Entering maximum tension
continued
Example 2
Using two GTSB-2200 load cells:
The rated load is 4400 lbs.
The application’s maximum tension is 2000 lbs.
Enter decimal point position as 00.00.
Enter Maximum tension as 2.00.
The DLCA now displays tension with units of 1000 lbs.
The display will increment in 10 lb steps.
Alternatively:
Enter decimal point position as 0000.
Enter maximum tension as 2000.
The DLCA will now display tension with units of 1 lbs.
The display will increment in 10 lb steps.
Note that the right-most zero is fixed and does not