INFORMATION AND OPERATING GUIDE

FOR MAXXFAN

®

 

Deluxe

 MODELS

5100KI • 6200KI • 6200KIT • 7000KI • 7500KI • 7500KIT

5100KI40 • 6200KI40 • 6200KI40T • 7000KI40 • 7500KI40 • 7500KI40T

KNOB, VENT LID OPEN/CLOSE

Manual Opening Models

Pull to unlock prior to turning.  Rotate Knob 
clockwise  to  Close  Vent  Lid;  Rotate  Knob 
counter-clockwise to Open Vent Lid.  Push 
“IN” to lock when Vent Lid is open or closed.

Automatic Opening Models

Allows  closing  of  the  vent  lid  in  the  event 
of  RV  power  loss.    This  knob  does  not 
lock.    Do  not  push  in  or  pull  out.    Rotate 
knob clockwise to close vent lid; rotate knob 
counter-clockwise to open vent lid.

Do not use excessive force when operating 
Knob.

KEYPAD CONTROLS

Use  Keys  on  Keypad  to  control 
MAXXFAN
functions (see descriptions on next page).

INSECT SCREEN RETAINER KNOB

Rotate all 4 knobs 1/2 turn to remove screen.

Caution: Never operate fan with screen removed

THERMOSTAT TEMPERATURE SENSOR

CEILING FAN MODE

With the fan motor running, close the Vent Lid to enter Ceiling Fan Mode.  The fan 
motor will continue to run and circulate air within the RV cabin.

SERIAL NUMBER LABEL

The serial number label is located underneath the round insect screen.

NOTE: 

 The  MAXXFAN  is  designed  to  be  fully  opened  or  fully  closed  when  the 

vehicle is moving.

CAUTION:  When removing screen for cleaning, turn the MAXXFAN OFF and 
remove  the  vehicle  12  volt  power  to  the  MAXXFAN.    When  cleaning  your 
MAXXFAN, use only a mild detergent solution.

5

Содержание MAXXFAN Deluxe 5100KI

Страница 1: ...QGDUG URRI YHQW DQJH RXWHU UHDU HGJH The MAXXFAN is designed for a minimum roof thickness of 25 mm to a maximum of 90mm If your roof thickness is less than 25 mm build additional thickness at the ceil...

Страница 2: ...Q GDPDJH WKH DQJH OVR 3RO VXO GH 7KLRNRO W SH VHDODQWV PXVW EH DYRLGHG Silicone Sealants such as G E Silicone II non paintable used for outdoor applications have proven to be suitable for this install...

Страница 3: ...ring should be cut 6mm to 12 5mm longer than the dimensions measured at each corner In Picture 6 below the installation measures 90mm from the ceiling this is an example only to the Control Plate Aft...

Страница 4: ...ERATE the MAXXFAN with the screen removed CAUTIONS AND CARE OF YOUR MAXXFAN This product has been manufactured using prime UV stabilized Polymers for maximum toughness and durability However the use o...

Страница 5: ...se excessive force when operating Knob KEYPAD CONTROLS Use Keys on Keypad to control MAXXFAN functions see descriptions on next page INSECT SCREEN RETAINER KNOB Rotate all 4 knobs 1 2 turn to remove s...

Страница 6: ...t for the thermostat is 26 C The green LED will light to indicate WKH 0 1 LV LQ XWR 0RGH 7R DGMXVW IROORZ LQVWUXFWLRQV EHORZ If no previous thermostat temperature was entered or you wish to change a p...

Страница 7: ...0RGH FORVH WKH YHQW OLG DQG VKXW R WKH IDQ PRWRU THERMOSTAT SET TEMPERATURE TEMP Press this button to increase the Set Temperature for Auto Mode TEMP Press this button to decrease the Set Temperature...

Страница 8: ...ventilation du toit standard existante Le MAXXFAN est con u pour des toits ayant une paisseur minimum de 25 mm et maximum de 90 mm Si l paisseur de votre toit est inf rieure 25 mm augmentez l paisseu...

Страница 9: ...nch it base de silicone tel que G E Silicone II ne peuvent tre peints utilis s pour les ext rieurs se sont av r s convenables pour cette installation En cas de doute contactez le fabricant de votre ca...

Страница 10: ...er chaque c t La cadre doit tre coup e de 6 mm 12 5 mm de plus que les mesures prises de chaque c t Dans l image N 6 ci dessous l installation mesure 90 mm du plafond ceci n est qu un exemple au Panne...

Страница 11: ...rsque l cran est d mont ENTRETIEN DE VOTRE MAXXFAN Ce produit est fabriqu base de polym res stabilis s aux UV pour une r sistance et une durabilit maximales Toutefois l utilisation des produits chimiq...

Страница 12: ...cez pas trop de force lorsque vous utilisez le bouton PANNEAU DE COMMANDES Utilisez les touches du clavier pour commander les fonctions du MAXXFAN voir les descriptions sur la page suivante BOUTON DE...

Страница 13: ...ARCHE ARR T Le point de consigne initial du thermostat est de 26 C La LED verte s allumera pour signaler que le MAXXFAN est en 0RGH XWR 3RXU SURFpGHU DX UpJODJHV VXLYH OHV LQVWUXFWLRQV FL GHVVRXV Si a...

Страница 14: ...r ce bouton lorsque le Mode Auto est activ ce mode sera d sactiv le couvercle d vent se fermera et le moteur du ventilateur s arr tera THERMOSTAT SET TEMPERATURE THERMOSTAT DE R GLAGE DE LA TEMP RATUR...

Отзывы: