Connectors on Matrox Rapixo CL Pro boards 73
Matrox Rapixo CL
Pro DB and QB
On Matrox Rapixo CL Pro DB, there are two Camera Link connectors; whereas
on Matrox Rapixo CL Pro QB, there are four Camera Link connectors. Each
Camera Link connector on Matrox Rapixo CL Pro DB and QB supports one
video source in Base configuration, and has the same pinout; this pinout is listed
in the following table.
Pin
Hardware signal
name
MIL constant for
auxiliary signal
Description
1
Inner shield
Ground (inner shield), or +12V to camera in PoCL mode.
3+,16-
CC3
M_CC_IO3
Camera control output 3 for acquisition path n, which supports: timer output
(M_TIMER1/M_TIMER2 on M_DEVn), user output
(M_USER_BIT_CC_IO0/M_USER_BIT_CC_IO1 on M_DEVn), VSYNC, HSYNC,
clock output, or rerouting of specific auxiliary input signals
*
.
5+,18-
CC1
M_CC_IO1
Camera control output 1 for acquisition path n, which supports: timer output
(M_TIMER1/M_TIMER2 on M_DEVn), user output
(M_USER_BIT_CC_IO0/M_USER_BIT_CC_IO1 on M_DEVn), VSYNC, HSYNC,
clock output, or rerouting of specific auxiliary input signals
†
.
6+,19-
SerTFG
Serial port to frame grabber (UART).
8+,21-
X3
Video input data X3.
9+,22-
Xclk
Clock input X.
10+,23-
X2
Video input data X2.
11+,24-
X1
Video input data X1.
12+,25-
X0
Video input data X0.
13
Inner shield
Ground.
14
Inner shield
Ground.
15+,2-
CC4
M_CC_IO4
Camera control output 4 for acquisition path n, which supports: timer output
(M_TIMER1/M_TIMER2 on M_DEVn), user output
(M_USER_BIT_CC_IO0/M_USER_BIT_CC_IO1 on M_DEVn), VSYNC, HSYNC,
clock output, or rerouting of specific auxiliary input signals
†
.
17+,4-
CC2
M_CC_IO2
Camera control output 2 for acquisition path n, which supports: timer output
(M_TIMER1/M_TIMER2 on M_DEVn), user output
(M_USER_BIT_CC_IO0/M_USER_BIT_CC_IO1 on M_DEVn), VSYNC, HSYNC,
clock output, or rerouting of specific auxiliary input signals
†
.
20+,7-
SerTC
Serial port to video source (UART).
26
Inner shield
Ground (inner shield), or +12V to camera in PoCL mode.
section of
Chapter 4: Matrox Rapixo CL Pro hardware reference
for more information on which auxiliary
input signals (or auxiliary I/O signals set to input) can be rerouted onto the camera control output signals. Also note that for Matrox Rapixo CL
Pro DB and QB, n should be replaced by the number of the Camera Link connector to which the video source is connected.
Содержание Rapixo CL Pro
Страница 1: ...Matrox Rapixo CL Pro Installation and Hardware Reference Manual no Y11522 101 0100 August 7 2020...
Страница 6: ......
Страница 18: ...18 Chapter 1 Introduction...
Страница 64: ...64 Appendix A Glossary...
Страница 86: ...86 Appendix B Technical information...
Страница 95: ...Limited warranty Refer to the warranty statement that came with your product...
Страница 96: ......