Disassembly Procedures
To avoid the risk of electrical shock, personal injury or
death, disconnect power to oven and discharge
capacitors before following any disassembly procedure.
WARNING
!
20
16023053 Rev. 0
©2004 Maytag Appliances Company
High voltage is present at the high voltage terminal of the
high voltage transformer during any cooking cycle.
It is neither necessary or advisable to attempt
measurement of the high voltage.
Before touching any oven components or wiring, always
unplug the oven from its power source and discharge
capacitor.
Disconnecting Wire Terminals
All wire terminals are locking-type terminals.
Proceed as follows to disconnect wire terminals:
Insulated terminals:
Grasp insulator pod and pull back.
DO NOT PULL ON WIRE.
1 Grasp
Wire
Insulator
Pod
2 Pull
Non-insulated terminals:
Use a small blade screwdriver to depress locking-tab
and pull on terminal.
DO NOT PULL ON WIRE.
1 Release
locking-tab
Wire
2 Pull
Outer Case
1. Disconnect power to oven.
2. Remove screws securing outer case to unit.
3. Slide outer case towards rear of unit.
4. Reassemble in reverse order.
Door Assembly
CAUTION
!
A microwave leakage test must be performed anytime
a door assembly is removed, replaced, disassembled,
or adjusted for any reason.
Door Removal
1. Disconnect power to oven.
2. Open oven door, remove top hinge cap, and slowly
lift door to disengage the hinge pins at top and
bottom.
Top hinge cap
3. To re-install door, place bottom pin into slot first, then
align top pin.
4. Replace top hinge cap.