Component Specifications
!
WARNING
To avoid risk of electrical shock, personal injury or death; disconnect power to oven and discharge capacitor
before servicing, unless testing requires power.
©2002 Maytag Appliances Company
16021520 Rev. 0
13
Illustration
Component
Testing
Results
NO
NC
COM
Start switch
Switch connection in following
positions:
Engaged
−
(Push in and hold)
Disengaged
−
(Normal
position)
COM-NO=Closed
COM-NO=Open
Relay
Refer to wiring diagram for
terminal identification.
AROMAT
O
Terminals
Te
Coil-115 VAC
5 & 6
Contacts # 1
3 & 4
Contact # 2
1 & 2
12
3
4
5
6
AROMAT
0
1
2
4
6
8
OMRON
Keyboard assembly
RCS10
P1140411M
RCS10MP
P1140412M
RCS10MPS
P1324901M
RFS9B
P1324706M
P1327707M
Continuity is indicated as 100
Ω
and below.
1
2
3
4
5
6
7
8
9
10
11
The following are Hidden
Keypads:
ENABLE
SECONDS
HOLD/MIN
Pad
DEFROST
MEDIUM
MED-HIGH
TIME ENTRY
RESET
START
ENABLE
SECONDS
HOLD/MIN
1
2
3
4
5
6
7
8
9
0
Trace
3 & 4
3 & 5
3 & 6
3 & 7
3 & 8
3 & 9
5 & 9
6 & 9
8 & 9
7 & 8
7 & 9
5 & 8
6 & 10
7 & 10
5 & 10
8 & 10
4 & 10
5 & 7
6 & 7
Measurement
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Keyboard assembly
RCS10
P1324601M
P1327703M
RCS10MP
P1324602M
P1327704M
RCS10MPS
P1324902M
P1327705M
RCS10MPSED P1324906M
P1327706M
RFS10S
P1324701M
P1327708M
RFS10SW2
P1324702M
P1327709M
RFS12MPS
P1324704M
P1327711M
RFS12S
P1324703M
P1327710M
RFS12SW2
P1324705M
P1327712M
Continuity is indicated as 100
Ω
and below.
1
2
3
4
5
6
7
8
9
10
11
Pad
DEFROST
MEDIUM
MED-HIGH
TIME ENTRY
STOP/RESET
START
HOLD
X 2
1
2
3
4
5
6
7
8
9
0
Trace
6 & 7
5 & 7
4 & 7
7 & 8
4 & 8
4 & 9
3 & 8
6 & 8
8 & 10
7 & 10
6 & 10
5 & 10
4 & 10
3 & 10
8 & 9
7 & 9
6 & 9
5 & 9
Measurement
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Lamp receptacle
Test continuity of receptacle
terminals.
Indicates continuity with bulb installed.
Lamp 41 W
Measure resistance of
filament.
Approximately 28
Ω
Wire Harness
Test continuity of wires
Indicates continuity