5–5
PARAMETERS
www.maxcessintl.com
MAGPOWR DLCA
MI 850A348 1 E
Miscellaneous
Parameter # Description
Default
P.19
Tension number format
Tells whether tension display is 3-digit with no fixed right-hand
zero or 3-digit with fixed right-hand zero.
0
0 = Auto Select between formats. (Based on value in
Maximum Tension C1.3 or C2.5).
1 = 3-digit with no fixed right-hand zero.
2 = 3-digit with fixed right-hand zero.
P.20
Tension polarity
Set to -1 to show positive tension when the force is acting in
the direction opposite the force direction arrow on the load
cells. Set automatically by Precision calibration.
+1
P.21
DP position
Set the decimal point position to show when displaying tension
0
0 = 0000
1 = 0000.
2 = 000.0
3 = 00.00
4 = 0.000
P.22
Lock out zeroing tension from [
] button and digital input when
a password has locked the DLCA.
0
0 = Zeroing tension allowed when password has locked the
DLCA
1 = Zeroing tension locked out when password has locked
the DLCA
P.23
Firmware Version. Displays the firmware version.
P.24
Exit from menu and return to displaying tension