![McCrometer ML255 Скачать руководство пользователя страница 24](http://html.mh-extra.com/html/mccrometer/ml255/ml255_installation-operation-and-maintenance-manual_1753761024.webp)
CONVERTER START-UP - ALL SENSORS
Copyright © 2018 McCrometer, Inc. All printed material should not be changed or altered without permission of McCrometer.
Any published technical data and instructions are subject to change without notice. Contact your McCrometer representative
for current technical data and instructions.
www.mccrometer.com
3255 WEST STETSON AVENUE • HEMET, CALIFORNIA 92545 USA
Printed In The U.S.A.
TEL: 951-652-6811 • 800-220-2279 • FAX: 951-652-3078
Lit. # 30122-46 Rev. 1.2 / 5-31-18
22
6.3
Factory Set Key Code
The converter is delivered with key code L2 =
000002
, and with the “Quick start menu” enabled. Press the Enter/
Esc key. The “Quick start menu” is enabled from the section: Menu “8-Display”, section 10.8.
i
ATTENTION
!
It is very important to record any customized code as it CANNOT be retrieved if it is lost! The converter will
need to be returned to be reset to factory settings.
6.4
Menu Structure
The following is the menu structure for the converter.
NOTE:
Some menus change as options are enabled.
2.1* Full scale value measure set for flowrate
2.2* Pulse value on channel 1
2.3* Duration of the pulse generated on channel 1
2.5* Duration of the pulse generated on channel 2
2.6 Full scale value set for pressure measure
2.8* Unit of measure and number of decimal totalizes
2.7 Unit of measure of temperature
2.4* Pulse value on channel 2
3.1 Low flow zero threshold: 0-25% of full scale value
3.2* Consumption profiles
4.1 Maximum value alarm set for direct flow rate
4.2 Minimum value alarm set for direct flow rate
4.3 Maximum value alarm set for reverse flow rate
4.5 Maximum value alarm set for pressure 1
4.6 Minimum value alarm set for pressure 1
4.4 Minimum value alarm set for reverse flow rate
4.7 Maximum value alarm set for pressure 2
4.6 Minimum value alarm set for pressure 2
4.7 Maximum value alarm set for differential pressure
4.8 Minimum value alarm set for differential pressure
4.9 Hysteresis threshold set for the minimum and maximum flow rate alarms
5.1* Total direct (positive) flow totalise reset enable
5.2* Partial direct (positive) flow totalise reset enable
5.3* Total reverse (negative) flow totalise reset enable
5.6 Totalise counting lock command
5.7* Autozero calibration external command
5.4* Partial reverse (negative) flow totalise reset enable
5.8 Alarm from external signal (i.e. flooding/intrusion/..)
5.8* Auto- switch on command
6.1* Output 1
6.6 Power supply of pressure probes
6.5* Output 2
1.1 Insert ND of sensor (0-3000)
1.2 Calibration data of sensor visualized on sensor's label
1.3 Sensors model: Enter the first two characters of the serial number of the sensor
1.4 Position for insertion sensors: 0=1/8DN, 1=1/2DN, 2=7/8DN
1.5 Factory parameter
1.6 Automatic setting according to ID ( insertion meter only )
1.7 Automatic setting according to ID ( insertion meter only )
1.8 Enables the empty pipe detection function
1.9 Value of empty pipe sensibility detection
1.10 Perfom a SENSOR TEST ( sensor MUST be connected)
1.11*Enables the automatic zero calibration system
1.12 Reset the preceding value
* (Communication function group only) = see wireless specific
specific manual supplied for more details
7.1 Choice of the communication protocol for the IF2 device
7.2 Minimum antenna signal strength to send e-mail*
7.3 Choice of how to send data logger*
7.5 Interval of data logger sending if 7.4 is set on "PERIODIC"
7.6 Interval of sending DATA LOGGER*
7.4 Choice of when send data logger*
7.7 Send Process data*
7.8 Send Alarm*
7.11 Send EVENTS , instant command*
7.9 Roaming enable*
7.10 Send Data Logger , instant command*
7.12 Send config through e-mail immediately*
7.13 Enables clock synchronization with a specified server via the HTTP protocol*
7.14 Check INCOMING E-MAIL*
7.8 Check INCOMING SMS*
8.1 Choice of the language: EN= English, IT=Italian, FR= French, SP= Spanish
8.2 Time for switch off display (shown with function 3.7 enabled)
8.3 Visualization of "Quick start menu"
8.5* Total direct (positive) flow totalizer reset from keyboard
8.6* Partial direct (positive) flow totalizer reset from keyboard
8.4 lock of DISPLAY in ONE SPECIFIC visualization page
8.7* Total reverse (negative) flow totalizer reset enable from keyboard
8.8* Partial reverse (negative) flow totalizer reset enable from keyboard
11.1 Level 2 access code enter
11.2 Load factory data pre-set
11.3 Ks Coefficient
9.1* Date and time set
9.2 Set of Time Zone ( Against GMT -12 to +12 hours)
9.3* Automatic data logger enable
9.5* choice of single (off) or double (on) interface
9.6* Interval time 1 for the data logging function
9.4 Data formatted like ML250
9.7* Interval time 2 for the data logging function
9.10 Enables the sending of direct total totalizer
9.11 Enables the sending of direct partial totalizer
9.12 Enables the sending of reverse total totalizer
9.13 Enables the sending of reverse partial totalizer
9.14 Enables the sending of net total totalizer
9.15 Enables the sending of net partial totalizer
9.16 Enables the sending of flow rate
9.17 Enables the sending of pressure 1
9.18 Enables the sending of pressure 2
9.19 Enables the sending of differential pressure
9.18 Enables the sending of temperature
9.20*Loggin of statistical data
9.21 Enables the sending of measure units ( technical units )
9.22 Enables the sending of measure units ( % )
9.23 Symbol used as separator on CSV files
9.8 Interval 2 start loggin time
9.9 Interval 2 stop loggin time
10.1 Perfrom a sensor test (SENSOR MUST BE CONNECTED)
10.2* Converter auto-test
10.4* Stand-by function
10.5* Test of GPRS connections
10.3* Flow rate simulation enabling
10.6* SD card status/info
Note : all references to page number are linked to the operating manual .
!2.UGPUQT!
PF>oo!
11467
MB>!
,13/1111
Kpu/rqukvkqp>!
1
Mk>!
2/1111
Mr>!
2/1111
M\>!
,111111
ME>!
2/1111
VE2>ou!
121
VE3>ou!
112
G/R/fgvgev>!
QP
G/r/vjt>!
181
\gtq!ecn/
\gtq!tgu/
PF>oo!
11467
!3.UEBNGU!
Hu>Icn0o!
3611/1
Vgor/w/ogcu/>! úH
Vqv2OW>MIN! 11112
Rnu2>MIN! 2/11111
Vrnu2>ou!
1161/1
!4.OGBUWTG
Ewv.qhh>&!
14/1
Rtqh!>!
OBZ!NKHG
Fcorkpi>!
QHH
!5.BNBTOU
Bn/ocz,>&!
111
Bn/okp,>&!
111
Bn/ocz.>&!
111
Bn/okp.>&!
111
J{uv/>&!
14
!6.KPRWVU
V,!tgugv>!
QP
V.!tgugv>!
QP
Eqwpv!nqem>!
QHH
Bncto>!
QHH
Ycmg.wr>!
QHH
!7.QWVRWVU
Qwv2>!
RNU,
Qwv3>!
QHH
!8.EQOOWPKEBVKQP
KH3!rtqv/>!
FRR
!9.FKURNB[
Ncpiwcig!
GP
F/vkog>u!
171
Swkem!uvctv>!
QP
Fkur/nqem>!
QHH
V,!tgugv
V.!tgugv
!9.FKURNB[
Ncpiwcig!
GP
F/vkog>u!
171
Swkem!uvctv>!
QP
Fkur/nqem>!
QHH
V,!tgugv
V.!tgugv
!9.FKURNB[
Ncpiwcig!
GP
F/vkog>u!
171
Swkem!uvctv>!
QP
Fkur/nqem>!
QHH
GZGEWVG@
V.!tgugv
!9.FKURNB[
Ncpiwcig!
GP
F/vkog>u!
171
Swkem!uvctv>!
QP
Fkur/nqem>!
QHH
!!!!!!!!!!!!!FQPG
V.!tgugv
!:.FBVB!NQIIGT
3127018031!!18;42
V/|qpg>j!
.19/1
Beswkukvkqp>!
QP
Eqor/oqfg>!
QP
kpv/2!>!24j11o11u
Nqi!V,>!
QP
Nqi!R,>!
QP
Nqv!V.>!
QP
Nqi!R.>!
QP
Nqi!PV>!
QP
Nqi!PR>!
QP
Nqi!S>!
QP
Nqi!UVBV>!
QP
O/wpkvu>!
QP
&!xcnwgu>!
QHH
!21.FKBIPQUVKE!
Ugnh!vguv
Ukowncvkqp>!
QHH
Fkurnc{!fcvc
Uvcpf.d{
Tgcf!UFE!kphq
Hktoyctg!tgx/
!22.KPVGTPBN!FBVB
N3!eqfg>!
++++++
Nqcf!hcev/fcvc
U0p>!
182341
MV>!
,2/1111
MT>!
,2/1111
MU>!
,2/1111