1
1921 Slauson
A
ve. Santa Fe Springs, CA. 90670 (800) 227-41
16 F
AX (888) 771-7713
37
STEP 6 - CONNECT GROUND CABLE - Continued
NOTE:
If there is a grounding point on the frame, use it to connect ground cable.
Then, skip the step for drilling a hole.
4.
Extend the ground cable to reach
vehicle frame
(FIG. 37-1)
without
putting tension on cable (after con-
nection). Connect to an existing
grounding point if available.
7.
Bolt the ground cable terminal
lug to vehicle frame as shown in
FIG. 37-1
.
NOTE:
Clean the ground cable connection point on the frame down to bare metal.
5.
If necessary, drill a 11/32” (0.343”)
hole in vehicle frame for bolting
the ground cable terminal lug
(FIG. 37-1)
.
FIG. 37-1
TERMINAL LUG
(GROUND CABLE)
5/16"-18 X 1" LG
CAP SCREW
5/16” FLAT
WASHER
5/16”-18
LOCK NUT
VEHICLE CHASSIS
(TRUCK FRAME SHOWN)
BARE
METAL
6.
To prevent corrosion
,
paint or
use galvanized spray on bare
metal area
FIG. 37-1
.