52
Chapter 6 Operation Guide
7-Startup Steps
WARN:
◎
Make sure that all electrical connections (including protective gas, plugging
in the ground wire) have been connected before use. If conditions permit, all
connectors must be tightened and fixed with screws.
◎
When operating the laser, do not look directly at the laser output port, and
strictly wear safety glasses and soundproof earplugs.
◎
When wiring, please turn off all the power switches of the laser first.
The startup process is as follows:
(1) Connect the power input to the indicated voltage, phase and frequency;
(2) The connection is securely locked to the loop interface, and the wire feeding
power cord is connected to the FEEDER interface;
(3) Connect the protective gas tube (6mm) to the gas in port, and open the gas
valve;
(4) Turn on the power switch on the rear panel of the laser;
(5) Release the emergency stop switch on the front panel of the laser;
(6) Click on the touch screen to enter the software interface, and adjust the
corresponding parameters (laser power, swing amplitude, swing frequency,
parameters such as air blowing and closing air delay, power rising and falling
slowly, light output mode, etc.);
(7) Adjust the air valve mode to normally open, and adjust the protective gas
flow rate ≥ 15L/min;
(8) Clamp the alligator clip on the workpiece to be welded;
(9) Turn on the laser start button and the laser enable switch;