STEP 2 - WELD LIFTGATE TO VEHICLE - Continued
5.
Clamp both mounting plates
to vehicle frame. Check
the distance between bed
level and top of main frame.
Maintain the distance shown
in
FIG. 24-1
.
VEHICLE FRAME CUTOUT
(TYPICAL TRUCK
FRAME SHOWN)
MOUNTING
PLATE
BED LEVEL
WELD TO VEHICLE FRAME AND MAIN FRAME
(RH SIDE SHOWN)
FIG. 24-1
2” LG. 4 PLACES
(TYPICAL - RH & LH
MOUNTING PLATES)
5/16”
6.
Weld the mounting plates to
vehicle frame as shown in
FIG. 24-1
. Remove clamps.
* TOLERANCE IS +/- 1/4”
Prevent damage to hydraulic hoses. If welding next to hydraulic hoses, use a
protective cover such as a welding blanket to cover the hoses.
CAUTION
To protect the original paint system if equipped, a 3” wide area of paint must
be removed from all sides of the weld area before welding.
CAUTION
MAIN
FRAME
CAUTION
When using an electric welder, connect the welder ground to one of the parts
being welded, as close to the weld as possible. Failure to comply could result
in damage to cylinders and electrical parts.
* 23-1/4” (GPTLR-25/-33)
* 24-1/2” (GPTLR-44/-54)