 Protection

14

Features of protector

Inspection

Noise pollution

Operating condition

The protective device maybe trip and stop
the appliance in the cases listed below:

 HEATING

o

Outdoor air temperature is over 24

c

COOLING

DRY

o

Outdoor air temperature is below -5

c

o

Room  temperature is over 27

c

o

Outdoor air temperature is over 43

c

o

Room temperature is below 21

c

o

Room temperature is below 18

c

If the air conditioner runs in "COOLING" or
"DRY" mode with door or window opened
for a long time when relative humidity is above
85%, dew may drip down from the air outlet.

The protective device will work at
following cases:

Stopping the appliance and restarting it
at once or changing mode during
operation, you need to wait 3 minutes.

Switch on power supply and turning on
the appliance at once, you need to wait
about 20 seconds.

If all operation has stopped, press
 "ON/OFF" button to restart.
Set timer again if it has been canceled.

After using for a long time , the air
conditioner should be inspected on
the following items:

Overheat of the power supply cord
and plug or even a burned smell.

Abnormal operating sound or vibration.
Water leakage from indoor unit.
Metal cabinet electrified .

Stop the air conditioner if above trouble
occurs.

It is advisable to have a detail inspection
after using it for 5 years even if none of
the above occurs.

Install the air conditioner at a place 
that can bear its weight in order to
operate more quietly.

 Install the outdoor unit at a place 
 where the air discharged and the
 operation noise would not annoy 
 your neighbors.

Do not place any obstacles in front of 
the air outlet of the outdoor unit for
fear it increases the noise level.

Features  of HEATING mode

Features  of HEATING mode

Preheat

It is hard to raise the room temperature when outdoor temperature is very low. Use the air 
conditioner together with other heating appliance in this case. 

Defrost

At the beginning of HEATING operation, the airflow from indoor unit is discharged 2-5
minutes later.

In HEATING operation the appliance will defrost (de-ice) automatically to raise efficiency.
This procedure usually lasts 2-10 minutes. During defrosting, fans stop operation. 
After defrosting completes, it returns to "HEATING" mode automatically.

Содержание CLK120H4C

Страница 1: ...EEL mode Timer operation mode Electric heating mode Sleep operation mode Safety Precautions Maintenance Protection Troubleshooting Installation instructions Select the installation locations Indoor un...

Страница 2: ...roken An electric shock or fire is probably caused by a broken power supply cord Never insert a stick or similar to the unit Since the fan rotates at high speed this may cause an injury Do not repair...

Страница 3: ...del Consequently the shape may differ from that of the air conditioner you have selected Air vanes Air outlet Electrical cover Note The condensate water drains at COOLING or Dry operation Drain hose P...

Страница 4: ...the electrical heater is in use and lights off when heater is off Receives signal from the remote controller Timer indicator Yellow Drain indicator Orange Electrical heater indicator Red Signal receiv...

Страница 5: ...igh fan speed medium fan speed low fan speed For adjusting room temperature Remote controller signal transmitter ON OFF button TIMER button HEATER button TIMER SET button MODE button FAN Speed button...

Страница 6: ...ones of the same tape To prevent liquid leakage take out all batteries when it is not going to be used for a long time After replacing batteries if the remote controller does not display take them ou...

Страница 7: ...ing temperature Press once to lower temperature by 1 Press once to raise temperature by 1 Range of available set temperature HEATING or COOLING DRY FAN unable to set room temperature Turning on Press...

Страница 8: ...covered with dust just wipe it off with a soft cloth It is better not to allow the air vanes tilt downward for a long time at COOLING or DRY operation mode to prevent dew from forming and dripping dow...

Страница 9: ...arts to function When temperature reaches a certain point the electric heater will stop automatically and restart once temperature decreases to a certain point Press the HEATER button in electric heat...

Страница 10: ...hours As time goes by LCD displays the remained time The previous set time is stored and the next set time begins with the previous set one On timer and off timer can not be set at the same time The...

Страница 11: ...for sleep The unit turns off automatically after 8 hours if SLEEP mode is set It is recommended to use SLEEP mode together with OFF TIMER to achieve a more economical and energy saving operation After...

Страница 12: ...ill Open the air inlet grill Grasp the bottom corners of the air filter and pull downward Remove the air filter Never use volatile substance such as gasoline or polishing powder to clean the unit shoc...

Страница 13: ...r Reinstall the air inlet grill to the indoor unit Remove the dusts from the air filter with a vacuum cleaner Clean it with water and neutral detergent Dry it throughly in a cool and shaded place Wash...

Страница 14: ...ing items Overheat of the power supply cord and plug or even a burned smell Abnormal operating sound or vibration Water leakage from indoor unit Metal cabinet electrified Stop the air conditioner if a...

Страница 15: ...check it before asking for service If strong interference from excessive static electricity discharge power supply voltage abnormality presents operation will be abnormal At this time disconnect from...

Страница 16: ...ng board 2m 3 5m above the ground Avoid installing it at the roadside where there is a risk of muddy water Where your neighbors would not be annoyed by operating noise and hot airflow discharged A fix...

Страница 17: ...ckets Cut an opening 880x880 on the ceiling board with assistance of the moulding board make sure to follow the same direction of the holes for roof bolts Fix the edges of the opening with the shaped...

Страница 18: ...suspending poles allow the bottom of the unit 8 13mm higher than that of the ceiling board as the above figure shown Then adjust each corner of the bottom horizontally with a leveling ruler Levelness...

Страница 19: ...pump here Wall hole Piping and cable connection Drill a wall hole if the pipes and cables through the wall The hole should tilt a little downward as shown below for easy drainage For cleanness of the...

Страница 20: ...edure should be done after leak test Wrap the all the joints well otherwise dew may form and drips The gas pipe and liquid pipe should be taped and wrapped separately Adjust the position of pipes and...

Страница 21: ...s from 2 and 3 way valves 4 Start vacuum pump for 10 15 minutes until reaching a vacuum of 10 mm Hg absolutes 6 Open 2 way valve 1 4 turn then close it after 10 seconds Check tightness of all joints u...

Страница 22: ...ner dia 25mm outer dia 32mm of the drain hose to the drain port of the main unit then clamp it well Measure the distance from the drain pipe to the outside of wall then cut a PVC tube of according to...

Страница 23: ...oor and outdoor units are too long use a cable of larger section area to avoid voltage decrease 2 2 The ground wire for the whole unit is 2 5mm which should be prepared by the user Keep the cables awa...

Страница 24: ...iring optionally Make sure to fix the wires well Incomplete connection or fixing of wire could result in a fire Power supply cord Electric heater power cord Defrost cable Terminal Control board Contro...

Страница 25: ...O r a n g e O r a n g e V i o l e t V i o l e t V i o l e t V i o l e t Yellow Green Blue Blue Brown R e d R e d R e d W hi te B l a c k 25 SINGLE PHASE MODEL SINGLE PHASE MODEL 3 PHASE MODEL 3 PHASE...

Страница 26: ...a ck Bla ck O r a n g e Y e l l o w O r a n g e Yellow V i o l e t V i o l e t Yellow Green Blue R e d R e d W h it e B la c k W hi te B l a c k 26 Installation instructions Electrical work For 41K Ou...

Страница 27: ...through a funnel Normally the floater switch can be seen floating up from the checking opening and the water pump starts to drain which can be seen through the transparent drain port If not check the...

Страница 28: ...he 4 corners until it adhere to the ceiling board tightly Restrict the sponge between the front panel and indoor unit to 5 8mm allowing each side of the unit fits well with the front panel to avoid ai...

Страница 29: ...t Do not let air enter the refrigeration system or discharge refrigerant when moving the air conditioner Testing run the air conditioner after finishing installation and record details of operation Ra...

Отзывы: