28 Chapter 2: Hardware installation
To fix this problem, you must adjust your DCF. To do so:
1. Set your camera to generate images that contain as many different pixel values as
possible for every tap (for example, a test pattern containing a horizontal ramp).
Refer to your camera’s documentation for more information. If your camera does
not have a test-pattern mode, select an image similar to a horizontal ramp.
2. Once the test pattern (or sample image) is available, use the
Deseralizer
tool. This
tool will adjust values within your DCF to compensate for signal degradation due
to the long cables. This tool is available on the
Rapixo CL
page of the MILConfig
utility. Follow all on-screen instructions.
When the process is complete, your camera’s DCF is updated. Any MIL
application that uses this DCF in the same physical environment should now be
able to receive better images (using your camera as a video source).
❖
Note that, if your MILConfig utility does not have the
Deserializer
tool, contact
Matrox Technical Support for assistance.