Installation of stove into the system for water heating
- For water inlet and outlet within the system of floor (central) heating are provided
with adapters on boiler 1".
- Thermo IN may be installed on closed or open system of central heating.
Installation on closed central heating system
One of the aspects of mounting installations is depicted on figure 5.
- Safety valve must be installed in the vicinity of boiler and must be adjusted for
pressure of max. 3 bars. External guide of safety valve must be as shorter as
possible and may not have possibility to be closed. Within this guide, also, there may
not be single valve or any other armature.
- Closed expansion vessel is to be installed in the vicinity of boiler and its safety
guide is short. Volume of this vessel is determined according to the capacity of boiler
and regarding ratio 1kW:1l.
- Installation of thermal valve in its provided place on the boiler is mandatory. We
recommend thermal valve Caleffi 544.