background image

©2002 Maytag Appliances Company

16021520   Rev. 0

A–13

Operation

START

STOP

RESET

8

P:02

MICRO  DEFR  WARM  MEDHI  POWER  HOLD

1

COOK
LEVEL

TIMER

READY

CLOCK

0P:--

MICRO  DEFR  WARM  MEDHI  POWER  HOLD

8

COOK
LEVEL

TIMER

READY

CLOCK

8

P:0

8

MICRO  DEFR  WARM  MEDHI  POWER  HOLD

8

COOK
LEVEL

TIMER

READY

CLOCK

Programming Displays

This display indicates
oven is in programming
mode and ready to
program a numbered
pad(s).

This display shows briefly
when programming more
than one stage. It
indicates programming

mode for pad 02. The smaller “1” indicates stage 1 is
being programmed.

This display indicates
programming user
options mode. See “User
Options” section of
manual for programming
procedure.

Interrupting Operation

Open oven door or press 

STOP/RESET

 pad

to interrupt operation. Display continues to
show countdown time. Close door and press

START

 pad to resume oven operation.

Preprogrammed Times and Cook Level

All preprogrammed pads arrive set at full power.

Cooking Methods

Single Pad Cooking

From the factory, oven is programmed to
store 10 cooking programs. Each pad
begins a cooking program.

Manual Time Entry

Manual Time Entry feature allows the
operator to heat foods without changing the
preprogrammed pads. Time must be entered
and power level can be set before cooking.
START pad must be pressed to begin
cooking.

Cooking Displays

READY shows when oven
control will accept entries.

25:20

 shows cooking

time. When more than
one cooking stage is
programmed, total time

for all stages displays.

  

POWER shows when microwave

energy is generated. Display will show DEFR, MED, and
MED HI to indicate microwave power level used. If no
display is shown, oven is cooking at 100% power.

88:88

MICRO  DEFR  WARM  MEDHI  POWER  HOLD

8

COOK
LEVEL

TIMER

READY

CLOCK

25:20

MICRO  DEFR    MED    

MEDHI

 

 POWER  

HOLD

8

COOK
LEVEL

TIMER

READY

CLOCK

1

TIME

ENTRY

MEDIUM

50%

START

RFS10SW2

Pads

Times

Pads

Times

1

25 sec.

6

1 min.

2

35 sec.

7

2 min.

3

45 sec.

8

0

4

1:45 min.

9

5 min.

5

40 sec.

0

8 min.

RFS12SW2

Pads

Times

Pads

Times

1

20 sec.

6

55 sec.

2

30 sec.

7

1:25 min.

3

35 sec.

8

0

4

1:25 min.

9

4 min.

5

35 sec.

0

6:15 min.

Содержание 1324704M

Страница 1: ...e procedures done by an unqualified person 16021520 Revision 0 October 2002 This manual replace RS2240001 Revision 2 RCS10 P1140411M RCS10 P1324601M RCS10 P1327703M RCS10D P1152809M RCS10D P1327701M R...

Страница 2: ...ING REPAIRS WARNING To avoid risk of severe personal injury or death disconnect power before working servicing on appliance to avoid electrical shock To locate an authorized servicer please consult yo...

Страница 3: ...r Holaday HI1501 HI1510 and HI1710 18 Troubleshooting Guide 19 Table of Contents Disassembly Procedures Outer Case Removal 21 Start Switch and Button 21 Control Assembly painted models 21 Control Asse...

Страница 4: ......

Страница 5: ...ructions is 4mw cm2 14 If servicer encounters an emission reading over 4mw cm2 the servicer is to cease repair and contact the Amana Service Department immediately for further direction Amana Manufact...

Страница 6: ...ONLY by qualified service personnel Special tools are required to service equipment Contact nearest authorized service facility for examination repair or adjustment 10 DO NOT cover or block filter or...

Страница 7: ...rials that are not intended for cooking 11 When cooking with paper plastic or other combustible materials follow manufacturer s recommendations on product use 12 Do not use paper towels which contain...

Страница 8: ...uctions WARNING Do not remove grounding prong when installing grounded appliance in a home or business that does not have three wire grounding receptacle under no condition is grounding prong to be cu...

Страница 9: ...is the smaller size and should always be hot live with respect to neutral N and ground G Ground G The round hole connection is for the grounding circuit Behind the cover plate a green wire should be...

Страница 10: ...ertop surface A A A A Allow at least 1 inches 3 81 centimeters of clearance around top and sides of equipment Proper air flow around equipment cools electrical components With restricted air flow oven...

Страница 11: ...Air product call 1 800 462 9824 or visit the Web Site at www maytag com or www jennair com For product inCanada call 1 866 587 2002 or visit the Web Sites at www amana com or www maytag com or www jen...

Страница 12: ...nal to Case Infinite resistance Magnetron Discharge Capacitor Remove wires from magnetron and connect ohmmeter to terminals Also check between each terminal and ground Between Terminals Less than 1 Ea...

Страница 13: ...ndition 0 volts Idle condition Line voltage Cook condition 1 1 VAC Idle condition 0 volts A B C J E Pin 1 P2 P1 Internal Display Graphics Pin 1 P3 F K H HV LV board RFS10SW2 RFS12SW2 RFS12MPS RFS12S A...

Страница 14: ...0 4 10 5 7 6 7 Measurement Continuity Continuity Continuity Continuity Continuity Continuity Continuity Continuity Continuity Continuity Continuity Continuity Continuity Continuity Continuity Continui...

Страница 15: ...TES The IEC 705 test method requires precision measurements and equipment It is not practical to perform the IEC test in the field To convert the traditional power test results to the approximate IEC...

Страница 16: ...ry current if high voltage is applied R F Capacitors May short to chassis This condition will also cause loss of high voltage 2 Open Heater Filament Can be determined by a ohmmeter when transformer le...

Страница 17: ...fully assembly oven before the latch switch primary is interrupted while pulling the door 4 mW cm2 or less 1 Pour 275 cc 15 cc 9 oz 1 2 oz of 20 C 5 C 68 F 9 F water in a beaker which is graduated to...

Страница 18: ...m setting plug in AC cord If probe test fails do not use probe During usage if probe becomes inoperative or disconnected audio alarm will come on Test probe must be held by the grip portion of the han...

Страница 19: ...grip portion of the handle otherwise a false reading may result if operators hand is between the handle and probe If oven is likely to have a large amount of leakage approach oven slowly with the prob...

Страница 20: ...for overload circuit 2 Voltage available to outlet No components operating including oven light Open power cord Failed terminal and or wiring Open line fuse See Condition 3 Open cavity thermal fuse Op...

Страница 21: ...ate unit cooks slowly all modes 1 Run Oven Performance Tests if okay customer education 2 Check voltage at outlet if low customer education 3 Check amperes and or wattage compare to Specification Shee...

Страница 22: ...rotate thinplate counterclockwise to gain access to start button and to the screws securing start switch assembly 6 Reverse procedures to reassemble Control Assembly painted models 1 Disconnect power...

Страница 23: ...utton 3 Drill out rivet Amana part number A4539625 to remove the foot Blower Motor or Wheel NOTE Blower wheel has a D type hole in hub and clip on end of motor shaft 1 Disconnect power to oven 2 Remov...

Страница 24: ...ight 1 Remove outer case 2 Remove TCO by removing screws 3 Disconnect wiring Cavity Thermal Fuse 1 Remove outer case 2 Remove thermal fuse mounting screw 3 Disconnect wiring Door Disassembly Door Asse...

Страница 25: ...needs curing Unit should not be used for minimum of one hour after application Follow all precautionary information shown on manufacturer s container 1 Unplug oven from outlet 2 Using a thin bladed k...

Страница 26: ...A 7 RCS10 P1324601M A 7 RCS10 P1327703M A 7 RCS10MP P1324602M A 7 RCS10MP P1327704M A 7 RCS10MPS P1324902M A 7 RCS10MPS P1327705M A 7 RFS10S P1324701M A 7 RFS10S P1327708M A 7 RFS12MPS P1324704M A 7...

Страница 27: ...Pads 1 Open oven door place food in oven and close oven door 2 Press desired number pad 3 Oven stops heating and oven signal sounds when heating timing elapses Preprogrammed Number Pads 1 Open oven d...

Страница 28: ...ven can heat at full or reduced power If oven power level is set to 0 oven does not heat for programmed time If no power level is selected oven operates at 100 power START Use to start Manual Time Ent...

Страница 29: ...Press desired number pad 4 Press number pads to enter desired cooking time 5 Press a power level pad if power level less than 100 percent is required 6 Press TIME ENTRY pad 7 Press START pad to save n...

Страница 30: ...ignals at end of heating cycle 3 OP 30 Allows 99 minutes 99 seconds of heating time OP 31 Allows 10 minutes of heating time 4 OP 40 Prevents signal when pad is pressed OP 41 Allows signal when pad is...

Страница 31: ...al Metallic trimmed china Utensil Check Test Use the following test to check utensils for microwave safeness 1 Place glass measuring cup of water next to empty dish to be tested in microwave oven 2 He...

Страница 32: ...START X2 88 88 M I C R OD E F R W A R M M E D H IP O W E R HOLD TIMER READY CLOCK COOK LEVEL 8 RCS10MPS and RFS12MPS Only RCS10 RFS9B RFS10S and RFS12S Control Panel Features Features 1 6 7 8 0 HOLD...

Страница 33: ...old at 0 power the third to heat at 50 power and the fourth to heat at 100 power Total time for all cooking stages counts down User Options User Options allow the user to program the oven to perform i...

Страница 34: ...ered pad s This display indicates oven is set to double pad entry and 2 pads must be pressed to enter a program See Programming section of manual for programming procedure or User Options to change fr...

Страница 35: ...Time Not Available on RCS10 OP 70 OP 71 Allows 60 minutes of heating time Allows 10 minutes of heating time 8 Manual Operation OP 80 OP 81 Allows use of preprogrammed pads only Allows use of manual ti...

Страница 36: ...desired power level 7 Press START pad to save new cooking time and power level in oven memory 8 Press STOP RESET pad or close oven door to exit programming mode Programming Multiple Cooking Stages 1...

Страница 37: ...are used to set microwave power level When cooking the power level can be decreased for foods that require slower more even cooking If cooking time is set and START pad pressed oven cooks at 100 power...

Страница 38: ...full power Cooking Methods Single Pad Cooking From the factory oven is programmed to store 10 cooking programs Each pad begins a cooking program Manual Time Entry Manual Time Entry feature allows the...

Страница 39: ...hen door is opened during cycle 7 Maximum Heating Time OP 70 OP 71 Allows 60 minutes of heating time Allows 10 minutes of heating time 8 Manual Operation OP 80 OP 81 Allows use of preprogrammed pads o...

Страница 40: ...2002 Maytag Appliances Company 16021520 Rev 0 B 1 Appendix B...

Страница 41: ...en 2 Remove screw from back of oven and remove access cover See illustration below 3 Remove bulb by turning counterclockwise being careful not to burn fingers or break bulb Replace with appliance bulb...

Страница 42: ...Filter RFS models only CAUTION To avoid overheating and oven damage clean air filter regularly To avoid oven door damage do not lift oven by oven door Filter is located below oven control panel Clean...

Отзывы: