Safety
and
Installation
Instructions
for
AC
Modules
IMPORTANT
SAFETY
INSTRUCTIONS
SAVE
THESE
INSTRUCTIONS
1.0
Introduction
This
document
provides
safety
and
installation
instructions
for
the
Maxeon
AC
photovoltaic
(PV)
modules
described
herein,
all
of
which
bear
both
TUV
and
EnTest
logos
on
the
product
label
in
respect
to
DC
and
AC
(Microinverter)
standards:
1.1
Definition
of
Terms
AC
Module:
Maxeon
5
AC
module
DC
Module:
A
typical
photovoltaic
solar
module
without
microinverter
unit
attached.
Enphase
Microinverter:
Smart
grid
ready
IQ
7A
microinverter
converts
the
DC
output
of
the
PV
module
into
grid
‐
compliant
AC
power.
Enphase
AC
cable:
also
called
Q
Cable,
it
is
an
AC
cable
with
a
length
varying
from
1.3m
to
2.3m
depending
to
AC
Module
orientation
(Portrait
or
Landscape),
with
3.3
mm2
cross
section,
double
insulated,
outdoor
rated
with
integrated
connectors
for
microinverters.
AC
Module
plug
directly
into
the
cable
connectors.
Enphase
Enlighten:
Web
‐
based
monitoring
and
management
software.
Installers
can
use
Enlighten
Manager
to
view
detailed
performance
data,
manage
multiple
PV
systems,
etc.
DC
Connector:
Maxeon
recommends
using
the
same
brand
connector
in
a
given
PV
system.
Approved
compatible
connectors:
Tyco
Electronics
PV4S
1.2
Disclaimer
of
Liability
The
installation
techniques,
handling
and
use
of
this
product
are
beyond
company
control.
Therefore,
Maxeon
Solar
Technologies
does
not
assume
responsibility
for
loss,
damage,
or
expense
resulting
from
improper
installation,
handling,
or
use.
1.3
Certified
Body
Certification
Information
This
product
intents
to
meet
or
exceed
the
requirements
set
forth
by
IEC
62109
‐
3
for
Maxeon
AC
modules
(not
yet
released).
The
IEC
62109
‐
3
Standard
covers
flat
‐
plate
PV
modules
intended
for
installation
on
buildings;
or
those
intended
to
be
freestanding.
The
TUV
certification
does
not
include
integration
into
a
building
surface
because
additional
requirements
may
apply.
This
product
is
not
intended
for
use
where
artificially
concentrated
sunlight
is
applied
to
the
module.
This
manual
shall
be
used
in
combination
with
industry
recognized
best
practices
and
AC
modules
should
be
installed
by
certified
professionals
only.
1.4
Limited
Warranty
AC
Module
limited
warranties
are
described
in
the
Maxeon
Solar
Technologies
warranty
certificates
obtainable
at
www.sunpower.maxeon.com
(Refer
to
the
limited
warranty
document).
2.0
Safety
Precautions
Before
installing
this
device,
read
all
safety
instructions
in
this
document.
Disconnect
the
AC
source
from
all
AC
Modules
and/or
cover
all
modules
in
the
PV
array
with
an
opaque
cloth
or
material
before
making
or
breaking
electrical
connections
Do
not
connect
or
disconnect
modules
when
current
from
the
modules
in
the
string
or
an
external
source
is
present
Use
only
the
AC
locking
connectors
in
order
to
defend
against
untrained
personnel
disconnecting
the
modules
after
they
have
been
installed.
All
installations
must
be
performed
in
compliance
with
the
applicable
local
codes.
Installation
should
be
performed
only
by
qualified
and
suitably
licensed
personnel
Remove
all
metallic
jewelry
prior
to
installing
this
product
to
reduce
the
chance
of
accidental
exposure
to
live
circuits.
Use
only
insulated
tools
to
reduce
your
risk
of
electric
shock.
Do
not
stand
on,
drop,
scratch,
or
allow
objects
to
fall
on
AC
Modules.
Broken
glass,
J
‐
boxes,
broken
connectors,
and/or
damaged
backsheets
are
electrical
hazards
as
well
as
laceration
hazards.
If
a
module
is
cracked
after
installation,
a
qualified
person
should
remove
the
module
from
the
array
and
contact
the
supplier
for
disposal
instructions.
Do
not
install
or
handle
modules
when
they
are
wet
or
during
periods
of
high
wind.
Unconnected
connectors
must
always
be
protected
from
pollution
(e.g.
dust,
humidity,
foreign
particles,
etc.),
prior
to
installation.
Do
not
leave
unconnected
(unprotected)
connectors
exposed
to
the
environment.
A
clean
installation
environment
is
essential
in
order
to
avoid
performance
degradation.
Do
not
block
drain
holes
or
allow
water
to
pool
in
or
near
AC
Module
frames
Contact
your
module
supplier
if
maintenance
is
necessary.
Save
these
instructions!
3.0
Electrical
Characteristics
Electrical
characteristics
and
grid
interaction
data
are
shown
in
Table
3
and
AC
Module
datasheet.
It
is
the
installer’s
responsibility
to
set
the
grid
profile
and
to
check
Enphase
pre
‐
configured
country
grid
detail
and
this
can
be
done
with
internet
access
and
by
connecting
into
the
Enphase
Enlighten
system.
If
an
installation
involves
a
Maxeon
AC
module
which
does
not
appear
on
this
list,
please
consult
the
product
label
on
the
back
of
the
module
or
visit
www.sunpower.maxeon.com
for
the
product
datasheet.
As
a
reminder
for
DC
modules:
a
photovoltaic
module
may
produce
more
current
and/or
voltage
than
reported
at
STC.
Sunny,
cool
weather
and
reflection
from
snow
or
water
can
increase
current
and
power
output.
Therefore,
the
values
of
Isc
and
Voc
marked
on
the
module
should
be
multiplied
by
a
factor
of
1.25
when
determining
component
voltage
ratings,
conductor
ampacities,
fuse
sizes,
and
size
of
controls
connected
to
PV
output.
An
additional
1.25
multiplier
may
be
required
by
certain
local
codes
for
sizing
fuses
and
conductors.
SunPower
recommends
the
use
of
open
‐
circuit
voltage
temperature
coefficients
listed
on
the
datasheets
when
determining
Maximum
System
Voltage.
3.1
Fire
Rating
The
AC
Module
maintains
the
same
Class
C
fire
rating
associated
with
DC
modules.
4.0
Electrical
Connections
Modules
must
only
be
connected
using
the
correct
Enphase
AC
cable
and
integrated
connectors.
Do
not
alter
any
connectors.
Important!
Please
read
these
instructions
in
their
entirety
before
installing,
wiring,
or
using
this
product
in
any
way.
Failure
to
comply
with
these
instructions
will
invalidate
the
Maxeon
Solar
Technologies
Limited
Warranty
for
PV
Modules
and
Enphase
Energy
Limited
Warranty
for
microinverters.
Danger!
AC
Modules
generate
internal
direct
current
(DC)
and
output
alternating
current
(AC);
and
are
a
source
of
voltage
when
under
load
and
when
exposed
to
light.
Electrical
currents
can
arc
across
gaps
and
may
cause
injury
or
death
if
improper
connection
or
disconnection
is
made;
or
if
contact
is
made
with
module
leads
that
are
frayed
or
torn.
ENGL
ISH