29
The machine must be connected by a certified electrician. A 1x16A fuse and 30mA
current leakage fuse should be used at a maximum height of 170cm for the 230V
machine. For the 400V machine you should use a 3x16A fuse.
The protective film on the machine must be removed first after installing the
machine.
The power supply cable (3x2.5 mm2 H07 RNF), water supply connection (3/4) and
water drain hose come with the machine
Where the machine is installed, at a height of 25/75cm there should be a ½ water
supply with ¾ valve for the fresh water inlet of the machine. At a height of about
2cm there should be a drain pipe in the wall or ground where the machine is placed.
When using the VNG350 Ultra this may be put higher (Max 70CM).
A ventilation system with ventilation hood should be present where the machine is
installed. The user must ensure that the control and electricity in the machine
remains free from moisture, condensation and vapour.
The leveling feet are height-adjustable. They should be adjusted according to the
ground floor and entry and exit stands, allowing the machine to operate in a leveled
position.
The manufacturer will not take responsibility for any damage or problems to the
machine or other machines, caused by other machines that are connected to the
same power board, supplying power to the machine. For this reason we advise you
to use a separate group/board for the machine.
Troubleshooting
1. Is the power supply connected properly and are the cables still good and not worn?
The earth installation for the power supply work, must be constructed
complying with the effective grounding regulations and must be evidenced
by certificates issued by relevant authorities. The service personnel who will
install the machine need to ground the machine with a cable connected to
the power supply, and connected to thegrounding end of the machine cable.
Only after this is done the water connections should be done and then the
machine can be operated. Make sure that all safety regulations are taken
into account while installing the machine. The manufacturer/importer and
dealer will not be responsible for any injuries, damage or other
consequences caused by not following the safety regulations.
Caution: Do not start or use the machine without connecting it to the
earth cable first.