Setup
Pin Assignment for Connector Boards & Compact Versions
maxon motor control
3-46
Document ID: rel8399
EPOS4 Positioning Controller
Edition: November 2018
EPOS4 Module/Compact 50/8 Hardware Reference
© 2018 maxon motor. Subject to change without prior notice.
3.3.6.2
CAN automatic Bit Rate Detection (Compact CAN)
Table 3-43
DIP switch SW1 – CAN automatic bit rate detection
3.3.6.3
CAN Bus Termination (Compact CAN)
Table 3-44
DIP switch SW1 – CAN bus termination
3.3.6.4
Digital Input Level
For details
chapter “3.4.7 Digital I/Os” on page 3-64.
Table 3-45
DIP switch SW1 – Digital input level
3.3.7
Spare Parts
Table 3-46
Spare parts list
Controller
Switch
OFF
ON
Compact
CAN
6
Automatic bit rate detection
deactivated
Automatic bit rate detection activated
(factory setting)
Controller
Switch
OFF
ON
Compact
CAN
7
Without bus termination
(factory setting)
Bus termination with 120 Ω
Controller
Switch
OFF
ON
Compact
CAN
8
Logic level
(factory setting)
PLC level
Compact
EtherCAT
6
Logic level
(factory setting)
PLC level
Order
number
Description
520860
STO Idle Connector X9