12
16023053 Rev. 0
©2004 Maytag Appliances Company
Trouble 1: The following visual conditions indicate a probable failed control circuit.
1. Incomplete segments.
• Segment missing.
• Partial segment missing.
• Digit flickering (Note: Slight flickering is normal.)
2. Colon does not turn on or blink.
3. A distinct change in the brightness of one or more numbers in display.
4. One or more digits in the display are not lighting.
5. Display indicates a number different from one touched, for example, key in 5 and 3 appears in the display.
6. Specific numbers (for example 7 or 9) will not display when key pad is touched.
7. Display does not count down with time blinking or count up during operation.
8. Display obviously jumps in time while counting down.
9. Display counts down too fast while cooking.
10. Each indicator light does not turn on after setting cooking cycle.
11. Display time of day does not reappear when cooking is finshed.
Condition
Check
Result
Cause
Remedy
No input can be
programmed.
Check the connection
between keypad and
controller.
•
Continuity
•
Failed
controller.
•
Replace
controller.
•
No continuity
•
Loose
connection.
•
Repair
connection.
1. Some
inputs
cannot be
programmed.
Replace keypad and check
operation.
•
Everything
works as
specified.
•
Failed
keypad.
•
Replace
keypad.
2. Display
shows
a number or
figure different
from one
touched.
•
Still have
trouble.
•
Failed
controller.
•
Replace
controller.
3. Random
programming
when touching
other pads.
4. Display
is
fixed
at some figure
and can not
accept any
input.
Troubleshooting Procedures (Electronic Models)