78 Appendix B: Technical information
The pinout for auxiliary I/O connector C is as follows for Matrox Rapixo CL
Pro DB and QB. It can be accessed through either a DB-15 or DB-9 connector
using one of the two adapter brackets.
Pin on
DB-15
Pin on
DB-9
Hardware signal
name
MIL constant
for auxiliary
signal
Digitizer
device
number for
auxiliary
signal
Description
1
1
TTL_AUX_IO_12
M_AUX_IO8
M_DEV1
TTL auxiliary signal (input/output) for acquisition path 1,
which supports: user input, user output (M_USER_BIT2 on
M_DEV1), or trigger input (trigger controller 0 on acq path 1).
2
-
TTL_AUX_IO_13
M_AUX_IO9
M_DEV1
TTL auxiliary signal (input/output) for acquisition path 1,
which supports: timer output (M_TIMER1 on M_DEV1),
trigger input (trigger controller 1 on acq path 1), user input, or
user output (M_USER_BIT3 on M_DEV1).
3
-
TTL_AUX_IO_14
M_AUX_IO3
M_DEV0/
M_DEV1
TTL auxiliary signal (input/output), shared between
acquisition paths 0 and 1 for trigger input (trigger controller 3
on acq path 0; 3 on acq path 1), user input, user output
(M_USER_BIT5 on M_DEV0/M_DEV1), and dedicated to
acquisition path 1 for timer output (M_TIMER2 on M_DEV1).
4+,5-
8+,3-
LVDS_AUX_IN10
M_AUX_IO4
M_DEV0/
M_DEV1
LVDS auxiliary signal (input), shared between acquisition
paths 0 and 1 for trigger input (trigger controller 2 on acq path
0; 2 or 0 on acq path 1) or user input, and dedicated to
acquisition path 1 for quadrature input bit 0.
6+,8-
-
LVDS_AUX_IN11
M_AUX_IO5
M_DEV0/
M_DEV1
LVDS auxiliary signal (input), shared between acquisition
paths 0 and 1 for trigger input (trigger controller 1 or 3 on acq
path 1; 3 on acq path 0) or user input, and dedicated to
acquisition path 1 for timer-clock input or quadrature input bit
1.
7
6
GND
N/A
N/A
Ground.
10
-
GND
N/A
N/A
Ground.
12+,11-
4+,5-
OPTO_AUX_IN9
M_AUX_IO1
M_DEV0/
M_DEV1
Opto-isolated auxiliary signal (input), shared between
acquisition paths 0 and 1 for trigger input (trigger controller 1
or 3 on acq path 1; 3 on acq path 0) or user input.
13+,14-
-
LVDS_AUX_OUT15
M_AUX_IO12
M_DEV1
LVDS auxiliary signal (output) for acquisition path 1, which
supports: timer output (M_TIMER1/M_TIMER2 on M_DEV1)
or user output (M_USER_BIT0 on M_DEV1).
15+,9-
7+,2-
OPTO_AUX_IN8
M_AUX_IO0
M_DEV0/
M_DEV1
Opto-isolated auxiliary signal (input), shared between
acquisition paths 0 and 1 for trigger input (trigger controller 0
or 2 on acq path 1; 2 on acq path 0) or user input.
-
9
NC
Not connected.
Содержание Rapixo CL Pro
Страница 1: ...Matrox Rapixo CL Pro Installation and Hardware Reference Manual no Y11522 101 0100 August 7 2020...
Страница 6: ......
Страница 18: ...18 Chapter 1 Introduction...
Страница 64: ...64 Appendix A Glossary...
Страница 86: ...86 Appendix B Technical information...
Страница 95: ...Limited warranty Refer to the warranty statement that came with your product...
Страница 96: ......