 12 2 Fan Assembly Removal Procedure 12 3 Fan Assembly I...

Страница 8: ...12 28 Replacing the Fibre Channel Short Wave Transceiver 12 29 Removing the Fibre Channel Short Wave SFP Transceiver 12 29 Installing the Fibre Channel Short Wave SFP Transceiver 12 30 Replacing the F...

Страница 9: ...Appendix A Site Preparation Site Requirements A 1 UltraNet Edge 3000 Chassis Dimensions A 1 Clearance Requirements A 2 Environmental Specifications A 3 Power Requirements A 4 Appendix B Installation a...

Страница 10: ...ly D 2 FC Switch Tab D 3 Time Synchronization Protocol D 6 Configure the Time Synchronization Protocol D 6 Transport CRC Checking D 8 E_Port Disk Streaming Settings D 9 Enable Disable E_Port Disk Stre...

Страница 11: ...and Line Interface H 1 Update UltraNet ConfigManager with the Manual Configurations H 3 Appendix I Using the Spantree Portfast Command for Cisco Routers Issuing the Spantree Portfast Command I 1 Appen...

Страница 12: ...UltraNet Edge Storage Router 3000 User Guide xii Contents...

Страница 13: ...CON ISL with Ethernet WAN using two UltraNet Edge 3000s 8 2 UltraNet ConfigManager Main Window 8 4 Uni directional FC SCSI Tape Pipelining No Zoning 9 2 Bi directional FC SCSI Tape Pipelining with Zon...

Страница 14: ...xiv UltraNet Edge Storage Router 3000 User Guide Figures...

Страница 15: ...Disk Streaming 3 12 Fibre Channel Switch Zoning Definitions for Figure 8 2 9 3 Fibre Channel Switch Zoning Definitions for Figure 8 3 9 5 Fictitious WWNs for Devices shown in Figure 8 3 9 6 Edge 10 St...

Страница 16: ...C 3 Pinout Initials C 3 Fibre Channel Cable and Connector Specifications C 4 Ethernet 10 100 Cable and Connector Specifications C 6 Gigabit Ethernet Cable and Connector Specifications C 6 OC 3 ATM Ca...

Страница 17: ...its and security information Chapter 2 Hardware Configurations provides the valid hardware configurations possible with the new customizable UltraNet Edge 3000 features Chapter 3 Network Design Criter...

Страница 18: ...Configuring Tape Device Extension over an Ethernet WAN provides the procedures for configuring Tape Pipelining Device Extension on your UltraNet Edge 3000 using McDATA s UltraNet ConfigManager config...

Страница 19: ...ings Appendix E Static Routes describes how to display verify add and modify static routes Appendix F Configure SNMP provides an overview for configuring SNMP on the UltraNet Edge 3000 Appendix G Rese...

Страница 20: ...left press and hold down the CTRL key and press C Bold Courier text Bold Courier text is used for commands and for system input that you type exactly as shown value angle brackets Angle brackets in a...

Страница 21: ...Best in Class Solution Center provides a single point of contact for customers seeking help with McDATA software products The Solution Center will research explore and resolve inquiries or service re...

Страница 22: ...information on our complete family of enterprise to edge SAN solutions Fax 720 558 4193 Trademarks The following terms indicated by a registered trademark symbol or trademark symbol on first use in t...

Страница 23: ...n endorsement or through published literature invalidates the service contract and voids the warranty agreement with McDATA Canadian EMC Statements The statements below indicate product compliance wit...

Страница 24: ...including electrical business equipment The C UL US mark on a product indicates compliance with American National Standards Institute ANSI and Standards Council of Canada SCC safety requirements as t...

Страница 25: ...untries relating to EMC emissions and immunity Products conform with all protection requirements of EU directive 73 23 EEC Low Voltage Directive in accordance with the laws of the member countries rel...

Страница 26: ...regulatory requirements for EMC for information technology equipment as set forth by the Australian Communications Authority ACA and the Radio Spectrum Management Group RSM of New Zealand The China Co...

Страница 27: ...d by Underwriters Laboratories International Demko A S and accredited by the Central Office of Safety of the German L nder Zentralstelle der L nder f r Sicherheitstechnik or ZLS The Korean Ministry of...

Страница 28: ...egulatory requirements for safety and EMC for information technology equipment as authorized and accredited by the State Committee for Standardization Metrology and Certification The South African Bur...

Страница 29: ...anslated statements in the McDATA Product Safety Notices 620 000247 Use the supplied power cords Ensure the facility power receptacle is the correct type supplies the required voltage and is properly...

Страница 30: ...on of the equipment is not compromised When mounting equipment in a rack avoid uneven loading to prevent a tipping hazard Be sure the electrical supply circuit is adequate based on the quipment namepl...

Страница 31: ...xxi Preface General Precautions When installing or servicing the product follow these practices Always use correct tools Always use correct replacement parts Keep all paperwork up to date complete and...

Страница 32: ...wear an ESD wrist strap and grounding cable connected to the product chassis If the product is not connected to facility power not grounded wear an ESD wrist strap and grounding cable connected to an...

Страница 33: ...t provide high speed connectivity over local area networks LANs metropolitan area networks MANs and wide area networks WANs between servers peripheral devices remote storage devices and workstations F...

Страница 34: ...d procedures that allow a computer site to be put back in operation after a disaster has occurred The concept of moving back ups off site constitutes the minimum basic precaution for disaster recovery...

Страница 35: ...end CRC checking for guaranteed recovery and complete data integrity IP Load Balancing provides data striping across multiple virtual links for scalability and maximum application performance Fail Ov...

Страница 36: ...in the same chassis Auto negotiation Fibre Channel originator and responder modes Full duplex send and receive buffers Class 2 Class 3 and Class F connection FCSW internal Fibre Channel switch applica...

Страница 37: ...ckbone routers Memory interface for reading Transceiver MSA information International Class 1 laser safety certified for voltage 4 0 volts Auto negotiation 64 bit SNMP counters 802 1Q VLAN support 4 L...

Страница 38: ...over multi mode fiber Optional long wave 1550nm Small Form Factor Pluggable SFP optical transceiver for distances up to 40 kilometers over single mode fiber 2 LEDS one for Carrier Detect and 1 for tr...

Страница 39: ...et Edge 3000 box 2 When prompted for the password enter the default password password 3 To change the default enter the system passwd command at the prompt tm 0x10 system passwd 4 Enter the old passwo...

Страница 40: ...1 1 8 McDATA UltraNet Edge 3000 User Guide UltraNet Edge 3000 Security...

Страница 41: ...UltraNet Edge 3000 chassis and the software license Each additional component or feature is ordered separately the following tables describe the optional features and requirements for customizing your...

Страница 42: ...ity card with a maximum of two Fibre Channel connectivity cards require an SFP Requirements are as follows FCBB Fibre Channel card requires one SFP per card either short wave multi mode or long wave s...

Страница 43: ...hassis must have at least one WAN connectivity card with a maximum of two WAN connectivity cards may require SFP options the requirements are as follows 10 100 Ethernet does not require an SFP Gig E r...

Страница 44: ...rd Configuration requirements WAN connectivity SFP options required for certain WAN connectivity cards as follows 10 100 Ethernet does not require an SFP Gig E requires one SFP per card either short w...

Страница 45: ...2 2x1 and 3x1 configurations but they are not supported as standard implementations The 1x1 configuration consists of One Fibre Channel interface extended over one 10 100 Ethernet or one Gigabit Ether...

Страница 46: ...xtended over one OC 3 ATM WAN aces extended over one OC 3 ATM WAN The 2x2 configuration consists of Two Fibre Channel interfaces extended over two OC 3 ATM WANs FC SCSI Tape Pipelining The UltraNet Ed...

Страница 47: ...onfiguration I O 4 I O 3 I O 2 I O 1 Featurized Configurations 1x1 10 100 Ethernet Gigabit Ethernet OC 3 ATM Fibre Channel FCBB 2x2 10 100 Ethernet Gigabit Ethernet OC 3 ATM 10 100 Ethernet Gigabit Et...

Страница 48: ...tions An E_port is an expansion port used to link multiple Fibre Channel switches together into a single fabric The UltraNet Edge 3000 offers the standard E_port configuration and E_port Disk Streamin...

Страница 49: ...ort Disk Streaming which moves data more efficiently in high latency networks than our standard F_port solution F_port Disk Streaming functions as a subset of our Fibre Channel Device Extension techno...

Страница 50: ...es governing data flows over ISLs must be defined so that CHPID I Os flow bi directionally over the same ISL When configuring a FICON path to be a FICON ISL you must enable the E port Cascaded ISL FIC...

Страница 51: ...n Batching is only allowed if the destination id is not the same as the source id and all the frames in the batch are for the same destination id At this time two ports are supported by the FCSW See C...

Страница 52: ...net or OC 3 ATM See Table 2 6 for the possible configurations The four fans two power plugs and two power switches are located at the back of the UltraNet Edge 3000 unit see Figure 2 3 Figure 2 3 Rear...

Страница 53: ...1 I O 1 This slot is available for a Fibre Channel card or Gigabit Ethernet card 3x1 configurations 2 I O 2 This slot is available for a Fibre Channel card 3 I O 0 Ethernet Maintenance Interface One 1...

Страница 54: ...at the operating system is executing instructions Yellow 10 BMEM activity The BMEM LED indicates buffer memory activity Green 11 Reset button Press in to reset the entire system 12 Abort button Press...

Страница 55: ...o End CRC as well as MTU Batching Network Design Specific information regarding each component of your network is required for successful design and configuration The following sections for the networ...

Страница 56: ...ation Default Gateway IP host address on the Ethernet maintenance interface and Ethernet WAN interface Static route information IP host address of the natively attached routers or switches SNMP inform...

Страница 57: ...fined for the Ethernet maintenance interface and the other static routes are used for the WAN The end to end network must have less than 1 packet loss The UltraNet Edge 3000 has SNMP support SNMP acce...

Страница 58: ...ectly connected that do not support Auto Negotiate NOTE The UltraNet Edge 3000 Gigabit Ethernet interface must remain at the default setting of Auto Negotiate when connected to a Cisco router Ethernet...

Страница 59: ...onfigManager When you perform the initial TCP IP configuration using the UltraNet ConfigManager the PC which has UltraNet ConfigManager installed on it must be on the same LAN and subnet as the Ethern...

Страница 60: ...d contact information Community names Trap Destinations Required Network Design Information for an ATM Network The following is a list of pertinent information for each network component that you will...

Страница 61: ...witch FCSW application and when configured for F_port an external Fibre Channel switch is not necessary unless more than two Fibre Channel ports are needed McDATA supports F_port using the McDATA inte...

Страница 62: ...e Fibre channel interface is dedicated to a single WAN interface If this option is selected for a Fibre Channel Switch interface and is a 2x2 configuration both Fibre Channel Switch ports are dedicate...

Страница 63: ...e sequencing of data frames on the virtual circuit when one of the links is running at significantly lower quality the link running at a higher quality will perform similar to the lower quality link W...

Страница 64: ...ange Link Parameter ELP response in order to establish a successful E_port Inter Switch Link ISL The UltraNet Edge 3000 now has an option in the Fibre Channel configuration file which allows either th...

Страница 65: ...ibre Channel switches with multiple ISLs Configure static ISL routes between end points where possible Required Minimum Hardware for E_Port Disk Streaming For miminum hardware levels for E_port Disk S...

Страница 66: ...specified format Upon a transmit during the frame gathering transfer of buffer memory is when a frame level CRC is performed If the value contained in the frame is correct it is transmitted If not the...

Страница 67: ...etermine if each attached Fibre Channel PCI card has hardware installed with CRC support The ON OFF status of End to End CRC is displayed in the fcxl2 dump crc_stats user interface command When an FCP...

Страница 68: ...for both Frame Level and End to End CRC are provided in the UltraNet Edge Storage Router 3000 Series Release Notes part number 30200581 Fibre Channel MTU Batching MTU Batching is available on the Ult...

Страница 69: ...configuring a 1x2 or 2x1 configuration type network If you are configuring a 1x1 or 2x2 type solution the UltraNet Edge 3000 Series Node menu contains pre designed selections for Ethernet and ATM 1x1...

Страница 70: ...eView Area and the Network Map The Nodes tab displays three drop down menus 2 Click the drop down menu for the UltraNet Edge 3000 Series 3 Select the Edge3000 Custom Chassis Configure Node10 4 Place y...

Страница 71: ...3000 Chassis 4 3 Building the Custom Chassis The Custom Chassis Wizard Introduction screen appears 6 Click Next The Custom Chassis Wizard Node10 Choose Customization Method screen appears 7 Select Bui...

Страница 72: ...Node10 Choose WAN Interfaces screen appears 8 Select the type of WAN you are configuring and the quantity in the drop down menu If you are configuring a 1x2 or 2x2 implementation enter a 2 in the quan...

Страница 73: ..._port configurations If you are configuring a 2x1 or 2x2 implementation enter a 2 in the quantity field 11 Click Next The Custom Chassis Wizard Node10 Choose Applications screen appears 12 Select the...

Страница 74: ...p 15 Continue by configuring Node 20 Configure Node 20 To configure node 20 place your cursor over the Network Map Area It will turn to crosshairs Click to activate the Custom Chassis Wizard again The...

Страница 75: ...figuring an implementation using E_port extension over an Ethernet WAN use Chapter 5 Configuring an E_Port Extension over an Ethernet WAN as an example If you are configuring an implementation using F...

Страница 76: ...4 4 8 McDATA UltraNet Edge 3000 User Guide Building the Custom Chassis...

Страница 77: ...sion with an additional single attribute in the UltraNet ConfigManager application Prior to configuring the UltraNet Edge 3000 you should be familiar with Fibre Channel 10 100 Ethernet and Gigabit net...

Страница 78: ...gured with two UltraNet Edge 3000s as a 2x2 implementation Figure 5 1 Sample E_port Ethernet WAN with two UltraNet Edge 3000s Using the Configuration IP Address Worksheet in Appendix J gather the IP a...

Страница 79: ...n from either the icon on your desktop or the Start menu You have the option to use the Online Tutorial when you first open the UltraNet ConfigManager software You can use either the Online Tutorial o...

Страница 80: ...odes tab located on the toolbar between the TreeView Area and the Network Map Area see Figure 5 2 on page 3 The Nodes tab displays three drop down menus containing the node types for each available Ul...

Страница 81: ...e drop down list select the interface type you want as the Fibre Channel I F default This sets the default that UltraNet ConfigManager will use in each configuration When configuring an E_port extensi...

Страница 82: ...red an UltraNet Edge 3000 custom chassis in Chapter 4 continue the configuration process with the Setting the Initial Configuration procedure NOTE When you are performing this part of the configuratio...

Страница 83: ...e UltraNet Edge 3000 2 Click on the line of text the Broadcast Data that appears in that section to cause the serial number and MAC Address fields to appear 3 Modify the Assign IP Address the Assign N...

Страница 84: ...or allocated and assigned messages These messages will only appear for a brief moment and will indicate if the unit is resetting and booting up When finished booting up the letters PMA will display an...

Страница 85: ...ceeding to the Setting the License Information procedure Setting the License Information The License Key Wizard determines which features can be enabled for your network 1 Right click on Node10 and se...

Страница 86: ...al Number and License Key dialog box appears 3 Enter the serial number and license key for Node10 which are found on the License and Registration Information document P N 30200538 4 Click the Next but...

Страница 87: ...step to set the licensing information for this node 7 Continue the configuration process by proceeding to the Adding an IP Circuit procedure Adding an IP Circuit You will now create an IP circuit A ci...

Страница 88: ...node is in a special configuration mode 4 Click the second node the destination that you want to connect the circuit to The IP Circuit Wizard Introduction dialog box appears This wizard helps you sel...

Страница 89: ...click Next NOTE Use I O port 3 for all 1x1 configurations When configuring a 2x2 use I O port 3 to connect the first circuit and I O port 4 for the second circuit The IP Circuit Wizard Node10 Configu...

Страница 90: ...ick Next The IP Circuit Wizard Node10 Configure Gateway dialog box appears The gateway IP address entered in this dialog box will be the router IP WAN address attached to the UltraNet Edge 3000 Node10...

Страница 91: ...or 2x2 For the 2nd circuit of a 1x2 or 2x2 configuration enter the gateway address labeled 10 Click Next The IP Circuit Wizard Node20 Choose Interface dialog box appears Node20 is the destination nod...

Страница 92: ...dress labeled for the circuit on a 1x1 or 2x1 configuration or the 1st circuit of a 1x2 or 2x2 For the 2nd circuit of a 1x2 or 2x2 configuration enter the IP address labeled 14 Click Next The IP Circu...

Страница 93: ...15 Check Set enter the IP Address of the router directly attached to Node20 to set the static route NOTE If you are using the Configuration IP Address Worksheet enter the following information For Nod...

Страница 94: ...es the minimum and maximum trasnmission rates to dynamically determine bandwidth allocation If a minimum transmission rate is not set or if it is set to the same value as the maximum transmission rate...

Страница 95: ...net Wide Area Network 20 Click Finish Once you have completed the above steps for a basic 1x1 10 100 Ethernet WAN configuration your network map should look like the following example 21 Continue the...

Страница 96: ...nfigManager right click on the FC IP interface the cloud icon for Node10 in the network map The Create Data Path menu is displayed 2 Click the Create Data Paths selection You should see marching ants...

Страница 97: ...1 Ethernet Wide Area Network The Create Data Path Wizard Introduction dialog box appears 4 Click Next The Create Data Path Wizard Choose Network Routing Option dialog box is displayed 5 Select either...

Страница 98: ...for each node in the circuit using the License Wizard only the Dedicated Circuit network routing type is selectable from this dialog box If you want to change the Network Routing Type after you have...

Страница 99: ...ovides network recommendations for E_port Disk Streaming see the E_Port Disk Streaming Network Recommendations section 7 Choose whether you would like to enable the Switch WWN Proxy between Node10 and...

Страница 100: ...changes to the configuration parameters you must deliver the configuration information for each node defined on the active network map to the actual nodes The configuration information can be deliver...

Страница 101: ...ect Properties The Node10 Properties UltraNet Edge 3000 screen appears 2 Click on the drop down menu to select the Delivery Interface 3 The Delivery Interface defines the IP address by which the netwo...

Страница 102: ...the configurations on selected node s Use the following procedure to perform any of these functions on one or more node s 1 Click the File menu then select Delivery Wizard The Delivery Wizard Introduc...

Страница 103: ...nt network map to the node s activates the configuration by copying it into the active directory and then resets the node s Deliver delivers the network map configuration to an offline directory and i...

Страница 104: ...elivered to each node if the configuration passes verification If the current network is unnamed you are prompted to provide a name for it up to eight characters The Network Map must be saved before i...

Страница 105: ...29 Delivering the Configured Network warnings or error messages You will see a message like the following Click OK The UltraNet ConfigManager Log txt screen will automatically appear listing the Conf...

Страница 106: ...5 5 30 McDATA UltraNet Edge 3000 User Guide Delivering the Configured Network...

Страница 107: ...d configurations for the UltraNet Edge 3000 Prior to configuring the UltraNet Edge 3000 you should be familiar with Fibre Channel 10 100 Ethernet and Gigabit Ethernet networking principles You will ne...

Страница 108: ...Appendix J will be used as examples in the configuration process Figure 6 1 shows an example of a network configured with two UltraNet Edge 3000s as a 2x2 implementation Figure 6 1 Sample F_port Ethe...

Страница 109: ...witch FCSW application is used instead of an external Fibre Channel switch NOTE For more detail on valid configuration options see the Valid Hardware Interface Configurations section in Chapter 2 Star...

Страница 110: ...ion This configuration will have two nodes that extend two Fibre Channel Switch FCSW interfaces over two Gigabit Ethernet WANs NOTE When configuring a 2x2 the Ethernet Maintenance Interface and both W...

Страница 111: ...operation 3 Click in the Network Map Area to create an instance of the UltraNet Edge 3000 node Adding a Fibre Channel Interface If this is the first time you are adding an UltraNet Edge 3000 node to...

Страница 112: ...Switch F_port If you have previously added an UltraNet Edge 3000 node and need to change the default Fibre Channel interface type click the Tools menu then Options and select the appropriate interface...

Страница 113: ...bered 10 2 and the Fibre Channel Switch interface on Node 20 would be numbered 20 2 Setting the Initial Configuration If you configured an UltraNet Edge 3000 custom chassis in Chapter 4 continue the c...

Страница 114: ...uests The broadcast data only appears the first time you configure when the Alphanumeric messages window displays BOTP on the front of the UltraNet Edge 3000 see Figure 2 4 in Chapter 2 2 Click on the...

Страница 115: ...et Edge 3000 4 Click Apply to enable the maintenance interface UltraNet ConfigManager will load the IP address information into the UltraNet Edge 3000 and will reboot NOTE Watch the UltraNet Edge Conf...

Страница 116: ...age Router Technical Documentation Library CD titled Manual Configuration of the Initial IP Settings 5 Repeat step 1 through step 4 for the second node Node 20 6 Continue the configuration process by...

Страница 117: ...lick the Next button The License Wizard Serial Number and License Key dialog box appears 3 Enter the serial number and license key for Node10 which are found on the License and Registration Informatio...

Страница 118: ...gh step 4 to set the licensing information for this node 6 Continue the configuration process by proceeding to the Adding an IP Circuit procedure Adding an IP Circuit You will now create an IP circuit...

Страница 119: ...the first node to create an IP circuit in this example Node10 This will cause marching ants to highlight the area around the node icon indicating that the node is in a special configuration mode 4 Cl...

Страница 120: ...rface for each node and configure the circuit 5 Click Next The IP Circuit Wizard Node10 Choose Interface dialog box appears The drop down menu displays the available IP interface providers in the Ultr...

Страница 121: ...P WAN address and the Subnet Mask The IP WAN address must be different from the Ethernet maintenance interface address NOTE If you are using the Configuration IP Address Worksheet from Appendix J ente...

Страница 122: ...outes at a later time see Appendix E Static Routes 9 Check Set enter the IP Address of the router directly attached to the IP WAN interface of Node10 to set the static route NOTE If you are using the...

Страница 123: ...opriate IP interface provider 12 Click Next NOTE Use I O port 3 for all 1x1 configurations When configuring a 2x2 use I O port 3 to connect the first circuit and I O port 4 for the second circuit The...

Страница 124: ...on a 1x1 or 2x1 configuration or the 1st circuit of a 2x2 or 1x2 For the 2nd circuit of a 2x2 or 1x2 configuration enter the IP address labeled 14 Click Next The IP Circuit Wizard Node20 Configure Gat...

Страница 125: ...Set enter the IP Address of the router directly attached to Node20 to set the static route NOTE If you are using the Configuration IP Address Worksheet from Appendix J enter the following information...

Страница 126: ...t the defaults For optimal performance the Maximum Transmission Rate should be set to 92 of the speed of your slowest network segment The IP Circuit Wizard Finish dialog box is displayed indicating th...

Страница 127: ...a connection between the Fibre Channel Switch interfaces by creating a data path The following example illustrates the creation of a data path for a 2x2 configuration where each node has a 2 port Fibr...

Страница 128: ...ta path between the Fibre Channel Switch interfaces 1 Right click the Fibre Channel Switch interface 10 the cloud icon on Node 10 in the Network Map The Create Data Path menu is displayed 2 Select Cre...

Страница 129: ...h Destinations dialog appears 5 Select the destination for which you want to create data path by checking the box next to the destination 6 Click the Next button The FC Switch DataPath Wizard Network...

Страница 130: ...te Data Path Wizard Choose Data Path Options dialog is displayed Otherwise skip to step 9 Check the Enable Disk Streaming box if you want to enable Disk Streaming for the interfaces The Enable Disk St...

Страница 131: ...The Network Map should now look similar to this If you are creating a 1x1 configuration the only selectable routing type is Dedicated Circuit If you are creating a 2x2 configuration with FC Switch int...

Страница 132: ...nge the Network Routing Type If you have not entered the licensing information for each node in the circuit using the License Wizard only the Dedicated Circuit network routing type is selectable from...

Страница 133: ...ry Interface The Delivery Interface defines the IP address by which the network map will be delivered 3 Select the desired option to deliver the network map configurations to the node s 4 Click OK 5 R...

Страница 134: ...ing the Configured Network The Delivery Wizard Introduction screen appears 2 Click Next The Delivery Wizard Select Nodes screen appears 3 Select which node s you would like to deliver and click Next T...

Страница 135: ...to the node s activates the configuration by copying it into the active directory and then resets the node s Deliver delivers the network map configuration to an offline directory and is saved for act...

Страница 136: ...each node if the configuration passes verification If the current network is unnamed you are prompted to provide a name for it up to eight characters The Network Map must be saved before it can be del...

Страница 137: ...Extension over an Ethernet WAN 6 31 Delivering the Configured Network 1 Click OK 2 The UltraNet ConfigManager Log txt screen will automatically appear listing the Configuration Warnings and Error Mes...

Страница 138: ...6 6 32 McDATA UltraNet Edge 3000 User Guide Delivering the Configured Network...

Страница 139: ...u will need to gather some IP addresses for the IP Management feature when configuring an ATM WAN See the UltraNet Edge Storage Router ATM WAN Configuration Worksheet in Appendix J Configuring a 1x1 A...

Страница 140: ...WAN implementation Figure 7 1 Sample E_port 1x1 ATM WAN with two UltraNet Edges Using the ATM WAN Configuration Worksheet from Appendix J gather the IP addresses associated subnet masks and other cri...

Страница 141: ...the Online Tutorial when you first open the UltraNet ConfigManager software You can use either the Online Tutorial or this chapter of the UltraNet Edge Storage Router User Guide to create a sample ne...

Страница 142: ...he current operation 3 Click in the Network Map Area to create an instance of the UltraNet Edge 3000 node Adding a Fibre Channel Interface If this is the first time you are adding an Edge node to the...

Страница 143: ...the cursor to another part of the map and click a second time to create a second instance of the same type of node Your screen should look like the example below UltraNet ConfigManager automatically a...

Страница 144: ...figuration the PC which has UltraNet ConfigManager installed on it must be attached to the same subnet as the UltraNet Edge Storage Router Ethernet maintenance interface If this is not possible refer...

Страница 145: ...IP address has been set This option can be set only once However if you need to change the Maintenance Port IP address after you set the initial configuration see Maintenance Port IP Configuration 2 C...

Страница 146: ...elnet into it NOTE Watch the UltraNet Edge Configuration Status field for allocated and assigned messages These messages will only appear for a brief moment and will indicate if the unit is resetting...

Страница 147: ...Storage Router Technical Documentation Library CD titled Manual Configuration of the Initial IP Settings 5 Repeat step through step for the second node Node 20 6 Continue the configuration process by...

Страница 148: ...utton The License Wizard Serial Number and License Key dialog box appears 3 Enter the serial number and license key for Node10 These numbers are found on the License and Registration Information docum...

Страница 149: ...ng information for this node 7 Continue the configuration process by proceeding to the Adding an ATM Circuit procedure Adding an ATM Circuit You will now create an ATM circuit A circuit is the ATM WAN...

Страница 150: ...in a special configuration mode 4 Click the second node the destination that you want to connect the circuit to The ATM Circuit Wizard Introduction dialog box appears This wizard helps you select and...

Страница 151: ...e appropriate ATM interface provider for Node 10 NOTE Select ATM in I O port 3 for the first circuit If you are configuring a 2x2 select ATM in I O port 4 for the second circuit 7 Click Next The ATM C...

Страница 152: ...used for this protocol a Enter the Virtual Path ID VPI The value that can be entered in this field is determined by the Active VCI Bits value Initially the Active VCI Bits Value is set to 11 only 0 an...

Страница 153: ...lity of Service from the drop down menu CBR Constant Bit Rate VBR Variable Bit Rate UBR Unspecified Bit Rate NOTE McDATA recommends using CBR for ATM implementations The best performance obtained duri...

Страница 154: ...ontracts The aggregate of all SCRs for a particular interface cannot exceed the line rate 1 through 135000 bits sec 1 352 cells sec are valid enabled values This value matches the value specified in t...

Страница 155: ...a 1x1 or 2x1 configuration enter the IP Management address labeled for Node10 For a 2x2 or 1x2 configuration enter the IP Management address labeled for Node10 The IP address must be different than t...

Страница 156: ...propriate ATM interface provider for Node 20 NOTE Select ATM in I O port 3 for the first circuit If you are configuring a 2x2 select ATM in I O port 4 for the second circuit 12 Click Next The ATM Circ...

Страница 157: ...etting is 0 b Enter the Virtual Channel ID VCI The value that can be entered in this field is determined by the Active VCI Bits value Initially the Acitve VCI Bits value is set to 11 valid enabled VCI...

Страница 158: ...the 103 cells sec and 106 bits sec buttons will toggle the entered values between the Kcells per second and Mbps per second formats The 103 cells sec option is the default selection so when you reopen...

Страница 159: ...st Size cells sec in this field 0 through 2812 cells sec are valid enabled values The default value is 0 cells sec This field is only selectable if VBR is selected as the Quality of Service type If UB...

Страница 160: ...ox appears This dialog box enables you to configure the circuit properties 16 To enable the Adaptive Rate Limiting feature check the Minimum box and specify the minimum transmission rate The minimum t...

Страница 161: ...uit The Maximum Transmission Rate and compression features are limited by the license key for the node The MTR value cannot exceed what is specified by the license key 19 Click Next to accept the defa...

Страница 162: ...t you need to establish a connection between the FC IP interfaces by creating a data path This procedure will complete the configuration process Once you have configured the IP circuit your screen sho...

Страница 163: ...hs selection You should see marching ants outlining the FC IP interface 3 Double click on the destination FC IP interface the cloud icon for Node20 in the network map The Create Data Path Wizard Intro...

Страница 164: ...key does not provide support for the Fail Over and Load Balancing network routing types only the Dedicated Circuit network routing type is selectable and all other options on this dialog are grayed ou...

Страница 165: ...bled by default the box is not checked To verify if E_port Disk Streaming has been enabled after the network has been configured refer to the E_Port Disk Streaming Settings section in Appendix D Advan...

Страница 166: ...gn Criteria 7 Select either Enable Disk Streaming and or Enable Switch WWN Proxy to enable this functionality 8 Click Next The Create Data Path Wizard Finish dialog box appears 9 Click Finish to compl...

Страница 167: ...7 Configuring an E_Port Extension over an ATM WAN 7 29 Configuring a 1x1 ATM Wide Area Network 10 Proceed to the Delivering the Configured Network section in this chapter...

Страница 168: ...use the PPP option See Setting the Delivery Properties below NOTE If you used the Manual Configuration of the Initial IP Settings procedure in Appendix H complete the Update UltraNet ConfigManager wit...

Страница 169: ...ry Wizard or the Deliver Network option below Delivery Wizard The Delivery Wizard delivers activates and resets the configurations on selected node s Use the following procedure to perform any of thes...

Страница 170: ...screen appears 4 Select the delivery option you would like to perform on the selected node s Deliver Activate and Reset delivers the current network map to the node s activates the configuration by c...

Страница 171: ...e to deliver the configuration files with the Deliver Network option 1 Click the File menu 2 Select Deliver Network to deliver your configurations The configuration information on the network map is a...

Страница 172: ...tomatically verify the files If the verification passed with warnings or if it failed you will be prompted to view the Log file for warnings or error messages You will see a message like the following...

Страница 173: ...r your UltraNet Edge 3000 to configure an Ethernet WAN See the UltraNet Edge Storage Router Configuration IP Address Worksheet in Appendix J Configuring a 1x1 Ethernet Wide Area Network To configure y...

Страница 174: ...shows an example of a network configured with two UltraNet Edge 3000s as a 2x2 implementation Figure 8 1 Sample FICON ISL with Ethernet WAN using two UltraNet Edge 3000s Using the Configuration IP Add...

Страница 175: ...ce Configurations section in Chapter 2 Starting UltraNet ConfigManager This section explains how to start the UltraNet ConfigManager software and provides information about the UltraNet ConfigManager...

Страница 176: ...tion This configuration will have two nodes that extend one Fibre Channel interface over one Gigabit Ethernet WAN NOTE If you are configuring a 2x2 the Ethernet Maintenance Interface and both WAN inte...

Страница 177: ...if the first time you are adding an UltraNet Edge 3000 node to the Network Map the Default Fibre Channel Interface Type drop down list will appear Select the type of Fibre Channel interface for the ne...

Страница 178: ...nd select the appropriate interface type from the drop down list 4 Move the cursor to another part of the map and click a second time to create a second instance of the same type of node Your map shou...

Страница 179: ...g the Initial Configuration procedure NOTE When you are performing this part of the configuration the PC which has UltraNet ConfigManager installed on it must be attached to the same subnet as the Ult...

Страница 180: ...hat section to cause the serial number and MAC Address fields to appear 3 Modify the Assign IP Address the Assign Netmask address and the Assign Gateway address in the middle of the dialog box to the...

Страница 181: ...for allocated and assigned messages These messages will only appear for a brief moment and will indicate if the unit is resetting and booting up When finished booting up the letters PMA will display...

Страница 182: ...tion procedure Setting the License Information The License Key Wizard determines which features can be enabled for your network 1 Right click on Node10 and select Set License Info from the menu that a...

Страница 183: ...key for Node10 which are found on the License and Registration Information document Click the Next button NOTE If you need more detailed help see the License Wizard section in the UltraNet ConfigMana...

Страница 184: ...tween Node10 and Node20 Use the IP Circuit Wizard to create and configure the IP circuit by using the following procedure 1 Select the Links tab on the center toolbar 2 Click the IP icon on the center...

Страница 185: ...e for each node and configure the circuit 5 Click Next The IP Circuit Wizard Node10 Choose Interface dialog box appears The drop down menu displays the available IP interface providers in the UltraNet...

Страница 186: ...P WAN address and the Subnet Mask The IP WAN address must be different from the Ethernet maintenance interface address NOTE If you are using the Configuration IP Address Worksheet enter the following...

Страница 187: ...later time see Appendix E Modifying Static Routes 9 Check Set enter the IP Address of the router directly attached to the IP WAN interface of Node10 to set the static route NOTE If you are using the...

Страница 188: ...IP interface provider 12 Click Next NOTE Use I O port 3 for all 1x1 configurations When configuring a 2x2 use I O port 3 to connect the first circuit and I O port 4 for the second circuit The IP Circu...

Страница 189: ...x1 configuration or the 1st circuit of a 1x2 or 2x2 For the 2nd circuit of a 1x2 or 2x2 configuration enter the IP address labeled 14 Click Next The IP Circuit Wizard Node20 Configure Gateway dialog b...

Страница 190: ...Check Set enter the IP Address of the router directly attached to Node20 to set the static route NOTE If you are using the Configuration IP Address Worksheet enter the following information For Node20...

Страница 191: ...e minimum and maximum trasnmission rates to dynamically determine bandwidth allocation If a minimum transmission rate is not set or if it is set to the same value as the maximum transmission rate the...

Страница 192: ...N configuration your network map should look like the following example 21 Continue the configuration process by following the Creating a FICON Data Path section in this chapter Creating a FICON Data...

Страница 193: ...con for FICON10 in the network map The Create Data Path menu is displayed 2 Click the Create Data Paths selection You should see marching ants outlining the FICON interface 3 Double click on the desti...

Страница 194: ...Path Wizard Choose Network Routing Option dialog box is displayed 5 Select either Dedicated Circuit Fail Over or Load Balancing in the Network Routing Options If you are creating a 1x1 configuration...

Страница 195: ...dialog box If you want to change the Network Routing Type after you have created the data paths double click the F C interface on the Network Map Click the Network button at the bottom of the F C int...

Страница 196: ...tes the procedure for FICON data path mapping Using the FICON Global Settings Wizard You may use the FICON Global Settings Wizard to configure the settings for FICON interfaces These configuration set...

Страница 197: ...ot run the FICON Global Settings Wizard The selections you make in this dialog will determine which subsequent FICON Global Settings Wizard dialogs are displayed For instance if you check the FICON Ta...

Страница 198: ...displays all FICON interfaces that support Tape Write Pipelining in the network Additionally this dialog displays the current Tape Write Pipelining configuration information for the FICON interface Us...

Страница 199: ...ve devices The default value is 8 Write Timer ms In this field enter a time limit for pipelined write chains This value must be specified in milliseconds ms If a pipelined write chain takes longer tha...

Страница 200: ...ould be enabled on this interface If a data path is mapped for this interface UltraNet ConfigManager ensures that the Tape Read Pipelining option is also enabled on the peer interface Max Read In this...

Страница 201: ...lues for the Edge nodes you selected in the previous dialog Set Check the Set box to enter value for the parameter displayed to the right The value in the corresponding field is only used if the Set b...

Страница 202: ...he selected USD X PPC adapters The Transport Window Size determines the number of buffers that can be outstanding in the network for each transport connection associated with the selected USD X PPC Ad...

Страница 203: ...s File Deliver Network or File Delivery Wizard The configurations can be delivered via the Maintenance Port IP or the PPP Port IP If you do not have direct IP connectivity use the PPP option See Setti...

Страница 204: ...eps for the other node s 6 Deliver the network map configurations by either the Delivery Wizard or the Deliver Network option below Delivery Wizard The Delivery Wizard delivers activates and resets th...

Страница 205: ...s 4 Select the delivery option you would like to perform on the selected node s and then click Next Deliver Activate and Reset delivers the current network map to the node s activates the configuratio...

Страница 206: ...to deliver the configuration files with the Deliver Network option 1 Click the File menu 2 Select Deliver Network to deliver your configurations The configuration information on the Network Map is aut...

Страница 207: ...tically verify the files If the verification passed with warnings or if it failed you will be prompted to view the Log file for warnings or error messages You will see a message like the following 1 C...

Страница 208: ...8 8 36 McDATA UltraNet Edge 3000 User Guide Delivering the Configured Network...

Страница 209: ...on of the supported configurations refer to Chapter 2 Hardware Configurations in this guide Throughout the remainder of this chapter Tape Device Extension is referred to as FC SCSI Tape Pipelining Set...

Страница 210: ...ry and LUN Mapping section in Chapter 10 for an understanding of the Edge s functionality before attempting to configure your network Example of Uni directional Configuration No Zoning Figure 8 1 prov...

Страница 211: ...termine when zoning is necessary Figure 9 2 Bi directional FC SCSI Tape Pipelining with Zoning Sb043 Server A Server B UltraNet Edge Storage Router Node 10 UltraNet Edge Storage Router Node 20 Media C...

Страница 212: ...red Static Edge LUN Mapping section Table 8 4 and Table 8 5 page 7 define the static Edge LUN mapping for nodes 10 and 20 Figure 9 3 Bi directional FC SCSI Tape Pipelining Zoning and Optional LUN Mapp...

Страница 213: ...LUN mapping to configure a remote target LUN the automatic LUN discovery function is disabled for that target This allows a method for zoning remote LUNs available through this pair of Edges A configu...

Страница 214: ...ipelining section in Chapter 13 World Wide Name Table Table 8 3 shows a fictitious World Wide Name WWN for each device These WWNs are used in the static LUN mapping examples shown in Table 8 4 and Tab...

Страница 215: ...ection require source WWN filtering to isolate servers from specific devices that are being channel extended Examples of Source WWN Filtering Table 8 6 and Table 8 7 are examples of how the devices sh...

Страница 216: ...tion the following eight procedures are necessary Complete each procedure in the order shown below 1 Gathering the IP Addresses 2 Starting UltraNet ConfigManager 3 Adding Nodes for an Ethernet WAN Con...

Страница 217: ...be used as references to determine when Fibre Channel switch zoning statically mapping the LUNs and source WWN filtering are required If your network requires static mapping or source WWN filtering p...

Страница 218: ...anager Online Tutorial The UltraNet ConfigManager UCM application is used to configure the UltraNet Edge 3000 You will have the option to use the Online Tutorial when you first open the UCM software Y...

Страница 219: ...8 4 on page 11 The Nodes tab displays three drop down menus Each contains the node types for the available Edge series 2 Click the arrow next to the UltraNet Edge 3000 Series drop down menu and select...

Страница 220: ...Fibre Channel I F default This sets the type of Fibre Channel interface as the default UltraNet ConfigManager will use in each configuration unless you change it When configuring Device Extension ove...

Страница 221: ...When you are performing this part of the configuration the PC which has UltraNet ConfigManager installed on it must be attached to the same subnet as the UltraNet Edge 3000 Ethernet maintenance inter...

Страница 222: ...ection to cause the serial number and MAC Address fields to appear 3 Modify the Assign IP Address the Assign Netmask address and the Assign Gateway address in the middle of the dialog box to the maint...

Страница 223: ...Configuration Status box for allocated and assigned messages These messages will only appear for a brief moment and will indicate if the unit is resetting and booting up When finished booting up the...

Страница 224: ...n procedure Setting the License Information The License Key Wizard determines which features can be enabled for your network 1 Right click on Node10 and select Set License Info from the menu that appe...

Страница 225: ...ration Information document Click the Next button NOTE If you need more detailed help see the License Wizard section in the UltraNet ConfigManager Online Help The License Wizard Finish dialog box appe...

Страница 226: ...e and configure the IP circuit by using the following procedure 1 Select the Links tab on the center toolbar 2 Click the IP icon on the center toolbar 3 Click the first node to create an IP circuit in...

Страница 227: ...ard helps you select and configure an interface for each node and configure the circuit 5 Click Next The IP Circuit Wizard Node10 Choose Interface dialog box appears The drop down menu displays the av...

Страница 228: ...WAN interface properties for Node10 7 Enter the IP Address IP WAN address and the Subnet Mask The IP WAN address must be different from the Ethernet maintenance interface address NOTE If you are using...

Страница 229: ...is at this point you can add the static route at a later time To add static routes at a later time see Appendix A Modifying Static Routes 9 Select Set enter the IP Address of the router directly atta...

Страница 230: ...the drop down arrow and select the appropriate IP interface provider 12 Click Next NOTE Use I O port 3 for all 1x1 configurations The IP Circuit Wizard Node20 Configure Interface dialog box appears Th...

Страница 231: ...r Node20 enter the IP address labeled 14 Click Next The IP Circuit Wizard Node20 Configure Gateway dialog box appears The gateway IP address entered in this dialog box will be the router IP address at...

Страница 232: ...add static routes at a later time see Appendix A Modifying Static Routes 15 Select Set enter the IP Address of the router directly attached to Node20 to set the static route NOTE If you are using the...

Страница 233: ...pt the defaults For optimal performance the Maximum Transmission Rate should be set to 92 of the speed of your slowest network segment The IP Circuit Wizard Finish dialog box is displayed indicating t...

Страница 234: ...onfiguration process by following the Creating a Data Path for Fibre Channel Device Extension Interfaces section in this chapter Creating a Data Path for Fibre Channel Device Extension Interfaces Afte...

Страница 235: ...Click the Create Data Paths selection You should see marching ants outlining the Fibre Channel Device Extension 3 Double click on the destination Fibre Channel Device Extension interface 20 on Node 20...

Страница 236: ...tension 4 Click Next The FC Device Extension DataPath Wizard Automatic DataPath Mapping dialog box appears 5 Enter the number of data path entries that you would like configured on Fibre Channel Devic...

Страница 237: ...target connects to hosts and the Edge initiator connects to tape devices NOTE The number entered into the Number of New Entries field specifies the maximum number of devices that can be automatically...

Страница 238: ...e the target and node 10 the initiator The Edge target connects to hosts and the Edge initiator connects to tape devices If both check boxes for node 10 and 20 are selected both Edge nodes are targets...

Страница 239: ...ated Circuit network routing type is selectable and all other options on this dialog are grayed out If you want to change the Network Routing Type after you have created the data paths double click th...

Страница 240: ...ing the Source WWN Use the following procedure to statically map the Edge LUNs and add filtering to the source WWN Use Table 8 4 and Table 8 5 page 7 for an example of how the LUNs and WWNs are used i...

Страница 241: ...ro in the LUN field See Table 8 5 page 7 and the screen below for an example 4 Click OK 5 Double click on the Device Extension interface 20 on Node 20 6 Click the Host tab 7 Click in the Dest WWN LUN...

Страница 242: ...box Selecting the Show Source WWN Filtering check box enables the Source WWN field to show up on the Host tab 11 Select the Discover LUN Count from the drop down menu This value determines the range...

Страница 243: ...Address Type drop down menu 13 From the LUN 0 drop down menu select either Emulate or Passthru Show Source WWN Filtering Select Fibre Channel Topology Discover LUN Count LUN 0 Soft The Fibre Channel...

Страница 244: ...s WWN Emulate LUN 0 is statically configured as a local McDATA controller This mode results in the Report LUNs command being intercepted and an inventory being generated based on the UltraNet configur...

Страница 245: ...ng applied 17 Click OK Mapping Node 20 to WWNs Accessed by Node 10 1 Double click on the Device Extension interface 20 on Node 20 2 Click the Peripheral tab and define the WWNs accessed by Node 10 in...

Страница 246: ...evice Extension 4 Click OK 5 Double click on the Device Extension interface 10 on Node 10 6 Click the Host tab 7 Click in the Dest WWN LUN field to map the 1st LUN to node 20 The field turns into a dr...

Страница 247: ...ox Selecting the Show Source WWN Filtering check box enables the Source WWN field to show up on the Host tab 11 Select the Discover LUN Count from the drop down menu This value determines the range of...

Страница 248: ...e Address Type drop down menu 13 From the LUN 0 drop down menu select either Emulate or Passthru Show Source WWN Filtering Select Fibre Channel Topology Discover LUN Count LUN 0 Soft The Fibre Channel...

Страница 249: ...WWN Emulate LUN 0 is statically configured as a local McDATA controller This mode results in the Report LUNs command being intercepted and an inventory being generated based on the UltraNet configura...

Страница 250: ...a sample network or if you made changes to the configuration parameters you must deliver the configuration information for each node defined on the active network map to the actual nodes The configura...

Страница 251: ...ars where 1000 refers to the Edge model number 2 Click on the drop down menu to select the Delivery Interface The Delivery Interface defines the IP address by which the network map will be delivered 3...

Страница 252: ...3000 User Guide Delivering the Configured Network 2 Click Next The Delivery Wizard Select Nodes screen appears 3 Select which node s you would like to deliver and click Next The Delivery Wizard Selec...

Страница 253: ...iguration by copying it into the active directory and then resets the node s Deliver delivers the network map configuration to an offline directory and is saved for activation at a later time Activate...

Страница 254: ...figuration passes verification If the current network is unnamed you are prompted to provide a name for it up to eight characters The Network map must be saved before it can be delivered When the conf...

Страница 255: ...Tape Device Extension 9 47 Delivering the Configured Network 1 Click OK 2 The UltraNet ConfigManager Log txt screen will automatically appear listing the Configuration Warnings and Error Messages in t...

Страница 256: ...9 9 48 McDATA UltraNet Edge 3000 User Guide Delivering the Configured Network...

Страница 257: ...The following sections discuss how buffering emulation and error recovery work Buffering and Emulation Before addressing the impact of device emulation on tape backup it is helpful to understand how b...

Страница 258: ...red devices completion status simply means that the operation was transferred to the device controller and is safely stored in the device s buffer Device Error Recovery Since natively attached buffere...

Страница 259: ...s the Fibre Channel port on the UltraNet Edge 3000 as an N_port or NL_port allowing direct connections to Fibre Channel F_ports and FL_Ports Fibre Channel switches or Fibre Channel N_ports or NL_ports...

Страница 260: ...ingle target with multiple LUNs When LUN 0 is configured in Emulate mode it will appear as a device type controller When LUN 0 is configured in Passthru mode it will represent an actual remote device...

Страница 261: ...he ttag user interface If any new LUNs are discovered those LUNs will be added to the host LUN table if an open host LUN field is available Existing LUNs already discovered to any remote targets will...

Страница 262: ...unless the user releases the purged list Any newly discovered remote targets will be dynamically bound to the Edge target LUN mapping replacing the purged WWNs Releasing the purged list will allow th...

Страница 263: ...s The McDATA 2 1 specific MIB provides partial support of a compatible grouping of RFC 2233 Extended interface It also supports a partial grouping of FCMGMT MIB Fibre Channel mib version 4 0 as an exp...

Страница 264: ...nt version for the UltraNet Edge 3000 OS The last module listed shows the current version of WebView Upgrading the UltraNet Edge 3000 On Site Local This section explains all of the steps required to r...

Страница 265: ...TE An on site hardware replacement can be initiated using the UltraNet Edge 3000 s serial interface with the McDATA supplied serial cable If this is preferred over Ethernet connectivity use the Upgrad...

Страница 266: ...Net Edge 3000 and invoke the new configurations 2 Telnet to the UltraNet Edge 3000 that is currently running OS 3 1 1 1 or any subsequent 3 x x x version Where xxx the version of the UltraNet Edge 300...

Страница 267: ...what has been defined for the node The prom default password is shadow 4 Press ENTER to get into prom mode 5 Issue the tartoc filename command to display a listing of the files within the tar archive...

Страница 268: ...just been upgraded The UltraNet Edge 3000 will be rebooted after a successful delivery Upgrading the UltraNet Edge 3000 Remote Dial up This section explains all of the steps required to replace the c...

Страница 269: ...000 Unit Use the following procedure to power down the UltraNet Edge 3000 1 Direct the on site technician to power off the UltraNet Edge 3000 that is being replaced 2 Direct the on site technician to...

Страница 270: ...ware Use the following procedure to FTP to the new UltraNet Edge 3000 and retrieve the new software 1 Telnet to the new UltraNet Edge 3000 and issue the abort command This will boot up the UltraNet Ed...

Страница 271: ...d stop the boot process at the prom Press ENTER as soon as the prom prompt is displayed to stop the boot process 3 Issue the tartoc filename command to display a listing of the files within the tar ar...

Страница 272: ...ltraNet Edge 3000 will be rebooted after a successful delivery Upgrading Edge Software from 3 1 1 1 or Higher This procedure only applies to software upgrades and should not be used when it is necessa...

Страница 273: ...e disk using the remove file command 8 Issue the tarExtract vx_tar tar 0 command at the prom prompt Wait for the prom prompt to return before proceeding to step 9 After the tarExtract command is compl...

Страница 274: ...Browser and System Requirements for WebView UltraNet WebView has been tested on the following operating systems and browsers View the ReadMe file for Java plug in information once you ve accessed the...

Страница 275: ...oot directory 1 Use the FTP protocol to download the software from your PC to the UltraNet Edge 3000 2 FTP the UltraNet WebView software rpm file from your PC to the root directory of the UltraNet Edg...

Страница 276: ...upgrading WebView the webserver needs to be restarted so it can flush all the old WebView information and load the new information from the current WebView program 4 Issue the ews reinit command at t...

Страница 277: ...oftware Use the following procedure to install the most current UltraNet ConfigManager software release 1 Obtain the most current UltraNet ConfigManager UCM software release from McDATA Customer Suppo...

Страница 278: ...11 11 16 McDATA UltraNet Edge 3000 User Guide UltraNet ConfigManager Upgrade...

Страница 279: ...the UltraNet Edge 3000 Field Replaceable Units FRUs UltraNet Edge 3000 Chassis Fan Assembly Power Supply Fibre Channel interface card 10 100 Ethernet interface card Gigabit Ethernet interface card OC...

Страница 280: ...eplaceable Units FRUs Replacing the UltraNet Edge 3000 Chassis For replacement purposes when the UltraNet Edge 3000 chassis is referred to it assumes that the following components are included as part...

Страница 281: ...l straight slot screwdriver CAUTION Attach a wrist strap and follow ESD procedures during the handling of all electronic components 1 Remove the unit from the equipment rack if necessary NOTE It is no...

Страница 282: ...connector by lifting up on the plastic latch with a non metallic tool to release the power connector each connector has a black and a red wire Then remove it from the main processing board 7 Place th...

Страница 283: ...fan assembly to a closed position making certain that the screw lines up with the threaded screw hole CAUTION As you swing the new fan assembly to a close position make certain that the power feed wi...

Страница 284: ...es are hot swappable which means an individual power supply can be replaced while the UltraNet Edge 3000 unit is in operation 2 Unplug the faulty power supply s power cord 3 From the front side depres...

Страница 285: ...Remove the new power tray from the antistatic wrapping 2 Place the power tray into the slot and gently slide it back until it is connected to the power distribution board at the back of the UltraNet E...

Страница 286: ...the top cover using the small Phillips screwdriver 5 To remove the top cover you must slide the cover towards the rear of the unit as it is locked into the chassis 6 Follow the Top Cover Installation...

Страница 287: ...hat were made available during the removal procedure Torque to 6 in lbs 3 Reconnect the power cords rear 4 Turn on the power supplies Fibre Channel Interface Card Removal Procedure Use the following p...

Страница 288: ...new Fibre Channel interface card Fibre Channel Interface Card Installation Procedure Use the following procedure to install the Fibre Channel FCBB interface card into the UltraNet Edge 3000 chassis T...

Страница 289: ...e replacement procedures found later in this chapter 10 100 Ethernet Interface Card Removal Procedure Use the following procedure to remove the 10 100 Ethernet interface card from the UltraNet Edge 30...

Страница 290: ...stall the 10 100 Ethernet interface card into the UltraNet Edge 3000 chassis Tools required A small Phillips screwdriver and an adjustable Torque driver rated between 3 and 15 in lbs CAUTION Make sure...

Страница 291: ...mall Phillips screwdriver and an adjustable Torque driver rated between 3 and 15 in lbs CAUTION Attach a wrist strap and follow ESD procedures see page B 19 during the handling of all electronic compo...

Страница 292: ...in lbs CAUTION Make sure the power is off Attach a wrist strap and follow ESD procedures see page B 19 during the handling of all electronic components 1 Carefully insert the Gig E interface card in e...

Страница 293: ...ver rated between 3 and 15 in lbs CAUTION Attach a wrist strap and follow ESD procedures see page B 19 during the handling of all electronic components 1 Follow the Top Cover Removal Procedure 2 Turn...

Страница 294: ...tween 3 and 15 in lbs CAUTION Make sure the power is off Attach a wrist strap and follow ESD procedures see page B 19 during the handling of all electronic components 1 Carefully insert the OC 3 ATM i...

Страница 295: ...short wave transceivers Tools required No special tools are required CAUTION Attach a wrist strap and follow ESD procedures during the handling of all electronic components The transceivers are hot sw...

Страница 296: ...the transceiver To avoid breaking the release tab be careful to push it straight in 3 Pull the transceiver out of the interface card Removing the Black Metal Clasp Transceiver 1 Remove the fiber optic...

Страница 297: ...g E Short Wave SFP Transceiver Use the installation procedure below to install all variations of the Gig E short wave transceivers Installing the Red Plastic Tab Transceiver 1 Carefully position the l...

Страница 298: ...2 12 20 McDATA UltraNet Edge 3000 User Guide Replacing the Gigabit Ethernet Short Wave Transceiver Installing the Black Metal Clasp Transceiver Installing the Plain Metal Clasp Transceiver Sb053 Sb126...

Страница 299: ...he Gig E Long Wave SFP Transceiver The long wave transceiver for the Gig E interface card has a blue metal clasp shown below Use the following procedure to remove the transceiver from the interface ca...

Страница 300: ...for the Gig E interface card has a blue metal clasp shown below Use the following procedure to install the transceiver into the interface card Installing the Blue Metal Clasp Transceiver 1 Carefully...

Страница 301: ...while the Edge unit is in operation Removing the Gig E Copper Transceiver There is only one type of Copper transceiver used for the Gig E interface card use the following procedure for removal 1 Remo...

Страница 302: ...eiver There is only one type of Copper transceiver used for the Gig E interface card use the following procedure to install it into the interface card 1 Carefully position the copper transceiver to in...

Страница 303: ...ATM Short Wave SFP Transceiver Use the following procedure to remove the short wave OC 3 ATM transceiver from the right port of the interface card Although the OC 3 ATM interface card currently has tw...

Страница 304: ...er into the right port of the interface card Although the OC 3 ATM interface card currently has two physical ports only the right port is functional Installing the Plain Metal Clasp Transceiver 1 Care...

Страница 305: ...TM Long Wave SFP Transceiver The OC 3 ATM long wave transceiver has a blue plastic body with a plain metal clasp Use the following procedure to remove the transceiver from the interface card Removing...

Страница 306: ...as a blue plastic body with a plain metal clasp Use the following procedure to install the transceiver into the interface card Installing the Plain Metal Clasp Transceiver 1 Carefully position the lon...

Страница 307: ...dge 3000 unit is in operation Removing the Fibre Channel Short Wave SFP Transceiver Use the removal procedure below that corresponds with the type of transceiver you are removing Removing the Black Me...

Страница 308: ...to release the transceiver To avoid breaking the release tab be careful to push it straight in 3 Pull the transceiver out of the interface card Installing the Fibre Channel Short Wave SFP Transceiver...

Страница 309: ...cing the Fibre Channel Short Wave Transceiver Installing the Black Metal Clasp Transceiver NOTE This black metal clasp transceiver is also used with the FCXL2 interface card Installing the Black Plast...

Страница 310: ...g wave Fibre Channel transceiver has a blue plastic tab Use the following procedure to remove the long wave transceiver from the interface card Removing the Blue Plastic Tab Transceiver 1 Remove the f...

Страница 311: ...Use the following procedure to install the long wave Fibre Channel transceiver into the interface card Installing the Blue Plastic Tab Transceiver 1 Carefully position the long wave transceiver to ins...

Страница 312: ...12 12 34 McDATA UltraNet Edge 3000 User Guide Replacing the Fibre Channel Long Wave Transceiver...

Страница 313: ...apter 2 for information regarding LEDs Network Design Verify that the IP addresses subnet masks static routes and the default gateway are correct Ensure that the IP host addresses for all of the Ultra...

Страница 314: ...command will show every possible command that can be typed at the main menu prompt Some commands will enter into their own user interface with their own submenu of commands When you enter into anothe...

Страница 315: ...ircuit is not established with the peer node 1 If the circuit status is down first check the physical interface to make sure the interface link is up See either the AMDENET 10 100 WAN or Maintenance I...

Страница 316: ...outer AMDENET 10 100 WAN or Maintenance Interface The AMDENET user interface provides statistical and informational data pertaining to all the Ethernet interfaces For further information on the AMDENE...

Страница 317: ...full duplex TX interrupts 1041 Broadcast frames sent 125 Ethernet frames sent 1041 TX queue length 1 Total frames sent 1041 Total bytes sent 126238 RX interrupts 1066 Unicast frames received 1066 Uni...

Страница 318: ...ast frames received 3372 Unicast bytes received 331099 Broadcast frames received 11834 Broadcast bytes received 4971868 802 3 frames received 10124 Total frames received 15206 Total bytes received 530...

Страница 319: ...iscards 0 InErrors 0 InUnknownProtos 0 OutOctets 0x0000000000000874 OutUcastPkts 33 OutMulticast 0 OutBroadcast 0 OutDiscards 0 OutErrors 0 DiscontinuityTime 0 RX packet 64 bytes 1 RX packets 65 127 b...

Страница 320: ...and clears the backbone trace for one or all Fibre Channel instances clear batch_stats This command clears the interface batching statistics or one or all Fibre Channel instances clear ints This comma...

Страница 321: ...been enabled the screen display would look similar to the following tm 0x10 fccnt dump proxy Instance 1 Device 0 Device 0 Proxy enabled yes Local SwitchName 10 00 00 60 69 22 1c f3 Remote SwitchName 1...

Страница 322: ...mmands refer to the FCSW Commands chapter in the UltraNet Edge Storage Router Command Reference The following sections highlight the commands useful for troubleshooting fcsw cache This command display...

Страница 323: ...EADY batching limit is 3 flow control is OFF NOTE Passthrough mode indicates that you have a good E_port connection Example of the fcxl2 dump backbone command screen display showing a missing connecti...

Страница 324: ...ce SUPPORT The support command is an all in one command It should be used when a problem needs to be escalated to McDATA for support support o filename Once the support o command is issued the followi...

Страница 325: ...ng failure V020 Shell initialization failure VXOK Kernel ok V020 V027 Network protocol initialization failed V028 V030 unused V030 Can t load network config info from NVRAM or BOOTP failure V031 V037...

Страница 326: ...ed in to a Switch but instead plugged directly into a server or device make sure the server or device is configured for Public or Private Loop If you are directly connecting a server or device into th...

Страница 327: ...ommand to inspect the UltraNet Edge 3000 s FC SCSI Tape Pipelining LUN map b If reordering is required issue the ttag wwnPurg 2 all command This command removes all dynamically discovered entries from...

Страница 328: ...le entries from the table however the ttag wwnRel command will only allow a release of a WWN which will cause the UltraNet Edge 3000 to re discover all the devices attached to that WWN See the Static...

Страница 329: ...agnostics with a telnet session contact Technical Support for the Prom user name and password see the Regulatory and Safety Statements section in the Chapter Preface Use the following procedure to use...

Страница 330: ...display the size of the program and the loading process Example dll_load diags sbtt dll Enter value 1 0xffffffff int_pri_ptr 0xfe00d47 2 From the prom prompt type start_ xxxx and press the Enter key...

Страница 331: ...ram tests the UltraNet Edge 3000 s CHARM ATM POS WAN interface and verifies that it can perform memory transfer functions across the primary PCI bus and local memory Test data can be looped back eithe...

Страница 332: ...8 Lpbk Incr Byte Test 96 Run All Lpbk Tests 9 Lpbk Incr Packet Test 97 Run All P2P Tests 10 Lpbk Increment VC Test 98 Run All Line Tests 11 Charm Port to Port Test 99 Execute All 99 Test 3 Charm Memor...

Страница 333: ...1 Total Errors 0 Tests Run Parameters 00020600 01000000 40000000 44000000 F0040000 QuickMem 40000000 41000000 42000000 40800000 41800000 42100000 1000 0 1 1020304 Incrementing DMA1 DMA2 ENA_DMA_INT 0...

Страница 334: ...ltraNet Edge 3000 s flash drive as the file fcbb dll Using the PROM interface the file must be loaded into memory and executed from there This program tests the UltraNet Edge 3000 s Fibre Channel modu...

Страница 335: ...rite Patt 55555555 PASSED FC BB TX Queue Data Test passed 1 failed 0 Test 5 FC BB TX Queue Adrs Test running PASSED FC BB TX Queue Adrs Test passed 1 failed 0 PASSED FC BB TX Queue Adrs Test passed 1...

Страница 336: ...UltraNet Edge 3000 10 100 Ethernet diagnostic program resides on the UltraNet Edge 3000 s flash drive as the file e10t dll Using the PROM interface the file must be loaded into memory and executed fr...

Страница 337: ...t Incr Packet Test 96 Run All P2P Tests 10 Port Chained Pkt Test 97 Run All TX Line Tsts 11 P2P Dual Dir Test 98 Run All RX Line Tsts 12 P2P DDir Incr Byte 99 Execute All Loopback 99 Loopback Test run...

Страница 338: ...ir Chained Pkt 1 Set Options 15 TX Line Test 2 Set Parameters 16 RX Line Test 3 Loopback Test 17 TX Ln Incr Byte Test 4 Lpbk Incr Byte Test 18 RX Ln Incr Byte Test 5 Lpbk Incr Packet Test 19 TX Ln Inc...

Страница 339: ...and 7 through 35 for two modules SBTM ZPCM Diagnostic Test Revision 1 1 12 07 2001 MAIN MENU Options SINGLE STOP 0 1 Total Errors 0 Tests Run Parameters 1000 1000 0 1 0 1020304 Incrementing ZPC2 0 B 5...

Страница 340: ...running PASSED Incr Pkt Byte C U Tst passed 1 failed 0 Varied Byte C U Test running PASSED Varied Byte C U Test passed 1 failed 0 Varied Data C U Test running PASSED Varied Data C U Test passed 1 fail...

Страница 341: ...dule and verifies that it can perform memory transfer functions to the local memory and the buffer memory Individual tests can be selected from the menu or the 99 Execute All option can be used to run...

Страница 342: ...following procedure to perform the graceful shutdown 1 At the prompt enter the shutdown command tm 0x10 shutdown 2 The following text will appear on the screen enter yes to continue Are you sure you...

Страница 343: ...equirements for the UltraNet Edge 3000 UltraNet Edge 3000 Chassis Dimensions Table A 1 lists the chassis dimensions of the UltraNet Edge 3000 unit The UltraNet Edge 3000 can be placed in a stand alone...

Страница 344: ...requirements provided in Figure A 1 These clearances do not include space for cables or personnel In addition be sure that the UltraNet Edge 3000 cables do not interfere with other equipment cables F...

Страница 345: ...Class A Electromagnetic Immunity European Communities EN55024 1998 for Electromagnetic Immunity in an IT Environment Limits for Harmonic Current Emissions equipment input current 16 A per phase or eq...

Страница 346: ...o ensure that the UltraNet Edge 3000 functions appropriately The power connector for the UltraNet Edge 3000 is a three pronged plug NEMA 5 15P Table A 4 UltraNet Edge 3000 Power Requirements Type Requ...

Страница 347: ...e on unit placement Unpack and inspect the UltraNet Edge 3000 unit Take an inventory of UltraNet Edge 3000 components Ensure that ESD procedures are followed see Cables and Equipment on page 14 If the...

Страница 348: ...stated in Clearance Requirements in Appendix A Table Top Place the UltraNet Edge 3000 unit on a level stable surface Do not place in direct sunlight or near a heat vent Rack Mount To install the Ultra...

Страница 349: ...ake it impossible to remove 2 Position the UltraNet Edge 3000 unit in the rack It may be necessary to tilt the unit approximately six inches or so to clear the rack mounting rails a 4U opening is need...

Страница 350: ...connection allows you to configure your UltraNet Edge 3000 using the UltraNet ConfigManager application 1 Connect an Ethernet straight through Category 5 cable to the RJ 45 connector labeled Ethernet...

Страница 351: ...ply 1 Connect the appropriate end of both AC power cords to the power connectors on the rear panel of the UltraNet Edge 3000 unit 2 Connect the three pronged NEMA 5 15P end of the power cord to a grou...

Страница 352: ...e interface cards include Fibre Channel FCBB card Ethernet 10 100 Gigabit Ethernet OC 3 ATM NOTE The 10 100 Mbps RJ 45 Ethernet interface located on the front of the UltraNet Edge 3000 is for maintena...

Страница 353: ...the standard LC connector 1 Locate the I O interface configured as Fibre Channel 2 Locate the FC fiber cable with the standard LC connector 3 Align the cable connectors Receive Rx and Transmit Tx wit...

Страница 354: ...or long wave single mode transceivers see Appendix C Cables Connectors and Adapters for the specifications Instructions for removing and installing the transceivers are found in Chapter 12 Hardware Ma...

Страница 355: ...Rx and Tx Gently insert the connector Removing Gig E Cabling Use this section to remove the cabling from the Gig E interface 1 Grasp the LC connector at the end of the fiber optic cable 2 Depress the...

Страница 356: ...rs The OC 3 multi mode transceivers are white and the single mode are blue see Appendix C Cables Connectors and Adapters for the OC 3 ATM specifications Instructions for removing and installing the tr...

Страница 357: ...window display on front of the unit See the Indicators Switches and Interfaces section in Chapter 2 for descriptions of the indicators and alphanumeric displays or the LED Diagnostic Codes section in...

Страница 358: ...ctly to a PC For all RS 232 serial connections use RS 232 cables with RJ 45 connectors Connecting a Remote Modem to the UltraNet Edge 3000 Use the following procedure to connect a remote modem to the...

Страница 359: ...ce which is used for console connections This interface is set to communicate at 38 4K bps with eight data bits 1 stop bit no parity and no hardware flow control Table B 2 provides the pinouts for the...

Страница 360: ...cific AA adapter This cable adapter is provided with the UltraNet Edge 3000 and the optional remote support kit It inserts into the DCE port on the back of the remote modem for direct connection to th...

Страница 361: ...with proper grounding connections See Figure B 7 for the location of the wrist strap connectors Figure B 7 ESD Grounding Connection for UltraNet Edge 3000 Table B 4 Customer Supplied Cables and Equip...

Страница 362: ...re directly into the UltraNet Edge 3000 after removing it from the antistatic wrapping Do not remove the anti static wrapping until you are ready to do the install If you must set down an unwrapped sp...

Страница 363: ...M interfaces RS 232 Cables with RJ 45 Connector The RS 232 cable with RJ 45 connector is used to connect the UltraNet Edge 3000 to a serial interface Refer to Table C 1 for the lengths of the RS 232 c...

Страница 364: ...the AA adapter The AA is a DB25 to RJ45 RS 232 straight through adapter The AA adapter is attached to the remote modem for connection when directly attached to the UltraNet Edge 3000 Table C 2 DB Adap...

Страница 365: ...EE Adapter Pinouts RJ 45 Pin Out DB9 Pin Out EE Adapter 1 DTR 4 DTR 2 DSR 6 DSR 3 DCD 1 DCD 4 GND 5 GND 5 TXD 3 TXD 6 RXD 2 RXD 7 RTS 7 RTS 8 CTS 8 CTS Table C 5 provides the full names of the pinout...

Страница 366: ...to ANSI s Web site at http www ansi org Class 2 is a connectionless grade of service making use of mulitplexed frame switching with multiple sources sharing the same channels Class 2 supports confirm...

Страница 367: ...Gbps 62 5 microns 250 meters 1 0625 Gbps 62 5 microns 120 meters 2 125 Gbps Output Power 10 to 4 dBm Maximum Input Power 0 dBm Connector Type Duplex LC Single mode Reach 10 Km Core Diameter Cladding...

Страница 368: ...t Ethernet technology Table C 8 provides the Gigabit Ethernet cable type specifications Table C 7 Ethernet 10 100 Cable and Connector Specifications Cable Type Specification CAT5 UTP cable Line Rate C...

Страница 369: ...ational Wavelength 1310 nm Data Rate 1 25 Gbps Receiver sensitivity 21 dBm Transmitter output maximum power Transmitter output minimum power 3 dBm 9 5 dBm Output Power 5 dBm Maximum Input Power 14 5 d...

Страница 370: ...onnector Specifications Cable Type Specification Multi mode Short Reach Standard OC 3 SONET SDH STM 1 Fiber Cladding Diameter 62 5 125 and 50 125 micron Distance 50 micron 850 meters 62 5 micron 500 m...

Страница 371: ...smission Length 40 Km Operational wavelength 1310 nm Data Rate 155 Mbps Receiver Sensitivity 36 dBm Output Power 3 dBm Maximum Input Power 7 dBm Typical cable attenuation at 1300 nm 0 35to 0 50 dB Km...

Страница 372: ...C 10 UltraNet Edge Storage Router 3000 User Guide OC 3 ATM Specifications...

Страница 373: ...aming Settings Configuring the Internal McDATA Fibre Channel Switch Interface The following section pertains to F_port configurations and is only necessary to configure when using the UltraNet Edge 30...

Страница 374: ...ing the internal Fibre Channel Switch application with one port there are three tabs the Basic tab the Advanced tab and the FC Switch tab Basic Tab Select this tab to choose the I O Port I O Port Sele...

Страница 375: ...ort configurations Select this option to enable frame batching based on an MTU value The MTU batching size defines the MTU for the batch of backbone frames that are collected and transmitted as one pa...

Страница 376: ...layed if available If this information is not available N A is displayed Advanced Tab Configure the advanced FC Switch parameters from this tab Switch Priority Select the Switch Priority from the drop...

Страница 377: ...1 to 128 Seven is the default Zoning The Zoning drop down list displays all available values Select Port Zoning if your application requires device controller to device controller mapping or if you ha...

Страница 378: ...The UltraNet Edge 3000 TAI Temps Atomique International driver is responsible for time synchronization using the TAI time format The TAI driver is configured automatically through UCM to support the...

Страница 379: ...ppears 2 Double click the Time Server icon in the Logical View of the UltraNet Edge Expanded View screen The Time Synchronization Protocol screen appears 3 Select NTP Server and enter the NTP server a...

Страница 380: ...e circuit level before enabling the Transport CRC for all data feature This feature can be used for Data protection on a WAN that has known problems where the performance costs are tolerable Applicati...

Страница 381: ...l data passing through the circuit 5 Click OK E_Port Disk Streaming Settings The E_port Disk Streaming function is disabled by default When your network has been configured you can verify the settings...

Страница 382: ...treaming see Enable Disk Streaming in this chapter F_Port Disk Streaming Settings The F_port Disk Streaming function is disabled by default Once your network has been configured you can verify the set...

Страница 383: ...ble or disable Disk Streaming To disable F_port Disk Streaming clear the Enable Disk Streaming check box and click OK To enable F_port Disk Streaming select the Enable Disk Streaming check box and cli...

Страница 384: ...D 12 UltraNet Edge Storage Router 3000 User Guide F_Port Disk Streaming Settings...

Страница 385: ...appendix describes how to display verify add delete and modify static routes Display Static Routes Use the following procedure to display static routes 1 Double click on the IP link circuit 90 The IPC...

Страница 386: ...P configuration properties for each node on the circuit and the static routes for the nodes that connect to the circuit Verify Static Routes Use the following procedure to verify static routes 1 Click...

Страница 387: ...ault gateway fields are automatically updated when the Ethernet Maintenance interface is configured via the Initial Config step The host specific static route fields are updated when the IP circuit is...

Страница 388: ...lly updated when the IP circuit is configured Modify Static Routes To modify the existing entries highlight the data to be changed and replace it with the new data Add Static Routes If additional entr...

Страница 389: ...SNMP on the UltraNet Edge 3000 Configure SNMP on the UltraNet Edge 3000 Use the following procedure to configure SNMP if you are managing any UltraNet Edge 3000 using a network management tool 1 At th...

Страница 390: ...F 2 UltraNet Edge Storage Router 3000 User Guide 2 The UltraNet Edge 3000 Expanded View Node 10 screen appears 3 Select the SNMP tab...

Страница 391: ...upper and lower case letters you must enter at least one character a Enter the type or description of the node in the Description field b Enter the contact information in the Contact field c Check the...

Страница 392: ...onfigured SNMP trap destinations b Set the Default Action field to either Allow or Deny see Table F 1 for an explanation of this field c Set the Read Community field to public d Set the Write Communit...

Страница 393: ...he configurations files NOTE For more detailed information see the UltraNet ConfigManager online Help Table F 1 SNMP Configuration Screen Fields Field Description Authentication Traps Yes enables the...

Страница 394: ...Edge 3000 SNMP agent forwards traps to defined trap destinations based on severity levels The severity levels in the UltraNet Edge 3000 range from 0 7 The lower the number the more critical the messa...

Страница 395: ...A has verified that the following SNMP software packages will compile the MIBs correctly SimpleSoft SimpleTester v8 0 0 Castle Rock Computing Version 5 0 4d Epilogue Technology Emissary SNMP MIB Compi...

Страница 396: ...F 8 UltraNet Edge Storage Router 3000 User Guide SNMP Software Packages...

Страница 397: ...ion Use this command with caution Once the sysclean command is complete the Edge will issue bootp requests for initial IP configuration Using the Sysclean Command Use the following procedure to restor...

Страница 398: ...e proprietary and confidential property of CNT Any Disclosure use or reproduction without the prior written consent of CNT is strictly prohibited Failure to properly protect this material could subjec...

Страница 399: ...MHz Board Edge HwRev 0 Map A Memory Size 0x4000000 dsk Volume is OK Loading system DLLs ld 0 0 dsk vx core dll Loaded CNTCORE build 358 value 28191040 0x1ae2940 ld 0 0 dsk vx httpd dll Starting HTTP s...

Страница 400: ...tive SYSTEM CFG SYSTEMPR deleting file dsk cnt configs active SYSTEM CFG SNMP deleting file dsk cnt configs active SYSTEM CFG IPROUTEG deleting file dsk cnt configs active SYSTEM CFG DLMRULES value 0...

Страница 401: ...en done Manually Configure the Maintenance IP Port using the Command Line Interface Before you begin You need the Maintenance Port IP address default gateway address and subnet mask to complete this p...

Страница 402: ...gure these parameters are shown in Fields A B F and G Quotation marks and commas must be used when using this command 14 At the prom prompt type reset The UltraNet Edge 3000 will reboot and bring you...

Страница 403: ...e Manual Configurations It is necessary to update the UltraNet ConfigManager application with the configuration information you entered manually After using UltraNet ConfigManager to configure the ent...

Страница 404: ...t Gateway for the Maintenance Port IP 5 Click inside the Gateway field and enter the Gateway address for the Maintenance Port IP 6 Change the Precedence field from Preferred to Default The first entry...

Страница 405: ...d not configure the Maintenance Port IP using the Set Initial Config option 8 Click Yes in the Warning message to update the Maintenance Port IP address to the UltraNet ConfigManager application 9 Fol...

Страница 406: ...H 6 UltraNet Edge Storage Router 3000 User Guide Update UltraNet ConfigManager with the Manual Configurations...

Страница 407: ...3000 to recover faster Issuing the Spantree Portfast Command Issue the spantree portfast command only when faster recovery for the UltraNet Edge 3000 is necessary NOTE The information contained in the...

Страница 408: ...st start feature on a port 2 of module 1 Console enable set spantree portfast 1 2 enable Warning Spantree port fast start should only be enabled on ports connected to a single host Connecting hubs con...

Страница 409: ...for ATM WAN network configurations The worksheets may be copied and used to record information on hardcopy or they may be used as a guideline for creating a worksheet in a file format that may be easi...

Страница 410: ...Router 3000 User Guide Configuration Worksheets IP Configuration Worksheet Complete both rows labeled 1x1 and 2x2 if you are configuring a 2x2 See Figure for an example along with the relationship to...

Страница 411: ...J 3 Configuration Worksheets Figure J 1 Sample IP Worksheet and Relationship to Hardware Configuration...

Страница 412: ...ter 3000 User Guide Configuration Worksheets ATM WAN Configuration Worrksheet Complete both rows labeled 1x1 and 2x2 if you are configuring a 2x2 See Figure for an example along with the relationship...

Страница 413: ...J 5 Configuration Worksheets Figure J 2 Sample ATM WAN Worksheet and Relationship to Hardware Configuration...

Страница 414: ...J 6 UltraNet Edge Storage Router 3000 User Guide Configuration Worksheets...

Страница 415: ...nd transmits these messages to every member of an emulated LAN BUS See Broadcast and Unknown Server bus number A bus number is assigned to every physical trunk or link that connects two UltraNet Edge...

Страница 416: ...c One or more Fibre Channel switches in a networked topology fault tolerant By using a method of remote mirroring the UltraNet Edge 3000 system ensures that even in the event of a power failure a disk...

Страница 417: ...design is set hardwired chips are produced for faster performance gateway A device that allows communication between dissimilar protocols by translating information from one protocol to another GBIC...

Страница 418: ...nd retrieval isochronous Signals that are dependent on some uniform timing or carry their own timing information embedded as part of the signal LAN See Local Area Network Local Area Network A geograph...

Страница 419: ...ds that portion of the routing table keeps track of routes to particular network destinations that describes the state of its own links and it also sends the complete routing structure topography The...

Страница 420: ...Network Management Protocol A common method by which network management applications can query a management agent using a support MIB SNMP operates at the OSI Application layer Small Form Factor Plugg...

Страница 421: ...us Signals that are sourced from the same timing reference and have the same frequency FC SCSI Tape Pipelining Performs remote tape backup performance over extended distances using a new or existing I...

Страница 422: ...g 8 Glossary Zoning A feature in Fabric switches or hubs that allow segmentation of a node by physical port name or address...

Страница 423: ...n 30200518 Spantree Portfast for Cisco routers I 1 sysclean G 1 user interface for troubleshooting 13 1 components hardware 2 11 compression diagnostic program 13 27 configuration features 1 6 config...

Страница 424: ...d to end CRC 3 13 environmental specifications A 3 air flow A 3 electromagnetic emissions A 3 electromagnetic immunity A 3 heat generated A 3 operation environment A 3 safety A 3 ESD electrostatic dis...

Страница 425: ...n procedures fan assembly 12 4 power supply 12 7 UltraNet Edge Storage Router B 1 interfaces 2 13 internal switch FCSW 6 1 IP load balancing 1 3 J Java plug in 11 12 L LAN local area network 1 1 LEDs...

Страница 426: ...cable part numbers and length C 1 routing options 3 8 RS 232 cables B 14 pinouts B 13 S safety specifications A 3 security default password Edge 1 7 WebView 11 12 serial interface connection 13 17 ser...

Страница 427: ...net B 9 multi mode Fibre Channel 1 4 B 7 C 4 multi mode Gig E 1 5 B 8 B 9 C 6 multi mode OC 3 1 6 B 10 C 8 single mode Fibre Channel 1 4 single mode Gig E 1 5 B 8 B 9 C 7 single mode OC 3 1 6 B 10 C 8...

Страница 428: ...UltraNet Edge Storage Router 3000 User Guide i 6 Index...

Отзывы: