121022 v1.02-RiA
Operating instructions SG-RS 309-2
Page 7/23
Parts supplied
Terminals:
Connections:
A1, A2
Supply voltage
Sensor input
Y1, Y2
Sensor 1
Y3, Y4
Sensor 2
Reset
S13, S15
Bridge for automatic reset
S14, S15
Bridge for automatic reset
S13, S14
Manual reset button
S14
Controlled reset input
Monitoring circuit 1 (sensor 1)
12
Semiconductor output OSSD 1.1
32
Semiconductor output OSSD 1.2
M1
Signal output
Monitoring circuit 2 (sensor 2)
22
Semiconductor output OSSD 2.1
42
Semiconductor output OSSD 2.2
M2
Signal output
11, 14; 31, 34
Without function
21, 24; 41, 44
Without function
Parts supplied
1× Control unit
Enclosure with electronics module and plug-in connectors.
1× Operating Instructions
1× Declaration of Conformity
Ä
Upon receipt, immediately check the parts supplied to ensure they are com-
plete and in good condition.
Product overview
Connections
Ä
Store control units in a dry place inside the original packaging.
Ä
Observe the storage temperature in accordance with the technical data.
Storage