1
1921 Slauson
A
ve. Santa Fe Springs, CA. 90670 (800) 227-41
16 F
AX (888) 771-7713
45
FIG. 45-1
LOWER PORT
RAISE PORT
5.
Check the hydraulic cylinder. With the platform at
vehicle
fl
oor level, remove the hydraulic line from
the
LOWER
port on the cylinder
(FIG. 45-1)
. Hold
the control switch in the “
RAISE
” position for two
seconds while you watch for hydraulic
fl
uid at the
LOWER
port. A few drops of hydraulic
fl
uid escap-
ing the port is normal. However, if
fl
uid streams
out, piston seals are worn. Replace seals.
6.
If pump cannot produce 3250 PSI or
lift the load capacity with a minimum of
12.6 volts available, the pump is worn
and needs to be replaced.