MANAGING STOVE OPERATION
Pace of combustion, as well as quantity of heat transmitted by the stove, depends
on the quantity of primary air for combustion which is brought into the area below
firebox. Regulation of quantity of primary air is provided automatically using thermo-
regulator
Rathgeber
(figure 7).
Figure 7
Upon ignition, turn regulator button into position of maximally opened flap in
direction displayed on figure 8. During operation, depending on temperature,
regulator flap will open and close automatically. If lower temperature then adjusted is
desired, turn regulator button in desired position of minimally open flap, thus
regulator flap closes. Button is to be turned with auxiliary tool while longer side of the
tool is to be put into the rifle of button by turning, as desired. (Fig. 8.)
Figure 8
If there are disturbances in burning (weak fuel, remaining malfunctions for proper
operation of stove) then through auxiliary regulator, which is located on front side of
the ashtray door (figure 1 position 11), we can bring some additional primary air, thus
improving combustion.