32
Chapter 3 Product Description
Functional
Classification
Function
Description
Remark
Laser usage
alarm
Emergency stop
monitoring
The laser emergency stop alarm, please
check whether the emergency stop switch is
pressed, and contact the after-sales service
after confirming that it is correct.
Lock machine
monitoring
Laser lock alarm, please do not weld high-
reflection plates, and try again after restoring
to factory settings.
Use expiration
monitoring
The laser usage expires alarm, please check
whether the machine has expired, and after
confirming it is correct, contact the after-sale
service to obtain an authorization code to
extend the usage time.
Temperature
and humidity
alarm
Optical Module
Temperature
Monitoring
Alarm when the temperature exceeds the
threshold, please check whether the air outlet
is blocked and whether the filter is dirty,
and clean the air outlet and filter in time;
do not work for a long time in a place with
high ambient temperature; check whether
all fans are running normally, if there is
any abnormality, please contact After-sales
processing.
Optical Module
Humidity Monitoring
Electric cold
plate temperature
monitoring
Light cold plate
temperature
monitoring
Pump source
temperature
monitoring
Current alarm
Pump 1 current
monitoring
If the current exceeds the threshold, please
try again after restoring the factory settings. If
the fault still exists, please contact the after-
sales service.
Pump 2 current
monitoring
Pump 3 current
monitoring
Pump 4 current
monitoring
Red photocurrent
monitoring