STEP 11 - ADJUST PLATFORM (IF REQUIRED)
- Continued
WARNING
!
To prevent accidental personal injury and equipment damage, make sure
power is disconnected from Liftgate while installing parts.
10.
Disconnect power to the pump by
disconnecting negative
(-)
and
positive
(+)
cables from battery
(FIG.
52-1)
. Reinstall nuts on negative
(-)
and positive
(+)
battery terminals.
POSITIVE (+)
BATTERY POST
NEGATIVE (-)
BATTERY CABLE
NEGATIVE (-)
BATTERY POST
NUT
POSITIVE (+)
BATTERY CABLE
DISCONNECTING BATTERY POWER
FIG. 52-1
11.
Support the Liftgate under main
frame with a
fl
oor jack
(FIG.
52-2)
.
FLOOR JACK
MAIN FRAME
SUPPORTING LIFTGATE
FIG. 52-2
Содержание GPTLR-25