8–2
SPECIFICATIONS
www.maxcessintl.com
MAGPOWR DLCA
MI 850A348 1 E
Inputs and outputs
Load cell excitation - 5 VDC or 7.5 VDC, 100mA Maximum
Load cell sensitivity - 1.5 to 100 mV/V
0-10V analog output - 0 to 10 VDC, 2k minimum load
4-20mA analog output - 4 to 20 mADC, 450 ohm maximum load
0-1mA or 0-10V analog output - 0-1 mADC, 1k maximum load
0-10 VDC, open circuit
Alarm output - 30 VDC maximum, 0.4 ADC maximum,
40 VDC isolation
Digital input (zero tension) - 24 VDC maximum, 5V or 24V selectable threshold
Temperature drift
Tension display - Max null drift: 0.02% of load cell rating per °C
0-10V output - Max null drift: 0.02% of load cell rating per °C
4-20mA output - Max null drift: 0.02% of load cell rating per °C
0-1mA / 0-10V output - Max null drift: 0.07% of load cell rating per °C
Certifications and
environmental compatibility
Product certifications – CE
TUV Rheinland of North America
to UL61010-1
and
CAN/CSA-C22.2 No. 61010-1 and
CB Certificate to IEC61010-1
RoHS