Specifications
Technical Data
maxon motor control
EPOS4 Positioning Controller
Document ID: rel8399
2-13
EPOS4 Module/Compact 50/8 Hardware Reference
Edition: November 2018
© 2018 maxon motor. Subject to change without prior notice.
Table 2-5
Technical data
Environ-
mental
Conditions
Temperature
Operation
Module:
−30…+45 °C
Compact: −30…+45 °C
Extended range
1)
+45…+77 °C
Derating −0.250 A/°C (
Storage
−40…+85 °C
Altitude
2)
Operation
0…6’000 m MSL
Extended range
1)
6’000…10’000 m MSL
Derating
Humidity
5…90% (condensation not permitted)
1)
Operation within the extended range (temperature and altitude) is permitted. However, a respective derating
(declination of output current I
cont
) as to the stated values will apply.
2)
Operating altitude in meters above Mean Sea Level, MSL.
EPOS4 Module 50/8 (504384)
EPOS4 Compact 50/8 CAN (520885)
EPOS4 Compact 50/8 EtherCAT (605298)