1
1921 Slauson
A
ve. Santa Fe Springs, CA. 90670 (800) 227-41
16 F
AX (888) 771-7713
14
CHECKING HYDRAULIC FLUID
CAUTION
Keep dirt, water and other contaminants from entering the hydraulic system.
Before opening the hydraulic fl uid reservoir fi ller cap, drain plug and hydrau-
lic lines, clean up contaminants that can get in the openings. Also, protect the
openings from accidental contamination.
+50 to +120 Degrees F - Grade ISO 32
Below + 70 Degrees F - Grade ISO 15 or MIL-H-5606
NOTE:
Use correct grade of hydraulic
fl
uid for your location.
See
TABLES 15-1 & 15-2
for recommended brands.
PERIODIC MAINTENANCE
1.
Unbolt and remove pump cover
(FIG. 14-1)
.
UNBOLTING/BOLTING PUMP COVER
FIG. 14-1
3.
If needed, add
fl
uid to the reservoir as fol-
lows. Pull out (no threads)
fi
ller cap
(FIG.
14-2)
. Fill the reservoir with hydraulic
fl
uid to
level shown in
FIG. 14-2
. Reinstall
fi
ller cap
(FIG. 14-2)
.
2.
Check the hydraulic
fl
uid level
in reservoir as follows. With
Liftgate stowed, or platform at
vehicle bed height, level should
be as shown in
FIG. 14-2
.
CAUTION
Pump cover must be correctly
secured to prevent it from be-
coming a hazard. To secure pump
cover, the long side of the holder
fl ats must butt against pump cov-
er as shown in the illustration.
4.
Bolt on the pump cover as shown
in
FIG. 14-1
. Torque the bolts (cap
screws) to
10-14 lb-in
.
CAP SCREW,
5/16”-18
(2 PLACES)
HOLDER FLAT
(2 PLACES)
FLAT WASHER,
5/16”
(2 PLACES)
NYLON NUT,
5/16”-18
(2 PLACES)
PUMP COVER
POWER UNIT
(REF)
POWER UNIT FLUID LEVEL
FIG. 14-2
FILLER
CAP
RESERVOIR
3”(PD)
1-1/2”(GD)
Содержание TE-250C
Страница 1: ...M 17 12 REV B APRIL 2020 2020 MAXON Lift Corp...
Страница 2: ......
Страница 7: ...THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 21: ...11921 Slauson Ave Santa Fe Springs CA 90670 800 227 4116 FAX 888 771 7713 21 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 27: ...11921 Slauson Ave Santa Fe Springs CA 90670 800 227 4116 FAX 888 771 7713 27 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 48: ......