d) Locate
the
Blue wire
,
Pin #1
(across from
Green / Red-striped wire in pin #12).
(Fig. 5-19)
e) Attach wire tap connector to
Blue Wire
approximately ½” down from connector.
(Fig. 5-20)
f)
Using pliers, close 2 sides of wire-tap onto wire.
3. Connect EC Power harness to +12V ignition.
b) Insert male spade terminal
of Black / White-
striped wire
into opening of wire tap on the
Blue wire
.
(Fig. 5-21)
4. Attach wire tap connector to B+ Constant in upper
20-pin A-pillar connector.
a) Locate the
Yellow / Green-striped
wire
in
pin
#4
, of the 14-pin upper connector.
(Fig. 5-22)
Fig. 5-20
Upper
Connector
Blue
Pin #1
Lower
Connector
Fig. 5-21
Fig. 5-19
C214
+12V IGN
B+
C214
Fig. 5-22
NOTE
!
Ensure correct wire (pin location 1) is identified.
Ensure male spade connector is fully inserted into wire tap.
Check to see that the spade connector did not miss the slot.
Check to see that it is not visible on either side of the female
connector.
CAUTION
!
NOTE
!
Ensure correct wire (pin location 4) is identified.
Page 11 of 17
9/1/2010