CAUTION:

    Connecting  the  MAXXFAN  to  a  circuit 

other than 12 Volts DC or with incorrect polarity could 

GDPDJH WKH 0$;;)$1 FDXVH LQMXU\ WR SHUVRQV RU

damage to property and void the warranty.

STEP 4

&RQ¿UPWKHPHWDOPRXQWLQJFOLSVDUH¿UPO\LQSODFHRQ

the  Roof  Receiving  Flange.    With  the  MAXXFAN  open 
and  the  exhaust/intake  louvers  facing  the  rear  of  the 
vehicle,  lower  the  MAXXFAN  onto  the  Roof  Receiving 
Flange.
Make  sure  the  power  wires  slide  to  the  vehicle  interior 
and  do  not  become  entangled  on  the  Roof  Receiving 
Flange’s upward edge.

STEP 5

Verify  the  MAXXFAN  is  fully  seated  down  on  the  Roof 
Receiving Flange and fasten the MAXXFAN to the Roof 
Receiving  Flange  using  the  four  19mm  #10  stainless 
steel screws provided.

CAUTION: 

2QO\XVHWKHVFUHZVSURYLGHGVSHFL¿HG

for this installation or internal damage and/or insecure 
mounting may result.

STEP 1
MAXXFAN

 requires a roof opening opeining of 355mm 

x 355mm for KI models and a roof opening of 400mm x 
400mm  for  KI40  models.    If  you  are  replacing  another 
type already installed, remove the old existing roof vent.   
Remove  all  old  roof  sealant  for  a  minimum  of  50mm 
entirely around the roof opening.

Place the  MAXXFAN Roof Receiving Flange (reference 
photo #2 below) into the roof opening and trace a pencil 
line  around  it  to  verify  the  clean  seal  area  that  will  be 
required.  Note that the Roof Receiving Flange must be 
centered  in  the  roof  opening  with  the  metal  clips  facing 
the sides of the vehicle (not facing the front or rear of the 
vehicle).

CAUTION: 

When  installing  your  Roof  Flange,  only 

XVH D FDXONLQJVHDODQW FRPSDWLEOH ZLWK WKH ÀDQJH

(plastic  product)  and  the  roof  surface.      DO  NOT 
use  materials  containing  solvents  such  as  or  similar 
to  Xylene,  Toluene,  Methyl  Ethyl  Ketone,  Acetate 

RU $FHWRQH DV WKH\ FDQ GDPDJH WKH ÀDQJH  $OVR

3RO\VXO¿GH7KLRNROW\SHVHDODQWVPXVWEHDYRLGHG

Silicone  Sealants  such  as  G.E.  Silicone  II  (non-
paintable) used for outdoor applications have proven 
to be suitable for this installation.

If  in  doubt,  please  contact  the  manufacturer  of  your 
RV for further information.

STEP 2

Apply Sealant or Caulking within the area you have traced 
on the roof with a pencil.  Apply it carefully to avoid gaps 
that may allow water to enter.
Fasten  the  Roof  Receiving  Flange  to  the  roof  with 
screws provided.
Apply additional roof sealant over the screw heads and 

DURXQGWKHHGJHRIWKHURRIÀDQJH

CAUTION: 

Disconnect  main  vehicle  power  before 

connecting 12 volt DC power to the 

MAXXFAN

!

NOTE:

  The 

MAXXFAN

 must be fully opened prior to 

proceeding to STEP 3.  Turn knob to fully raise the vent 
lid.

NOTE:

    On  the  NON-REMOTE  controlled  models,  the 

knob must be pulled out to unlock before turning.

STEP 3

Using  the  insulated  electrical  connectors  provided, 
connect the vehicle’s 12 volt power to the two MAXXFAN 
power wires.

NOTE:

  

The MAXXFAN

EODFNZLUHLGHQWL¿HGZLWKDWDJVKRZLQJ

(+) must be connected to the vehicle 12 volt (+) positive supply.

THIS COMPLETES THE ROOF TOP 

PORTION OF THE INSTALLATION

NOTE: 

 Re-apply 12 volt vehicle power.   The MAXXFAN will 

emit a beeping sound to indicate power is properly connected.   
In  addition,  the  Remote  Control  model  will  automatically 
close the vent cover.   If the MAXXFAN does not beep when 

SRZHULVFRQQHFWHGJREDFNWRVWHS&RQ¿UPWKDWSURSHU

connections were made and 12 volt power is on and available.   
This MAXXFAN incorporates a self-resetting fuse on the circuit 
board  located  in  the  ceiling  assembly.      It  can  be  reset  by 
removing and re-applying power.   If your fan fails to operate or 
needs reset, contact your AIRXCEL / MAXXAIR Distributor for 
assistance or solicit the aid of an electrical technician.

RECEIVING FLANGE

UPPER EDGE

METAL MOUNTING

CLIPS

4

OPEN / CLOSE 
KNOB

ROOF FLANGE

2

INSTALLATION INSTRUCTIONS - ALL MODELS

2

Содержание MAXXFAN Deluxe 5100KI

Страница 1: ...QGDUG URRI YHQW DQJH RXWHU UHDU HGJH The MAXXFAN is designed for a minimum roof thickness of 25 mm to a maximum of 90mm If your roof thickness is less than 25 mm build additional thickness at the ceil...

Страница 2: ...Q GDPDJH WKH DQJH OVR 3RO VXO GH 7KLRNRO W SH VHDODQWV PXVW EH DYRLGHG Silicone Sealants such as G E Silicone II non paintable used for outdoor applications have proven to be suitable for this install...

Страница 3: ...ring should be cut 6mm to 12 5mm longer than the dimensions measured at each corner In Picture 6 below the installation measures 90mm from the ceiling this is an example only to the Control Plate Aft...

Страница 4: ...ERATE the MAXXFAN with the screen removed CAUTIONS AND CARE OF YOUR MAXXFAN This product has been manufactured using prime UV stabilized Polymers for maximum toughness and durability However the use o...

Страница 5: ...se excessive force when operating Knob KEYPAD CONTROLS Use Keys on Keypad to control MAXXFAN functions see descriptions on next page INSECT SCREEN RETAINER KNOB Rotate all 4 knobs 1 2 turn to remove s...

Страница 6: ...t for the thermostat is 26 C The green LED will light to indicate WKH 0 1 LV LQ XWR 0RGH 7R DGMXVW IROORZ LQVWUXFWLRQV EHORZ If no previous thermostat temperature was entered or you wish to change a p...

Страница 7: ...0RGH FORVH WKH YHQW OLG DQG VKXW R WKH IDQ PRWRU THERMOSTAT SET TEMPERATURE TEMP Press this button to increase the Set Temperature for Auto Mode TEMP Press this button to decrease the Set Temperature...

Страница 8: ...ventilation du toit standard existante Le MAXXFAN est con u pour des toits ayant une paisseur minimum de 25 mm et maximum de 90 mm Si l paisseur de votre toit est inf rieure 25 mm augmentez l paisseu...

Страница 9: ...nch it base de silicone tel que G E Silicone II ne peuvent tre peints utilis s pour les ext rieurs se sont av r s convenables pour cette installation En cas de doute contactez le fabricant de votre ca...

Страница 10: ...er chaque c t La cadre doit tre coup e de 6 mm 12 5 mm de plus que les mesures prises de chaque c t Dans l image N 6 ci dessous l installation mesure 90 mm du plafond ceci n est qu un exemple au Panne...

Страница 11: ...rsque l cran est d mont ENTRETIEN DE VOTRE MAXXFAN Ce produit est fabriqu base de polym res stabilis s aux UV pour une r sistance et une durabilit maximales Toutefois l utilisation des produits chimiq...

Страница 12: ...cez pas trop de force lorsque vous utilisez le bouton PANNEAU DE COMMANDES Utilisez les touches du clavier pour commander les fonctions du MAXXFAN voir les descriptions sur la page suivante BOUTON DE...

Страница 13: ...ARCHE ARR T Le point de consigne initial du thermostat est de 26 C La LED verte s allumera pour signaler que le MAXXFAN est en 0RGH XWR 3RXU SURFpGHU DX UpJODJHV VXLYH OHV LQVWUXFWLRQV FL GHVVRXV Si a...

Страница 14: ...r ce bouton lorsque le Mode Auto est activ ce mode sera d sactiv le couvercle d vent se fermera et le moteur du ventilateur s arr tera THERMOSTAT SET TEMPERATURE THERMOSTAT DE R GLAGE DE LA TEMP RATUR...

Отзывы: